All open City violation records (14)
1 of 14 open City violation records are from the last 24 months (since November 2024), shown newest first. 13 older ones are collapsed below — still open, still counted.
- Open
CN190019 — ARRANGE PREMISE INSPECTION
ARRANGE FOR INSPECTION / UNABLE TO VERIFY INTERIOR CONDITIONS, DETECTORS OR CONCERNS REGARDING TO UNIT 2N BED BUG INFESTATION. PREVIOUS VIOLATIONS FROM 2023 REQUIRE WALK-THROUGH FOR VIOLATION REMOVAL.
Show 13 older open City violation records (before November 2024)
- Open
CN064014 — REPAIR CORNICE
WEST ELEVATION /CORNICE - WASHED OUT MORTAR JOINTS.
- Open
CN063014 — CHIMNEY
CHIMNEY - SPALLED BRICK SECTIONS WITH WASHED OUT MORTAR.
- Open
CN062024 — PARAPET
FRONT ELEVATION /PARAPET - MASONRY FRACTURES WITH OPEN MORTAR JOINTS.
- Open
CN061014 — REPAIR EXTERIOR WALL
FRONT AND WEST ELEVATIONS /EXTERIOR WALL - MASONRY DEFLECTIONS NEAR WINDOW LOCATIONS [MULTIPLE LOCATIONS].
- Open
CN190029 — ARRANGE FOR REINSPECTION REGAR
INTERIOR OF BUILDING - NO RESPONSE. UNVERIFIED DETECTORS AND CONDITIONS. UNABLE TO INSPECT INTERIOR STAIRWAY SYSTEMS. UNABLE TO CONFIRM INTERIOR COMPLAINT OF HOLE IN CEILING AT APT 2.
- Open
CN070014 — REPAIR EXTERIOR STAIR
NORTHEAST ELEVATION STAIR SYSTEM,4X4 COLUMNS REST ON CONCRETE SLAB,FOUNDATIONSTATUS UNKNOWN. STRINGER CONNECTIONS TO MASONARY WALLS NAILED ONLY. HAND RAILS MISSING AT MASONARY WALLS. PLANS AND PERMIT REQUIRED FOR REPLACEMENT.
- Open
CN190019 — ARRANGE PREMISE INSPECTION
INTERIOR OF BUILDING, NO RESPONSE TO MOST APARTMENTS IN ORDER TO VERIFY DETECTORS.
- Open
CN070014 — REPAIR EXTERIOR STAIR
REAR STAIRS AT NORTHEAST BREEZEWAY-MISSING HANDRAIL 2 REAR EXTERIOR STAIR SYSTEMS (CONDITIONS TYPICAL)-4X4 COLUMNS USED FOR SUPPORT OVER 12 FEET HIGH. 4X4 COLUMNS RESTING ON CONCRETE SLAB. FOUNDATION STATUS UNKNOWN. 4X4 COLUMNS WITH BOLT JOINTS, STRINGERS INADEQUATELY SUPPORTED. RAILINGS TOO LOW. STAIR TREADS WITH EXCESSIVE WEAR AND BROKEN. LOOSE DECKING, RAILINGS TOO LOW. PLANS AND PERMIT REQUIRED.
- Open
CN074014 — SERVICE WALK, PASSAGE, AREAWAY
EAST ELEVATION/SERVICE WALK-BUCKLED AND SUNKEN CONCRETE
- Open
CN070024 — REPAIR PORCH SYSTEM
REAR PORCH-6X6 COLUMNS RESTING ON CONCRETE SLAB-FOUNDATION STATUS UNKNOWN. LOOKOUT BEAMS MISSING TIE STRAPS. 1ST FLOOR LOOKOUT BEAMS BEARING ON 2X4'S THAT BEAR ON TOP OF WINDOW SILL. 2X8 JOIST OVER SPANNED (16+FEET). INADEQUATE BEAM COLUMN CONNECTION, STRINGERS INADEQUATELY SUPPORTED. STAIR TREADS TOO SMALL, RAILINGS TOO LOW. STAIRS ONLY 31 INCHES WIDE, PLANS AND PERMIT REQ.
- Open
CN131016 — SCREEN OUTER DOORS, WINDOWS
SCREEN DOOR BROKEN 1626 APT IS UNABLE TO LOCK THE DOOR
- Open
CN073014 — REPAIR EXTERIOR DOOR
BROKEN DOOR LOCK-REAR EXIT DOOR
- Open
EL0018 — DEFECTIVE OUTLETS
BROKEN WALL OUTLET 1626 APT IS IN THE KITCHEN
About these City violation records
From the City of Chicago Building Violations dataset description: “…informational only and does not necessarily reflect the current condition of the building or property. The dataset contains cases where a respondent has been found to be liable as well as cases where the respondent has been found to be not liable.”
311 complaints (24 months)
- rodent
Rodent Baiting/Rat Complaint
- building
Building Violation
Timeline
- 311 rodent — Rodent Baiting/Rat Complaint
- 311 building — Building Violation
- Open City violation record — CN190019 ARRANGE PREMISE INSPECTION
- Open City violation record — CN190029 ARRANGE FOR REINSPECTION REGAR
- Open City violation record — CN061014 REPAIR EXTERIOR WALL
- Open City violation record — CN062024 PARAPET
- Open City violation record — CN063014 CHIMNEY
- Open City violation record — CN064014 REPAIR CORNICE
- Open City violation record — CN190019 ARRANGE PREMISE INSPECTION
- Open City violation record — CN070014 REPAIR EXTERIOR STAIR
- Open City violation record — CN070024 REPAIR PORCH SYSTEM
- Open City violation record — CN074014 SERVICE WALK, PASSAGE, AREAWAY
- Open City violation record — CN070014 REPAIR EXTERIOR STAIR
- Open City violation record — EL0018 DEFECTIVE OUTLETS
- Open City violation record — CN073014 REPAIR EXTERIOR DOOR
- Open City violation record — CN131016 SCREEN OUTER DOORS, WINDOWS
Recently closed / other violations (sample)
- Closed / other
CN070024 REPAIR PORCH SYSTEM
- Closed / other
CN196029 POST OWNER/MANAGERS NAME/#
- Closed / other
CN198019 FILE BLDG REGISTRATION
- Closed / other
CN198019 FILE BLDG REGISTRATION
- Closed / other
CN131016 SCREEN OUTER DOORS, WINDOWS
- Closed / other
CN074014 SERVICE WALK, PASSAGE, AREAWAY
Around 1622 W Sherwin Ave
- Rogers Park building violations and 311 complaints
- Loyola Chicago off-campus housing: Rogers Park renter guide
Nearby buildings with open City violation records
Nearby addresses that also have open City violation records in the City of Chicago Building Violations dataset (22u3-xenr), by distance. Open each one for its current free report.
How the winter score is calculated
- Start at 100 (better = higher).
- Minus up to 40 for open heat/boiler-related building violations (12 pts each).
- Minus up to 45 for other open building violations (2 pts each, plus extras above 20 and 100 open).
- Minus up to 20 for rodent-related open violations and 311 rodent complaints (4 pts each).
- Minus up to 15 for recent 311 building complaints (2 pts each).
- Extra −10 if 3+ open heat-related violations.
- Chicago 311 takes no-heat complaints, but the City's public 311 dataset does not publish them as a separate type, so heat here comes from open Department of Buildings heat-related violations (codes/descriptions, e.g. CN132016 HEAT UNIT ADEQUATELY). 311 building complaints are counted separately, not as heat.
- Public records only — not an inspection, appraisal, or legal advice.
Sources: City of Chicago Building Violations (data.cityofchicago.org/d/22u3-xenr); City of Chicago 311 Service Requests (data.cityofchicago.org/d/v6vf-nfxy). Data: City of Chicago (chicago.gov). Data as of November 21, 2026 at 12:48 PM CT.
ScoutMyBuilding summarizes publicly available City data. It is informational only — not legal advice, not a housing inspection, and not a guarantee of current building conditions. City records may be incomplete, delayed, or inaccurate. Always verify with the City of Chicago Department of Buildings, 311, and your own walkthrough before signing a lease.
“This site provides applications using data that has been modified for use from its original source, www.cityofchicago.org, the official website of the City of Chicago. The City of Chicago makes no claims as to the content, accuracy, timeliness, or completeness of any of the data provided at this site. The data provided at this site is subject to change at any time. It is understood that the data provided at this site is being used at one’s own risk.” Required by the City of Chicago Data Terms of Use.