1704 W Juneway Ter

Winter habitability score Many open City violation records and/or complaint activity

Download a PDF of this report

Renter reviews

Firsthand and anonymous. Renter opinions are separate from the city records below.

No renter reviews here yet. If you’ve lived at 1704 W Juneway Ter, yours could be the first.

A Chicago three-flat

Do you live here?

One tap helps other renters. The full building record stays right below.

Sure, I’ll share
How’s it been living here? Required

Tap a star — 1 is rough, 5 is great.

Add more detail (optional — heat, pests, repairs, noise, management)

Tap 1 to 5 for any you want. 1 is rough, 5 is great. Skip the rest.

Heat Warm enough when it counts?
Pests Have pests been a problem?
Maintenance responsiveness When something broke, how fast did it get fixed?
Noise How noisy was it, day to day?
Management How they treated you and answered you
Would you rent here again?

Your own experience only — no fake or paid reviews. Shown anonymously after you confirm and a person approves it. Review policy · Terms

12Open City violation records
3Open heat-related City records
1311 rodent (24 mo)
0311 building (24 mo)

What rat complaints mean →

All open City violation records (12)

No open City violation records dated in the last 24 months (since November 2024). The newest open one is from December 18, 2019. All 12 are collapsed below — still open, still counted.

Show 12 older open City violation records (before November 2024)
  • Open

    CN190029 — ARRANGE FOR REINSPECTION REGAR

    INTERIOR OF BUILDING /NO RESPONSE. UNVERIFIED DETECTORS AND CONDITIONS. UNVERIFIED COMPLAINT OF RODENT AND PEST INFESTATION.

  • Heat-related

    CN132016 — HEAT UNIT ADEQUATELY

    64 DEGREES IN APARTMENT 1E.

  • Open

    CN190019 — ARRANGE PREMISE INSPECTION

    INTERIOR OF BUILDING- NO RESPONSE,UNVERIFIED DETECTORS AND CONDITIONS.

  • Open

    CN198019 — FILE BLDG REGISTRATION

    BUILDING NOT REGISTERED FOR 2017.

  • Heat-related

    CN132016 — HEAT UNIT ADEQUATELY

    #1704 APT. 1E - ROOM TEMPERATURES WERE 59-61 DEGREES AT TIME OF INSPECTION; INSUFFICIENT HEAT PROVIDED

  • Heat-related

    CN132016 — HEAT UNIT ADEQUATELY

    INADEQUATE HEAT.

  • Rodent-related

    CN136016 — ROACHES

    APARTMENT 3F -ROACHES THRU-OUT APARTMENT.

  • Open

    CN136026 — INSECTS

    APARTMENT 3F - INSECTS THRU-OUT APARTMENT

  • Open

    CN062024 — PARAPET

    NORTH ELEVATION AT EAST END SHIFTING BRICK, SPALLED BRICK AND ERODING MORTAR. VARIOUS LOCATIONS NORTH WITH ERODING MORTAR AND SPALLING BRICK.

  • Open

    CN070034 — REPLACE D&H PORCH

    EAST PORCH, LINTELS AT SOUTH END SERVING AS SUPPORT FOR JOISTS IN MASONRY POCKETS, RUSTED AND SAGGING, SPALLING AND LOOSE BRICK WITH ERODED MORTAR AND INSUFFICIENT JOIST SUPPORT DUE TO DETERIORATING CONDITIONS. 6X6 LOOKOUT BEAMS WITH INSUFFICIENT ANCHORING TO MASONRY AT NUMEROUS LOCATIONS. ALSO LOOKOUT BEAMS IN MASONRY POCKETS WITH LOOSE MASONRY AND MISSING MORTAR. COLUMNS AT NUMEROUS LOCATIONS THRU-OUT WITH FIRE CUTS, LAPP JOINTS AND BOLTS FOR ANGLE IRONS IN CLOSE PROXIMITY. UNDER 1, 3RD COLUMN AND LOOKOUT BEAM IN FROM SOUTH WITH SIGNIFICANT ROTT AT FIRE CUT. INSUFFICIENT BEAM AND COLUMN CONNECTIONS AT STAIRS. COLUMN WITH ROTT AT LANDING BEFORE 1. PARTIAL PLYWOOD ENCLOSURE NOT PERMITED AND NOT ALLOWED BY CODE. ROTTING COLUMN UNDER 2 AT SOUTH END. ROTTING BEAM AND COLUMN AT CONNECTION UNDER 2 SECOND COLUMN IN FROM SOUTH END. ROTTING BUTT JOINT COLUMN AND CONNECTION AT LOOKOUT BEAM UNDER 2, 3RD COLUMN FROM NORTH END. INSUFFICIENT PORCH ROOF BEAM TO COLUMN CONNECTIONS. ROTTING COLUMN AT 3 NORTH END. LOOSE DECKING AT 3. ROTTING COLUMN AT 3, 3RD COLUMN IN FROM NORTH END. SEVERAL LOCATIONS WHERE GUARD RAILS SECURED TO ROTTING COLUMNS AT BOTTOM OF RAILING. OBTAIN COMPLETE PLANS AND PERMIT FOR PORCH WORK.

  • Open

    CN063014 — CHIMNEY

    CHIMNEY WITH FRACTURES AND ERODING MORTAR.

  • Open

    CN061014 — REPAIR EXTERIOR WALL

    SOUTH ELEVATION AT 1700, 3RD FLOOR WITH FRACTURES OFF LINTEL.

About these City violation records

From the City of Chicago Building Violations dataset description: “…informational only and does not necessarily reflect the current condition of the building or property. The dataset contains cases where a respondent has been found to be liable as well as cases where the respondent has been found to be not liable.”

↑ Back to renter reviews

311 complaints (24 months)

  • rodent

    Rodent Baiting/Rat Complaint

Timeline

  1. 311 rodent — Rodent Baiting/Rat Complaint
  2. Open City violation record — CN190029 ARRANGE FOR REINSPECTION REGAR
  3. Open heat-related City violation record — CN132016 HEAT UNIT ADEQUATELY
  4. Open City violation record — CN198019 FILE BLDG REGISTRATION
  5. Open City violation record — CN190019 ARRANGE PREMISE INSPECTION
  6. Open heat-related City violation record — CN132016 HEAT UNIT ADEQUATELY
  7. Open heat-related City violation record — CN132016 HEAT UNIT ADEQUATELY
  8. Open City violation record — CN136026 INSECTS
  9. Open City violation record — CN136016 ROACHES
  10. Open City violation record — CN061014 REPAIR EXTERIOR WALL
  11. Open City violation record — CN063014 CHIMNEY
  12. Open City violation record — CN070034 REPLACE D&H PORCH
  13. Open City violation record — CN062024 PARAPET

Recently closed / other violations (sample)

  • Closed / other

    CN198019 FILE BLDG REGISTRATION

  • Closed / other

    CN190019 ARRANGE PREMISE INSPECTION

  • Closed / other

    CN106015 REPAIR INTERIOR STAIR SYSTEM

  • Closed / other

    CN197079 REPAIR/REPLACE SMOKE DETECTORS

  • Closed / other

    CN061014 REPAIR EXTERIOR WALL

  • Closed / other

    CN062014 PARAPET & COPING

  • Closed / other

    CN131026 REPAIR SCREENS

Around 1704 W Juneway Ter

Nearby buildings with open City violation records

Nearby addresses that also have open City violation records in the City of Chicago Building Violations dataset (22u3-xenr), by distance. Open each one for its current free report.

How the winter score is calculated
  1. Start at 100 (better = higher).
  2. Minus up to 40 for open heat/boiler-related building violations (12 pts each).
  3. Minus up to 45 for other open building violations (2 pts each, plus extras above 20 and 100 open).
  4. Minus up to 20 for rodent-related open violations and 311 rodent complaints (4 pts each).
  5. Minus up to 15 for recent 311 building complaints (2 pts each).
  6. Extra −10 if 3+ open heat-related violations.
  7. Chicago 311 takes no-heat complaints, but the City's public 311 dataset does not publish them as a separate type, so heat here comes from open Department of Buildings heat-related violations (codes/descriptions, e.g. CN132016 HEAT UNIT ADEQUATELY). 311 building complaints are counted separately, not as heat.
  8. Public records only — not an inspection, appraisal, or legal advice.

Sources: City of Chicago Building Violations (data.cityofchicago.org/d/22u3-xenr); City of Chicago 311 Service Requests (data.cityofchicago.org/d/v6vf-nfxy). Data: City of Chicago (chicago.gov). Data as of November 21, 2026 at 9:45 AM CT.

ScoutMyBuilding summarizes publicly available City data. It is informational only — not legal advice, not a housing inspection, and not a guarantee of current building conditions. City records may be incomplete, delayed, or inaccurate. Always verify with the City of Chicago Department of Buildings, 311, and your own walkthrough before signing a lease.

“This site provides applications using data that has been modified for use from its original source, www.cityofchicago.org, the official website of the City of Chicago. The City of Chicago makes no claims as to the content, accuracy, timeliness, or completeness of any of the data provided at this site. The data provided at this site is subject to change at any time. It is understood that the data provided at this site is being used at one’s own risk.” Required by the City of Chicago Data Terms of Use.