Free building report
1840 N BISSELL ST
Winter habitability score Some issues on record — read the details
Renter reviews
Firsthand and anonymous. Renter opinions are separate from the city records below.
No renter reviews here yet. If you’ve lived at 1840 N Bissell St, yours could be the first.
Do you live here?
One tap helps other renters. The full building record stays right below.
Thanks for looking. The full record is right below.
No problem. The full record is right below.
Thanks, neighbor. Share how it’s really been — one tap on the stars is all it takes.
Thanks. Share how it really was — one tap on the stars is all it takes.
Sure, I’ll share
All open City violation records (13)
No open City violation records dated in the last 24 months (since November 2024). The newest open one is from September 4, 2012. All 13 are collapsed below — still open, still counted.
Show 13 older open City violation records (before November 2024)
- Open
CN070014 — REPAIR EXTERIOR STAIR
FRONT STAIRWAY - GRADE TO 1ST - COLUMNS ERECTED ON CONCRETE SLABS - FOUNDATION STATUS UNKOWN. BEAMS ONLY NAILED TO COLUMNS. LEDGER BEAM ONLY NAILED TO BUILDING. STRINGERS ONLY NAILED TO COLUMNS AND HEADER JOISTS. TREADS - LOOSE . GUARDRAILS ONLY 37'' HIGH. STAIR RAILS - MISSING . SOUTHEAST STAIRWAY - GRADE TO BASEMENT - HANDRAILS - MISSING. WEST BASEMENT STAIRWAY - GRADE TO BASEMENT - HANDRAIL - MISSING.
- Open
EL0064 — SERVICE DROP OUT OF REACH
REAR DECK AT 2ND - ELECTRICAL SERVICE CONDUCTOR WITHIN 1' OF DECK - NOT OUT OF REACH - ELECTROCUTION HAZARD.
- Open
CN138106 — STOP/REMOVE NUISANCE
REAR DECK AT 2ND - FULL OF DEBRIS. REAR DECK AT 2ND - CONDENSATE PIPE LEAKING RUSTY WATER ON WALL AND WINDOW. 3 ELECTRICAL METERS 3 APARTMENTS - MISSING BUILDING ELECTRICAL METER - PERMIT REQUIRED FOR INSTLLING BUILDING ELECTRIC METER.
- Open
CN071014 — REPAIR EXTERIOR PLATFORM
REAR 2 STORY DECK - COLUMNS ERECTED ON CONCRETE SLABS - FOUNDATION STATUS UNKNOWN. BEAMS TO COLUMNS - ONLY NAILED . SINGLE 2 X 10 BEAM CARRYING 2ND LEVEL DECK. GUARDRAILS LOOSE. PARKING BOLARDS - MISSING FOR VEHICLE PROTECTION OF COLUMNS. PERMIT ONLY REQUIRED FOR REPAIRS.
- Open
CN197079 — REPAIR/REPLACE SMOKE DETECTORS
1ST FLOOR SMOKE DETECTOR - OUT OF SERVICE.
- Open
CN197019 — INSTALL SMOKE DETECTORS
TOP OF FRONT AND REAR STAIRWAYS - SMOKE DETECTORS - MISSING. BASEMENT APARTMENT - SMOKE DETECTOR - MISSING.
- Open
CN014012 — NO CLOSET/STORAGE UNDER STAIR
FRONT BASEMENT CLOSET UNDER STAIRS - STORING CLOTHES AND PERSONAL ITEMS. REAR BASEMENT CLOSET - LAUNDRY WASHER AND DRYER STORED - FIRE HAZARDS.
- Open
CN197087 — CARB MONOX DETECT IN RESID
1ST FLOOR - APARTMENT - MISSING CARBON MONOXIDE DETECTOR.
- Open
NC2011 — PLANS & PERMITS REQ - CONTRCTR
SUBMIT PLANS AND OBTAIN PERMIT FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS TO BASEMENT AND 2ND FLOOR APARTMENTS OR RESTORE BUILDING TO THE ORIGINAL STATE.
- Open
NC2071 — WORK NOT ALLOWED
REMOVE ALL PARTITIONS AND FIXTURES [ INCLUDING PLUMBING AND ELECTRIC ] INSTALLED IN THE BASEMENT AND 2ND FLOOR WITHOUT A PERMIT.
- Open
PL157047 — STOP LEAKING WATER
BASEMENT BATHROOM CEILING - LEAKING WATER. 1ST FLOOR APARTMENT - KITCHEN CEILING - LEAKING WATER.
- Open
CN140016 — DWELLING CLEAN AND SANITARY
BASEMENT APARTMENT - KITCHEN , UNDER SINK - MILDEW AND UNSANITARY CONDITIONS. BATHROOM - MILDEWED THROUGHOUT. BASEMENT UNDER STAIRS AT WALLS - MILDEW AND UNSANITARY CONDITIONS.
- Open
CN102015 — INT WALL/CEILING PEELING PAINT
BASEMENT - BATHROOM CEILING - WATER STAINED , BUBBLED PLASTER , AND PEELING PAINT. 1ST FLOOR KITCHEN - WATER STAINED , BUBBLED PLASTER , AND PEELING PAINT.
About these City violation records
From the City of Chicago Building Violations dataset description: “…informational only and does not necessarily reflect the current condition of the building or property. The dataset contains cases where a respondent has been found to be liable as well as cases where the respondent has been found to be not liable.”
311 complaints (24 months)
No matching 311 complaints in the last 24 months.
Timeline
- Open City violation record — CN102015 INT WALL/CEILING PEELING PAINT
- Open City violation record — CN140016 DWELLING CLEAN AND SANITARY
- Open City violation record — PL157047 STOP LEAKING WATER
- Open City violation record — NC2071 WORK NOT ALLOWED
- Open City violation record — NC2011 PLANS & PERMITS REQ - CONTRCTR
- Open City violation record — CN197087 CARB MONOX DETECT IN RESID
- Open City violation record — CN014012 NO CLOSET/STORAGE UNDER STAIR
- Open City violation record — CN197019 INSTALL SMOKE DETECTORS
- Open City violation record — CN197079 REPAIR/REPLACE SMOKE DETECTORS
- Open City violation record — CN071014 REPAIR EXTERIOR PLATFORM
- Open City violation record — CN138106 STOP/REMOVE NUISANCE
- Open City violation record — EL0064 SERVICE DROP OUT OF REACH
- Open City violation record — CN070014 REPAIR EXTERIOR STAIR
Recently closed / other violations (sample)
- Closed / other
CN076034 REPAIR GUTTER
- Closed / other
CN104015 REPLCE WINDOW PANES, PLEXGLAS
- Closed / other
CN131016 SCREEN OUTER DOORS, WINDOWS
- Closed / other
CN106015 REPAIR INTERIOR STAIR SYSTEM
- Closed / other
EL0036 COVER OUTLETS AND JBS
- Closed / other
PL159027 RESET LOOSE FIXTURE
Around 1840 N Bissell St
- Lincoln Park building violations and 311 complaints
- DePaul off-campus housing: Lakeview and Lincoln Park renter guide
Nearby buildings with open City violation records
Nearby addresses that also have open City violation records in the City of Chicago Building Violations dataset (22u3-xenr), by distance. Open each one for its current free report.
How the winter score is calculated
- Start at 100 (better = higher).
- Minus up to 40 for open heat/boiler-related building violations (12 pts each).
- Minus up to 45 for other open building violations (2 pts each, plus extras above 20 and 100 open).
- Minus up to 20 for rodent-related open violations and 311 rodent complaints (4 pts each).
- Minus up to 15 for recent 311 building complaints (2 pts each).
- Extra −10 if 3+ open heat-related violations.
- Chicago 311 takes no-heat complaints, but the City's public 311 dataset does not publish them as a separate type, so heat here comes from open Department of Buildings heat-related violations (codes/descriptions, e.g. CN132016 HEAT UNIT ADEQUATELY). 311 building complaints are counted separately, not as heat.
- Public records only — not an inspection, appraisal, or legal advice.
Sources: City of Chicago Building Violations (data.cityofchicago.org/d/22u3-xenr); City of Chicago 311 Service Requests (data.cityofchicago.org/d/v6vf-nfxy). Data: City of Chicago (chicago.gov). Data as of November 21, 2026 at 7:21 AM CT.
ScoutMyBuilding summarizes publicly available City data. It is informational only — not legal advice, not a housing inspection, and not a guarantee of current building conditions. City records may be incomplete, delayed, or inaccurate. Always verify with the City of Chicago Department of Buildings, 311, and your own walkthrough before signing a lease.
“This site provides applications using data that has been modified for use from its original source, www.cityofchicago.org, the official website of the City of Chicago. The City of Chicago makes no claims as to the content, accuracy, timeliness, or completeness of any of the data provided at this site. The data provided at this site is subject to change at any time. It is understood that the data provided at this site is being used at one’s own risk.” Required by the City of Chicago Data Terms of Use.