All open City violation records (35)
2 of 35 open City violation records are from the last 24 months (since November 2024), shown newest first. 33 older ones are collapsed below — still open, still counted.
- Open
CN190029 — ARRANGE FOR REINSPECTION REGAR
INTERIOR OF BUILDING - NO RESPONSE. UNVERIFIED DETECTORS AND CONDITIONS. UNABLE TO INSPECT INTERIOR STAIRWAY SYSTEMS. UNABLE TO CONFIRM INTERIOR COMPLAINT OF RODENT INFESTATION WITHIN APT 3A. (14A-1-104.7)
- Open
CN061014 — REPAIR EXTERIOR WALL
NORTH AND EAST ELEVATIONS /EXTERIOR WALL - SPALLED BRICK SECTIONS WITH MASONRY FRACTURES. (14X-3-303.6)
Show 33 older open City violation records (before November 2024)
- Open
CN190029 — ARRANGE FOR REINSPECTION REGAR
INTERIOR OF BUILDING - NO RESPONSE- UNVERIFIED DETECTORS AND CONDITIONS. REAR GATES LOCKED, NO ACCESS TO PORCH SYSTEMS. UNVERIFIED COMPLAINT OF UNIT 2B FROZEN PIPES.
- Open
CN065014 — REPAIR LINTELS
SOUTH ELEVATION, 3RD FLOOR LINTELS RUSTED.
- Open
CN065014 — REPAIR LINTELS
EAST ELEVATION 3RD FLOOR - RUSTED AND DEFLECTING LINTELS, MASONRY PERMIT REQUIRED FOR REPAIRS.
- Open
CN061014 — REPAIR EXTERIOR WALL
EAST ELEVATION OFF OF LINTELS - STEP FRACTURES AND WASHED OUT MORTAR.
- Open
CN063014 — CHIMNEY
EAST ELEVATION CHIMNEY - VERTICAL FRACTURE, WASHED OUT MORTAR, MISSING COPING TILES / CAPPING.
- Open
CN190019 — ARRANGE PREMISE INSPECTION
INTERIOR OF BUILDING, NO RESPONSE TO VERIFY DETECTORS.
- Open
CN198019 — FILE BLDG REGISTRATION
NO BUILDING REGISTRATION.
- Open
CN190019 — ARRANGE PREMISE INSPECTION
INTERIOR OF BUILDING, NO RESPONSE TO VERIFY DETECTORS.
- Open
CN196029 — POST OWNER/MANAGERS NAME/#
NO OWNER I.D POSTED.
- Open
CN190019 — ARRANGE PREMISE INSPECTION
AT 1616 UNIT 3A., NO ENTRY TO VERIFY COMPLAINT ABOUT BED BUG INFESTATION. (PROFESSIONAL EXTERMINATOR REQUIRED.).
- Open
CN106015 — REPAIR INTERIOR STAIR SYSTEM
AT 1616 STAIRS GRADE LO 1ST, TREADS ARE LOOSE.
- Heat-related
BR1042 — STEAM BOILER PERMIT
- Open
BR1001 — OWNER OR LICENSED CONTRACTOR
- Open
BR1072 — PROVIDE FRESH AIR
- Open
NC2053 — COMPLETE WORK
PORCH PERMIT #100231971 FAILED / PARTIAL ( 3 ) WOOD PORCHES AT WEST - WINDER STAIRS BUILT IMPROPPER, SINGLE STRINGERS NOT APPROVED, FIELD CHANGES TO JOIST TO 2 BY 12, REQUIRE PLAN CHANGES
- Open
CN063014 — CHIMNEY
SR#901336441 NORTHEAST CHIMNEY FRACTURED OPEN JOINTS AT TOP
- Open
EL0029 — EXPOSED WIRING
NORTH AND WEST LOOSE TANGLED CABLE LINES AND COVERS
- Open
NC6012 — 1HR PUB.CORRIDOR IN MULT. D.U.
NORTHWEST PORCH AREAWAY AT GRADE - FOAMBOARD CEILING NOT FIRERATED
- Open
CN063044 — CONNECT GAS APPLIANCE TO VENT
BOILER ROOM FLUE PIPE FOR WATER HEATER NO SEAL AT CHIMNEY BASE
- Open
PL157027 — REPLACE DEFECTIVE WASTE PIPING
BOILER ROOM AT NORTHWEST CORNER SEWER PIPE LEAKING AT FLOOR
- Open
CN197039 — RELOCATE SMOKE DETECTOR
ALL FRONT STAIR HALLS RELOCATE SMOKE DETECTORS FROM CENTER OF CEILINGS
- Open
CN031023 — FIRE EXTNGSHR RECHARGE & TAG
ALL FRONT STAIR HALLS - REMOVE EMPTY FIRE EXTINGUISHER CABINATES FROM ALL LANDINGS OR REATORE WITH TAGGED FIRE EXTINGUISHERS
- Open
CN104015 — REPLCE WINDOW PANES, PLEXGLAS
1616 FRONT HALL BROKEN WIRE GLASS AT IST FLOOR LANDING
- Open
CN113025 — BLOWER SYSTEM DIRECTLY OUTSIDE
BASEMENT LAUNDRY ROOM - COMMERCIAL DRYERS REQUIRE HARD PIPE VENT - PLASTIC UNITS COLLAPSED/ MELTED - FIRE/HAZARD
- Open
CN132046 — SAFE WORKING CONDITIONS
BASEMENT LAUNDRY ROOM - (2) COMMERCIAL DRYERS REQUIRE PILOT LIGHRT COVERS
- Open
CN076044 — REPAIR DOWNSPOUT
DOWNSPOUTS RUSTED AT NORTH AND WEST
- Open
CN104025 — MAINTAIN WINDOW SASH
PLYWOOD BASEMENT WINDOW PANELS LOOSE / DETERIORATED / FLAKING - NOT TO ORIGINAL LIGHT / VENTILATION PLAN
- Open
CN073024 — REPAIR EXTERIOR DOOR FRAME
WEST AREAWAY DOOR FRAME AT SOUTH ROTTED AT BASE
- Open
NC2053 — COMPLETE WORK
PORCH PERMIT #100231971 FAILED / PARTIAL ( 3 ) WOOD PORCHES AT WEST - WINDER STAIRS BUILT IMPROPPER, SINGLE STRINGERS NOT APPROVED, FIELD CHANGES TO JOIST TO 2 BY 12, REQUIRE PLAN CHANGES
- Open
CN061014 — REPAIR EXTERIOR WALL
NORTH AND WEST AT GRADE, SPALLED BRICKS WASHED OUT MORTAR
- Open
CN063014 — CHIMNEY
SR#901336441 NORTHEAST CHIMNEY FRACTURED OPEN JOINTS AT TOP
- Open
CN073024 — REPAIR EXTERIOR DOOR FRAME
WEST AREAWAY DOOR FRAME AT NORTH RUSTD AT BASE.
- Open
NC2053 — COMPLETE WORK
PORCH PERMIT #100231917 FAILED/PARTIAL (3) WOOD PORCHES AT WEST WINDER STAIRS BUILT IMPROPPER, SINGLE STRINGERS NOT APPROVED, FEILD CHANGES TO JOIST TO 2 BY 12'S REQUIRES PLAN CHANGES
About these City violation records
From the City of Chicago Building Violations dataset description: “…informational only and does not necessarily reflect the current condition of the building or property. The dataset contains cases where a respondent has been found to be liable as well as cases where the respondent has been found to be not liable.”
311 complaints (24 months)
No matching 311 complaints in the last 24 months.
Timeline
- Open City violation record — CN061014 REPAIR EXTERIOR WALL
- Open City violation record — CN190029 ARRANGE FOR REINSPECTION REGAR
- Open City violation record — CN065014 REPAIR LINTELS
- Open City violation record — CN190029 ARRANGE FOR REINSPECTION REGAR
- Open City violation record — CN063014 CHIMNEY
- Open City violation record — CN061014 REPAIR EXTERIOR WALL
- Open City violation record — CN065014 REPAIR LINTELS
- Open City violation record — CN196029 POST OWNER/MANAGERS NAME/#
- Open City violation record — CN190019 ARRANGE PREMISE INSPECTION
- Open City violation record — CN198019 FILE BLDG REGISTRATION
- Open City violation record — CN190019 ARRANGE PREMISE INSPECTION
- Open City violation record — CN106015 REPAIR INTERIOR STAIR SYSTEM
- Open City violation record — CN190019 ARRANGE PREMISE INSPECTION
- Open City violation record — BR1072 PROVIDE FRESH AIR
- Open City violation record — BR1001 OWNER OR LICENSED CONTRACTOR
- Open heat-related City violation record — BR1042 STEAM BOILER PERMIT
- Open City violation record — CN073024 REPAIR EXTERIOR DOOR FRAME
- Open City violation record — CN063014 CHIMNEY
- Open City violation record — CN061014 REPAIR EXTERIOR WALL
- Open City violation record — NC2053 COMPLETE WORK
- Open City violation record — CN073024 REPAIR EXTERIOR DOOR FRAME
- Open City violation record — CN104025 MAINTAIN WINDOW SASH
- Open City violation record — CN076044 REPAIR DOWNSPOUT
- Open City violation record — CN132046 SAFE WORKING CONDITIONS
- Open City violation record — CN113025 BLOWER SYSTEM DIRECTLY OUTSIDE
- Open City violation record — CN104015 REPLCE WINDOW PANES, PLEXGLAS
- Open City violation record — CN031023 FIRE EXTNGSHR RECHARGE & TAG
- Open City violation record — CN197039 RELOCATE SMOKE DETECTOR
- Open City violation record — PL157027 REPLACE DEFECTIVE WASTE PIPING
- Open City violation record — CN063044 CONNECT GAS APPLIANCE TO VENT
- Open City violation record — NC6012 1HR PUB.CORRIDOR IN MULT. D.U.
- Open City violation record — EL0029 EXPOSED WIRING
- Open City violation record — CN063014 CHIMNEY
- Open City violation record — NC2053 COMPLETE WORK
- Open City violation record — NC2053 COMPLETE WORK
Recently closed / other violations (sample)
- Closed / other
CN190020 INSPECT CONSTRUCTION WORK
- Closed / other
CN135016 MICE/RODENTS
- Closed / other
CN136016 ROACHES
- Closed / other
CN140046 PIGEONS-NESTING
- Closed / other
CN190019 ARRANGE PREMISE INSPECTION
- Closed / other
CN065014 REPAIR LINTELS
- Closed / other
CN061014 REPAIR EXTERIOR WALL
- Closed / other
CN063014 CHIMNEY
- Closed / other
CN196029 POST OWNER/MANAGERS NAME/#
- Closed / other
CN198019 FILE BLDG REGISTRATION
- Closed / other
CN106015 REPAIR INTERIOR STAIR SYSTEM
- Closed / other
CN190019 ARRANGE PREMISE INSPECTION
- Closed / other
CN061014 REPAIR EXTERIOR WALL
- Closed / other
NC6012 1HR PUB.CORRIDOR IN MULT. D.U.
- Closed / other
CN073024 REPAIR EXTERIOR DOOR FRAME
- Closed / other
NC2053 COMPLETE WORK
- Closed / other
CN063014 CHIMNEY
- Closed / other
EL0029 EXPOSED WIRING
- Closed / other
CN063044 CONNECT GAS APPLIANCE TO VENT
- Closed / other
PL157027 REPLACE DEFECTIVE WASTE PIPING
- Closed / other
CN197039 RELOCATE SMOKE DETECTOR
- Closed / other
CN031023 FIRE EXTNGSHR RECHARGE & TAG
- Closed / other
CN104015 REPLCE WINDOW PANES, PLEXGLAS
- Closed / other
CN113025 BLOWER SYSTEM DIRECTLY OUTSIDE
- Closed / other
CN132046 SAFE WORKING CONDITIONS
Around 1616 W Farwell Ave
- Rogers Park building violations and 311 complaints
- Loyola Chicago off-campus housing: Rogers Park renter guide
- No heat in your Chicago apartment? The heat ordinance and what to do
Nearby buildings with open City violation records
Nearby addresses that also have open City violation records in the City of Chicago Building Violations dataset (22u3-xenr), by distance. Open each one for its current free report.
How the winter score is calculated
- Start at 100 (better = higher).
- Minus up to 40 for open heat/boiler-related building violations (12 pts each).
- Minus up to 45 for other open building violations (2 pts each, plus extras above 20 and 100 open).
- Minus up to 20 for rodent-related open violations and 311 rodent complaints (4 pts each).
- Minus up to 15 for recent 311 building complaints (2 pts each).
- Extra −10 if 3+ open heat-related violations.
- Chicago 311 takes no-heat complaints, but the City's public 311 dataset does not publish them as a separate type, so heat here comes from open Department of Buildings heat-related violations (codes/descriptions, e.g. CN132016 HEAT UNIT ADEQUATELY). 311 building complaints are counted separately, not as heat.
- Public records only — not an inspection, appraisal, or legal advice.
Sources: City of Chicago Building Violations (data.cityofchicago.org/d/22u3-xenr); City of Chicago 311 Service Requests (data.cityofchicago.org/d/v6vf-nfxy). Data: City of Chicago (chicago.gov). Data as of November 21, 2026 at 12:42 PM CT.
ScoutMyBuilding summarizes publicly available City data. It is informational only — not legal advice, not a housing inspection, and not a guarantee of current building conditions. City records may be incomplete, delayed, or inaccurate. Always verify with the City of Chicago Department of Buildings, 311, and your own walkthrough before signing a lease.
“This site provides applications using data that has been modified for use from its original source, www.cityofchicago.org, the official website of the City of Chicago. The City of Chicago makes no claims as to the content, accuracy, timeliness, or completeness of any of the data provided at this site. The data provided at this site is subject to change at any time. It is understood that the data provided at this site is being used at one’s own risk.” Required by the City of Chicago Data Terms of Use.