All open City violation records (14)
No open City violation records dated in the last 24 months (since November 2024). The newest open one is from January 26, 2024. All 14 are collapsed below — still open, still counted.
Show 14 older open City violation records (before November 2024)
- Open
NC2011 — PLANS & PERMITS REQ - CONTRCTR
THIS INDUSTRIAL WAREHOUSE HAS BEEN THE SITE FOR HUGE ILLEGAL (FOR PROFIT) RAVE EVENTS FOR THE PAST YEAR. CPD HAS HAD AT LEAST A DOZEN CALLS FOR SERVICE. OWNERSHIP / MANAGEMENT IS COMPLETELY AWARE OF THESE EVENTS. THERE HAS BEEN NO BRAK INS TO THIS BUILDING WHATSOEVER. THE ILLEGAL PROPRIETORS EITHER HAVE KEYS TO THIS FACILITY OR ARE BEING ALLOWED ENTRY BY MANAGEMENT. THIS EVENT OF 1/26/24 WAS ATTENDED BY OVER 350 MONORS WITH TEENAGERS AS YOUNG AS 13 YEARS OLD. TICKETS ARE SOLD ONLINE WITH LIVE DJ MUSIC PROVIDED. ALCOHOL AND DRUG CONSUMPTION WAS RAMAPNT AT THIS OUT OF CONTROL, ILLEGAL EVENT.THERE ARE NO PLANS, PERMITS, ZONING AUTHORIZATION OR PPA LICENSE APPLICATIONS ON FILE TO ALLOW FOR ANY SUCH EVENT TO OCCUR IN THIS INDUSTRIAL WAREHOUSE.ALSO, EXTENSIVE WORK HAS BEEN PERFORMED TO SHORE UP THE ENORMOUS FIRST FLOOR AREA. IN THE BASEMENT, A LARGE AMOUNT OF NEW LUMBER IS IN PLACE TO SHORE UP THIS FLOOR. NO PLANS OR PERMITS ARE ON FILE FOR THIS EXTENSIVE WORK.SECTION 14A-4-401.1
- Open
CN103015 — REPAIR FLOOR
THE FIRST FLOOR OF THIS INDUSTRIAL BUILDING IS MISSING COLUMNS AND BEAMS THAT ONCE SUPPORTED THIS FLOOR SYSTEM. IN PLACE OF THE ORIGINAL COLUMN / BEAM SYSTEM IS A NEWLY CONSTRUCTED SUPPORT SYSTEM USING UNDERSIZED DIMENSIONAL LUMBER. NONE OF THE NEW STRUCTURAL COLUMS HAVE FOOTINGS. THIS SHORING CONFIGURATION WAS PERFORMED WITHOUT PLANS OR PERMITS.DANGEROUS AND HAZARDOUS.SECTION 14X-3-304.3 AND 14X-12-1202.5.2
- Open
NC2071 — WORK NOT ALLOWED
IN THE BASEMENT OF THIS INDUSTRIAL WAREHOUSE AN EXTENSIVE AMOUNT OF NEW CONSTRUCTION HAS OCCURRED WITH OUT PLANS / PERMITS. THE LUMBER USED IS ABSOLUTELY NEW / RECENT. NONE OF THE WORK PERFORMED WAS DONE WITH PERMIT BY LICENSED CONTRACTORS. THE WORKMANSHIP IS SUBSTANDARD; SO MUCH SO THE THE STRUCTURAL COLUMNS INSTALLED TO SUPPORT THE 1ST FLOOR HAVE NO STRUCTURAL FOOTINGS. ALL OF THIS WORK, AFTER PLANS / PERMITS / STRUCTURAL ENGINERS' REPORT HAVE BEEN SUBMITTED OFR REVIEW, WILL BE COMPLETELY REMOVED AND RE-DONE.SECTION 14A-4-401
- Open
CN061024 — SUBMIT 2 COPY STRUCTURAL RPT
THIS REPORT IS TO EXAMINE THE FORST FLOOR - FLOOR SYSTEM IN ITS' ENTIRETY. ALSO, THIS REPORT IS TO EXAMINE AND COMMENT ON THE DEFFICIENT STRUCTURAL WORK PERFORMED IN THE BASEMENT (TO SUPPORT THE 1ST FLOOR - FLOOR SYSTEM) WITHOUT PLANS / PERMITS.SECTION 14X-1-104.1
- Open
CN015062 — OBSTRUCTIONS IN EXIT WAY
AT THE TIME OF THIS INSPECTION, THERE WERE OVER 350 MINORS AT THE RAVE EVENT IN THIS INDUSTRIAL BUILDING. MOST OF THESE MINORS WERE DRINKING / CONSUMING DRUGS AND WERE IN AN ADVANCED STATE OF INTOXICATION. THERE WAS ONLY 1 FUNCTIONING (36") EXIT DOOR THAT WAS OPERABLE. THE OTHER DOORS WERE EITHER LOCKED OR BLOCKED BY OBSTRUCTIONS.EXTREME HAZARD.SECTION 14X-5-505.1.2
- Open
CN107035 — MAINTAIN EXIT SIGN ILLUMINATED
THIS INDUSTRIAL BUILDING HAS NO EXIT SIGNS.DANGEROUS AND HAZARDOUS.SECTION 14X-5-505.13
- Open
CN078014 — ILLUMINATE EXIT AREAS
THIS INDUSTRIAL BUILDING HAS BEEN HOSTING LARGE EVENTS WITHOUT LICENSE IN THIS FACILITY; WHICH HAS NO DEDICATED EXIT ILLUMINATION.DANGEROUS AND HAZARDOUS.SECTION 14X-12-1202.4.7
- Open
CN197089 — CARB MONOX DETECT IN ASSEMBLY
THIS INDUSTRIAL BUILDING / ILLEGAL EVENT SPACE HAS NO CARBON MONOXIDE DETECTORS.DANGEROUS AND HAZARDOUS.SECTION 14X-5-504.9
- Open
CN031033 — FIRE EXTNGSHR REQ, NONRESDNTL
THIS ILLEGAL EVENT SPACE HAS NO FIRE EXTINGUISHERS.DANGEROUS AND HAZARDOUS.SECTION 14X-5-504.5
- Open
CN197019 — INSTALL SMOKE DETECTORS
THIS ILLEGAL EVENT SPACE HAS NO SMOKE DETECTORS.DANGEROUS AND HAZARDOUS.SECTION 14X-5-504.8
- Heat-related
CN010012 — 1-HR HEATING PLANT ENCLOSURE
THE 1ST AND 2CD FLOOR OF THIS WAREHOUSE (HEAVY TIMBER CONSTRUCTION) HAS 2 LARGE, GAS FIRED HEATERS HUNG FROM THE CEILING. THE DISCHARGE OF SUPER HEATED AIR IS VENTED, ALONG WITH THE HEATER ENCLOSURE ITSELF, WITHIN 16" OF THE FLAMMABLE WOOD CEILINGS.DANGEROUS AND HAZARDOUS.SECTION 14X-5-509
- Open
CN140016 — DWELLING CLEAN AND SANITARY
THIS RAVE EVENT, ILLEGALLY HELD IN THIS INDUSTRIAL WAREHOUSE WITH 2 INOPERABLE TOILETS, CAUSED THE OVER 350 MINORS ATTENDEES TO URINATE AND DEFICATE OUTSIDE ON THE PUBLIC WAY.DANGEROUS AND HAZARDOUS.SECTION 14-1-103 AND 14X-12-1202.5.1
- Open
EL0029 — EXPOSED WIRING
THERE WAS EXPOSED ELECTRICAL MWIRING AT SEVERAL LOCATIONS IN THE ILLEGAL EVENT SPACE.DANGEROUS AND HAZARDOUS.SECTION 14X-7-703 / 705.
- Open
EL0016 — ADD RECEPTACLES
THIS ILLEGAL RAVE EVENT USED AN EXTENSIVE AMOUNT OF EXTENSION CORD WIRING.DANGEROUS AND HAZARDOUS.SECTION 14X-7-703 / 705
About these City violation records
From the City of Chicago Building Violations dataset description: “…informational only and does not necessarily reflect the current condition of the building or property. The dataset contains cases where a respondent has been found to be liable as well as cases where the respondent has been found to be not liable.”
311 complaints (24 months)
No matching 311 complaints in the last 24 months.
Timeline
- Open City violation record — EL0016 ADD RECEPTACLES
- Open City violation record — EL0029 EXPOSED WIRING
- Open City violation record — CN140016 DWELLING CLEAN AND SANITARY
- Open heat-related City violation record — CN010012 1-HR HEATING PLANT ENCLOSURE
- Open City violation record — CN197019 INSTALL SMOKE DETECTORS
- Open City violation record — CN031033 FIRE EXTNGSHR REQ, NONRESDNTL
- Open City violation record — CN197089 CARB MONOX DETECT IN ASSEMBLY
- Open City violation record — CN078014 ILLUMINATE EXIT AREAS
- Open City violation record — CN107035 MAINTAIN EXIT SIGN ILLUMINATED
- Open City violation record — CN015062 OBSTRUCTIONS IN EXIT WAY
- Open City violation record — CN061024 SUBMIT 2 COPY STRUCTURAL RPT
- Open City violation record — NC2071 WORK NOT ALLOWED
- Open City violation record — CN103015 REPAIR FLOOR
- Open City violation record — NC2011 PLANS & PERMITS REQ - CONTRCTR
Recently closed / other violations (sample)
No recent closed violations in the sample.
Around 1929 W Lake St
- Near West Side building violations and 311 complaints
- UIC off-campus housing: University Village renter guide
- No heat in your Chicago apartment? The heat ordinance and what to do
Nearby buildings with open City violation records
Nearby addresses that also have open City violation records in the City of Chicago Building Violations dataset (22u3-xenr), by distance. Open each one for its current free report.
How the winter score is calculated
- Start at 100 (better = higher).
- Minus up to 40 for open heat/boiler-related building violations (12 pts each).
- Minus up to 45 for other open building violations (2 pts each, plus extras above 20 and 100 open).
- Minus up to 20 for rodent-related open violations and 311 rodent complaints (4 pts each).
- Minus up to 15 for recent 311 building complaints (2 pts each).
- Extra −10 if 3+ open heat-related violations.
- Chicago 311 takes no-heat complaints, but the City's public 311 dataset does not publish them as a separate type, so heat here comes from open Department of Buildings heat-related violations (codes/descriptions, e.g. CN132016 HEAT UNIT ADEQUATELY). 311 building complaints are counted separately, not as heat.
- Public records only — not an inspection, appraisal, or legal advice.
Sources: City of Chicago Building Violations (data.cityofchicago.org/d/22u3-xenr); City of Chicago 311 Service Requests (data.cityofchicago.org/d/v6vf-nfxy). Data: City of Chicago (chicago.gov). Data as of November 21, 2026 at 9:01 AM CT.
ScoutMyBuilding summarizes publicly available City data. It is informational only — not legal advice, not a housing inspection, and not a guarantee of current building conditions. City records may be incomplete, delayed, or inaccurate. Always verify with the City of Chicago Department of Buildings, 311, and your own walkthrough before signing a lease.
“This site provides applications using data that has been modified for use from its original source, www.cityofchicago.org, the official website of the City of Chicago. The City of Chicago makes no claims as to the content, accuracy, timeliness, or completeness of any of the data provided at this site. The data provided at this site is subject to change at any time. It is understood that the data provided at this site is being used at one’s own risk.” Required by the City of Chicago Data Terms of Use.