Free building report

1635 E 53RD ST

Winter habitability score Multiple habitability signals in public records

Download a PDF of this report

Renter reviews

Firsthand and anonymous. Renter opinions are separate from the city records below.

No renter reviews here yet. If you’ve lived at 1635 E 53rd St, yours could be the first.

A Chicago three-flat

Do you live here?

One tap helps other renters. The full building record stays right below.

Sure, I’ll share
How’s it been living here? Required

Tap a star — 1 is rough, 5 is great.

Add more detail (optional — heat, pests, repairs, noise, management)

Tap 1 to 5 for any you want. 1 is rough, 5 is great. Skip the rest.

Heat Warm enough when it counts?
Pests Have pests been a problem?
Maintenance responsiveness When something broke, how fast did it get fixed?
Noise How noisy was it, day to day?
Management How they treated you and answered you
Would you rent here again?

Your own experience only — no fake or paid reviews. Shown anonymously after you confirm and a person approves it. Review policy · Terms

15Open City violation records
0Open heat-related City records
1311 rodent (24 mo)
0311 building (24 mo)

What rat complaints mean →

All open City violation records (15)

No open City violation records dated in the last 24 months (since November 2024). The newest open one is from April 21, 2011. All 15 are collapsed below — still open, still counted.

Show 15 older open City violation records (before November 2024)
  • Open

    CN190019 — ARRANGE PREMISE INSPECTION

    NO ENTRY. UNVERIIFED DETECTORS AND CONDITIONS.

  • Open

    CN063014 — CHIMNEY

    CHIMNEY LOOSE BRICKS OPEN JOINTS

  • Open

    CN101015 — REPAIR INTERIOR WALLS/CEILING

    1637 - 3RD FLOOR APARTMENT CRACKS,FRACTURED PLASTER- WALLS,CEILINGS.

  • Open

    CN138056 — DEBRIS, EXCESSIVE

    JUNK & DEBRIS ALL REAR PORCH LANDINGS - EXCESSIVE.

  • Open

    CN070024 — REPAIR PORCH SYSTEM

    1637- REAR PORCH- LOOKOUTS DISCONNECTED AT COLUMN CONNECTIONS / JOIST HANGERS MISSING,VARIOUS LOCATIONS/ STAIR STRINGERSNOT PROPERLY CONNECTED TO WALLS THRU-OUT 4X4 UNDER SIZE COLLUMNS GROUND TO 3RD FLOOR 6X6 SITTING ON SIDEWALK,ON BLOCKS-FOUNDATIONS UNKNOWN 10" SERVICE AT 6X6 COLUMNS.5309-11 PORCHES TYPICAL OONSTRUCTION IMPROPER FOOTINGS 6X6 ON SIDE WALKS,OR ON BLOCKS / LEDGERS NOT CONNECTED PROPERLY OPEN POCKETS,4X4 COLUMNS OVER 12 FEET SPLICES 10"-2 BOLTS NO JOIST HANGERS & RUSTED THRU DECKING- WORN,SPLIT & HOLES,VARIOUS LOCATIONS CANTILEVER LANDINGS ON STAIRS WITH RUST ANGIE SUPPORTS - GUARDRAILS OVER SPANNED & NOT CONNECTED TO BUILDING WALLS / NO STEEL STRAPS THRU OUT / JOIST OVER SPANNED 2X8X14 FEET.

  • Open

    NC2011 — PLANS & PERMITS REQ - CONTRCTR

    PLANS & PERMITS REQUIRED FOR REAR PORCHES

  • Rodent-related

    CN134016 — RATS

    802353005- BASEMENT EVIDENCE OF RATS DROPPINGS (1637 AND CONTINUES TO CORNELL

  • Rodent-related

    CN134036 — RAT PROOF OPENINGS

    OPENINGS AROUND PIPES BOILER ROOM 1637

  • Open

    CN138056 — DEBRIS, EXCESSIVE

    1637 BASEMENT UNSANITARY

  • Open

    CN061034 — FLAKY INTERIOR PAINT

    WINDOW TRIM FLAKING PAINT

  • Rodent-related

    CN134066 — RAT PROOF EXTERIOR DOOR

    1637 BASEMENT DOOR GAPS UNDERNEATH

  • Open

    PL161017 — REMV RARELY USED FIXTURE

    BASEMENT PIPES ALONG PERIMETER OF WALL OPEN NOT CAPPED.

  • Open

    CN190019 — ARRANGE PREMISE INSPECTION

    INTERIOR OF BUILDING-NO RESPONSE-UNVERIFIED DETECTORS. UNABLE TO VERIFY COMPLAINT FROM 1637-EAST REGARDING"MICE" UNABLE TO INSPECT FRONT INTERIOR STAIRWAY . UNABLE TO INSPECT REAR PORCHES.

  • Open

    CN070014 — REPAIR EXTERIOR STAIR

    (SR#801197622)5309 S. FRONT STAIRS GRADE TO BASEMENT-FLOOR DRAIN STRAINER MISSING.

  • Open

    CN015012 — NO KEY TO USE EXIT DOOR

    NORTH IRON GATE KEY LOCK.

About these City violation records

From the City of Chicago Building Violations dataset description: “…informational only and does not necessarily reflect the current condition of the building or property. The dataset contains cases where a respondent has been found to be liable as well as cases where the respondent has been found to be not liable.”

↑ Back to renter reviews

311 complaints (24 months)

  • rodent

    Rodent Baiting/Rat Complaint

Timeline

  1. 311 rodent — Rodent Baiting/Rat Complaint
  2. Open City violation record — CN190019 ARRANGE PREMISE INSPECTION
  3. Open City violation record — NC2011 PLANS & PERMITS REQ - CONTRCTR
  4. Open City violation record — CN070024 REPAIR PORCH SYSTEM
  5. Open City violation record — CN138056 DEBRIS, EXCESSIVE
  6. Open City violation record — CN101015 REPAIR INTERIOR WALLS/CEILING
  7. Open City violation record — CN063014 CHIMNEY
  8. Open City violation record — PL161017 REMV RARELY USED FIXTURE
  9. Open City violation record — CN134066 RAT PROOF EXTERIOR DOOR
  10. Open City violation record — CN061034 FLAKY INTERIOR PAINT
  11. Open City violation record — CN138056 DEBRIS, EXCESSIVE
  12. Open City violation record — CN134036 RAT PROOF OPENINGS
  13. Open City violation record — CN134016 RATS
  14. Open City violation record — CN070014 REPAIR EXTERIOR STAIR
  15. Open City violation record — CN190019 ARRANGE PREMISE INSPECTION
  16. Open City violation record — CN015012 NO KEY TO USE EXIT DOOR

Recently closed / other violations (sample)

  • Closed / other

    CN105045 INSTALL DEAD BOLT LOCK

  • Closed / other

    CN197087 CARB MONOX DETECT IN RESID

  • Closed / other

    CN015062 OBSTRUCTIONS IN EXIT WAY

  • Closed / other

    CN105045 INSTALL DEAD BOLT LOCK

  • Closed / other

    CN132046 SAFE WORKING CONDITIONS

  • Closed / other

    CN015062 OBSTRUCTIONS IN EXIT WAY

  • Closed / other

    CN197079 REPAIR/REPLACE SMOKE DETECTORS

  • Closed / other

    CN197079 REPAIR/REPLACE SMOKE DETECTORS

  • Closed / other

    CN197087 CARB MONOX DETECT IN RESID

  • Closed / other

    CN101015 REPAIR INTERIOR WALLS/CEILING

  • Closed / other

    CN063014 CHIMNEY

  • Closed / other

    CN101015 REPAIR INTERIOR WALLS/CEILING

  • Closed / other

    CN138056 DEBRIS, EXCESSIVE

  • Closed / other

    CN070024 REPAIR PORCH SYSTEM

  • Closed / other

    NC2011 PLANS & PERMITS REQ - CONTRCTR

  • Closed / other

    CN134066 RAT PROOF EXTERIOR DOOR

  • Closed / other

    CN134016 RATS

  • Closed / other

    CN134036 RAT PROOF OPENINGS

  • Closed / other

    CN138056 DEBRIS, EXCESSIVE

  • Closed / other

    CN061034 FLAKY INTERIOR PAINT

  • Closed / other

    PL161017 REMV RARELY USED FIXTURE

  • Closed / other

    CN190019 ARRANGE PREMISE INSPECTION

  • Closed / other

    CN197087 CARB MONOX DETECT IN RESID

  • Closed / other

    CN197019 INSTALL SMOKE DETECTORS

  • Closed / other

    CN190019 ARRANGE PREMISE INSPECTION

Around 1635 E 53rd St

Nearby buildings with open City violation records

Nearby addresses that also have open City violation records in the City of Chicago Building Violations dataset (22u3-xenr), by distance. Open each one for its current free report.

How the winter score is calculated
  1. Start at 100 (better = higher).
  2. Minus up to 40 for open heat/boiler-related building violations (12 pts each).
  3. Minus up to 45 for other open building violations (2 pts each, plus extras above 20 and 100 open).
  4. Minus up to 20 for rodent-related open violations and 311 rodent complaints (4 pts each).
  5. Minus up to 15 for recent 311 building complaints (2 pts each).
  6. Extra −10 if 3+ open heat-related violations.
  7. Chicago 311 takes no-heat complaints, but the City's public 311 dataset does not publish them as a separate type, so heat here comes from open Department of Buildings heat-related violations (codes/descriptions, e.g. CN132016 HEAT UNIT ADEQUATELY). 311 building complaints are counted separately, not as heat.
  8. Public records only — not an inspection, appraisal, or legal advice.

Sources: City of Chicago Building Violations (data.cityofchicago.org/d/22u3-xenr); City of Chicago 311 Service Requests (data.cityofchicago.org/d/v6vf-nfxy). Data: City of Chicago (chicago.gov). Data as of November 21, 2026 at 7:20 AM CT.

ScoutMyBuilding summarizes publicly available City data. It is informational only — not legal advice, not a housing inspection, and not a guarantee of current building conditions. City records may be incomplete, delayed, or inaccurate. Always verify with the City of Chicago Department of Buildings, 311, and your own walkthrough before signing a lease.

“This site provides applications using data that has been modified for use from its original source, www.cityofchicago.org, the official website of the City of Chicago. The City of Chicago makes no claims as to the content, accuracy, timeliness, or completeness of any of the data provided at this site. The data provided at this site is subject to change at any time. It is understood that the data provided at this site is being used at one’s own risk.” Required by the City of Chicago Data Terms of Use.

Check another address

Help: hello@scoutmybuilding.com