Free building report

1641 W HARRISON ST

Winter habitability score Some issues on record — read the details

Download a PDF of this report

Renter reviews

Firsthand and anonymous. Renter opinions are separate from the city records below.

No renter reviews here yet. If you’ve lived at 1641 W Harrison St, yours could be the first.

A Chicago three-flat

Do you live here?

One tap helps other renters. The full building record stays right below.

Sure, I’ll share
How’s it been living here? Required

Tap a star — 1 is rough, 5 is great.

Add more detail (optional — heat, pests, repairs, noise, management)

Tap 1 to 5 for any you want. 1 is rough, 5 is great. Skip the rest.

Heat Warm enough when it counts?
Pests Have pests been a problem?
Maintenance responsiveness When something broke, how fast did it get fixed?
Noise How noisy was it, day to day?
Management How they treated you and answered you
Would you rent here again?

Your own experience only — no fake or paid reviews. Shown anonymously after you confirm and a person approves it. Review policy · Terms

14Open City violation records
0Open heat-related City records
0311 rodent (24 mo)
0311 building (24 mo)

What rat complaints mean →

All open City violation records (14)

No open City violation records dated in the last 24 months (since November 2024). The newest open one is from December 22, 2021. All 14 are collapsed below — still open, still counted.

Show 14 older open City violation records (before November 2024)
  • Open

    CN061024 — SUBMIT 2 COPY STRUCTURAL RPT

    SUBMIT CONDITION ASSESSMENT REPORT FOR THE ENTIRE PARKING STRUCTURE INCLUDING, BUT NOT LIMITED TO ALL SPALLING AND CRACKED CONCRETE AND EXPOSED RUSTED STRUCTURAL STEEL REINFORCEMENT BARS AND WEST END NEAR STAIRWELL C AND ADJACENT ELEVATOR 73 - REPORT SHALL BE SIGNED AND SEALED BY A REGISTERED DESIGN PROFESSIONAL, AND BASED ON A CRITICAL, COMPREHENSIVE, AND DETAILED PHYSICAL INSPECTION OF THE PREMISES IDENTIFIED AND DETAILED IN THE VIOLATION - THE REPORT MUST IDENTIFY THE DATE, NATURE, SCOPE, FINDINGS, AND DEFICIENCIES OF THE INSPECTION/INVESTIGATION - THE REPORT MUST IDENTIFY EACH TECHNICAL PRINCIPLE OR STANDARD THAT IS THE BASIS OF ANY PROFESSIONAL JUDGMENT AND COMPREHENSIVE RECOMMENDATIONS FOR REPAIRS EXPRESSED IN THE REPORT - RECOMMENDATION OF REPAIRS MUST INCLUDE PHOTOS, DRAWINGS, DETAILS, AND CALCULATIONS WHICH MAY BE USED TO SUBMITTED FOR A REPAIR PERMIT WHEN ALLOWED - THE CONDITION REPORT, PERMIT, AND PERMITTED DRAWINGS MUST BE KEPT ON FILE AT THE PROPERTY AND MADE AVAILABLE FOR FIELD INSPECTION REVIEW AND APPROVAL BY ALL RELATED TRADES - SUBMIT ELECTRONIC REPORT FOR REVIEW AND APPROVAL TO: DOB_CAR@CITYOFCHICAGO.ORG (14X-1-104.1 THRU 14X-1-104.4, 14A-6-603.5, AND 14A-4-411.1)

  • Open

    EV1110 — MAINTAIN OR REPAIR ELECT ELEVA

    ANTI ROTATION DEVICES ON COUNTER WEIGHT HOIST ROPE SHACKLES

  • Open

    EV1110 — MAINTAIN OR REPAIR ELECT ELEVA

    COTTER PINS ON TOP AND BOTTOM OF COUNTERWEIGHT RODS

  • Open

    EV1110 — MAINTAIN OR REPAIR ELECT ELEVA

    DUCT AND ELECTRICITY BOX COVERS HOISTWAY AND MACHINE ROOM

  • Open

    EV1110 — MAINTAIN OR REPAIR ELECT ELEVA

    PROVIDE MACHINE ROOM LIGHTING W/ MECHANICAL PROTECTION OF BULBS

  • Open

    EV1110 — MAINTAIN OR REPAIR ELECT ELEVA

    PROVIDE GFCL OUTLETS IN ALL MACHINE SPACES IN MACHINE ROOM

  • Open

    EV1110 — MAINTAIN OR REPAIR ELECT ELEVA

    PROVIDE DISCONNECTS FOR LINE AND 110V CAB POWER WITH LINE OF SIGHT

  • Open

    EV1110 — MAINTAIN OR REPAIR ELECT ELEVA

    PROVIDE KICK GUARDS AROUND CABLE SLOTS

  • Open

    EV1110 — MAINTAIN OR REPAIR ELECT ELEVA

    PROVIDE HVAC IN MACHINE ROOM

  • Open

    EV1110 — MAINTAIN OR REPAIR ELECT ELEVA

    PROVIDE FAID RECALL W/ ELEVATOR CONTROPANEL HIGH RISE. CODE OVER 80FT

  • Open

    EV1110 — MAINTAIN OR REPAIR ELECT ELEVA

    PROVIDE CAR NUMBERS ON ALL HOISTWAY OPENINGS AT ALL FLOORS

  • Open

    EV1110 — MAINTAIN OR REPAIR ELECT ELEVA

    PROVIDE LIGHTING W/ MECHANICAL PROTECTION OF BULBS AND GFCL OUTLETS IN PITS

  • Open

    EV1110 — MAINTAIN OR REPAIR ELECT ELEVA

    UPON COMPLIANCE OF ABOVE RELOCATIONS AND COMPLETION OF THE MODERNIZATION OF ALL THREE ELEVATORS CONTACT THE ELEVATOR BUREAU OF THE CITY OF CHICAGO TO SCHEDULE FIREMAN'S RECALL AND FINAL INSPECTIONS

  • Open

    CN061000 — LIFE SAFETY EVALUATION PLAN

    LIFE SAFETY EVALUATION DUE JANUARY 1, 2006 HAS NOT BEEN SUBMITTED AS OF JUNE 20, 20056 CALL JOSE APARICIO 312/743-7266

About these City violation records

From the City of Chicago Building Violations dataset description: “…informational only and does not necessarily reflect the current condition of the building or property. The dataset contains cases where a respondent has been found to be liable as well as cases where the respondent has been found to be not liable.”

↑ Back to renter reviews

311 complaints (24 months)

No matching 311 complaints in the last 24 months.

Timeline

  1. Open City violation record — CN061024 SUBMIT 2 COPY STRUCTURAL RPT
  2. Open City violation record — EV1110 MAINTAIN OR REPAIR ELECT ELEVA
  3. Open City violation record — EV1110 MAINTAIN OR REPAIR ELECT ELEVA
  4. Open City violation record — EV1110 MAINTAIN OR REPAIR ELECT ELEVA
  5. Open City violation record — EV1110 MAINTAIN OR REPAIR ELECT ELEVA
  6. Open City violation record — EV1110 MAINTAIN OR REPAIR ELECT ELEVA
  7. Open City violation record — EV1110 MAINTAIN OR REPAIR ELECT ELEVA
  8. Open City violation record — EV1110 MAINTAIN OR REPAIR ELECT ELEVA
  9. Open City violation record — EV1110 MAINTAIN OR REPAIR ELECT ELEVA
  10. Open City violation record — EV1110 MAINTAIN OR REPAIR ELECT ELEVA
  11. Open City violation record — EV1110 MAINTAIN OR REPAIR ELECT ELEVA
  12. Open City violation record — EV1110 MAINTAIN OR REPAIR ELECT ELEVA
  13. Open City violation record — EV1110 MAINTAIN OR REPAIR ELECT ELEVA
  14. Open City violation record — CN061000 LIFE SAFETY EVALUATION PLAN

Recently closed / other violations (sample)

  • Closed / other

    EV1111 MAINTAIN OR REPAIR HYDRO ELEVA

  • Closed / other

    EV1111 MAINTAIN OR REPAIR HYDRO ELEVA

  • Closed / other

    EV1111 MAINTAIN OR REPAIR HYDRO ELEVA

  • Closed / other

    EV1111 MAINTAIN OR REPAIR HYDRO ELEVA

  • Closed / other

    EV1111 MAINTAIN OR REPAIR HYDRO ELEVA

  • Closed / other

    EV1111 MAINTAIN OR REPAIR HYDRO ELEVA

  • Closed / other

    EV1111 MAINTAIN OR REPAIR HYDRO ELEVA

  • Closed / other

    EV1111 MAINTAIN OR REPAIR HYDRO ELEVA

  • Closed / other

    EV1111 MAINTAIN OR REPAIR HYDRO ELEVA

  • Closed / other

    EV1111 MAINTAIN OR REPAIR HYDRO ELEVA

  • Closed / other

    EV1111 MAINTAIN OR REPAIR HYDRO ELEVA

  • Closed / other

    EV1111 MAINTAIN OR REPAIR HYDRO ELEVA

Around 1641 W Harrison St

Nearby buildings with open City violation records

Nearby addresses that also have open City violation records in the City of Chicago Building Violations dataset (22u3-xenr), by distance. Open each one for its current free report.

How the winter score is calculated
  1. Start at 100 (better = higher).
  2. Minus up to 40 for open heat/boiler-related building violations (12 pts each).
  3. Minus up to 45 for other open building violations (2 pts each, plus extras above 20 and 100 open).
  4. Minus up to 20 for rodent-related open violations and 311 rodent complaints (4 pts each).
  5. Minus up to 15 for recent 311 building complaints (2 pts each).
  6. Extra −10 if 3+ open heat-related violations.
  7. Chicago 311 takes no-heat complaints, but the City's public 311 dataset does not publish them as a separate type, so heat here comes from open Department of Buildings heat-related violations (codes/descriptions, e.g. CN132016 HEAT UNIT ADEQUATELY). 311 building complaints are counted separately, not as heat.
  8. Public records only — not an inspection, appraisal, or legal advice.

Sources: City of Chicago Building Violations (data.cityofchicago.org/d/22u3-xenr); City of Chicago 311 Service Requests (data.cityofchicago.org/d/v6vf-nfxy). Data: City of Chicago (chicago.gov). Data as of November 21, 2026 at 8:30 AM CT.

ScoutMyBuilding summarizes publicly available City data. It is informational only — not legal advice, not a housing inspection, and not a guarantee of current building conditions. City records may be incomplete, delayed, or inaccurate. Always verify with the City of Chicago Department of Buildings, 311, and your own walkthrough before signing a lease.

“This site provides applications using data that has been modified for use from its original source, www.cityofchicago.org, the official website of the City of Chicago. The City of Chicago makes no claims as to the content, accuracy, timeliness, or completeness of any of the data provided at this site. The data provided at this site is subject to change at any time. It is understood that the data provided at this site is being used at one’s own risk.” Required by the City of Chicago Data Terms of Use.

Check another address

Help: hello@scoutmybuilding.com