Free building report
1548 W JUNEWAY TER
Winter habitability score Multiple habitability signals in public records
Renter reviews
Firsthand and anonymous. Renter opinions are separate from the city records below.
No renter reviews here yet. If you’ve lived at 1548 W Juneway Ter, yours could be the first.
Do you live here?
One tap helps other renters. The full building record stays right below.
Thanks for looking. The full record is right below.
No problem. The full record is right below.
Thanks, neighbor. Share how it’s really been — one tap on the stars is all it takes.
Thanks. Share how it really was — one tap on the stars is all it takes.
Sure, I’ll share
All open City violation records (21)
1 of 21 open City violation records are from the last 24 months (since November 2024), shown newest first. 20 older ones are collapsed below — still open, still counted.
- Open
CN190019 — ARRANGE PREMISE INSPECTION
INTERIOR OF BUILDING - NO RESPONSE. UNVERIFIED DETECTORS AND CONDITIONS. UNABLE TO INSPECT INTERIOR STAIRWAY SYSTEMS. (14A-1-104.7)
Show 20 older open City violation records (before November 2024)
- Open
CN190019 — ARRANGE PREMISE INSPECTION
NO ENTRY INTERIOR, UNABLE TO VERIFY DETECTORS, UNABLE TO INVESTIGATE COMPLAINT OF BROKEN LOCKS/ SECURITY DOORS.
- Open
CN062024 — PARAPET
SOUTH ELEVATION AND COURT YARD- VARIOUS LOCATIONS WITH FRACTURES AND OPEN MORTAR JOINTS.
- Open
CN061014 — REPAIR EXTERIOR WALL
REAR EXIT DOOR FRAME MISSING BRICK AND MORTAR AT LINTEL LEVEL.
- Open
CN133016 — CARPETING
1548 AND 1552 1/2 / INTERIOR STAIRS: TORN AND LOOSE CARPETS.
- Open
CN015012 — NO KEY TO USE EXIT DOOR
FENCE GATES WITH DOUBLE KEY LOCKS.
- Open
CN190029 — ARRANGE FOR REINSPECTION REGAR
ARRANGE FOR FINAL PORCH PERMIT INSPECTIONS ON THE FOLLOWING PERMITS: 100195258 ISSUED 08/17/07. AND 100267299 ISSUED 12/10/08
- Open
CN070024 — REPAIR PORCH SYSTEM
AT NORTH WEST CORNER-WOOD PORCH WITH 9 FOOT 6 INCH SPAND FOR 6X6 BEAM, CENTER COLUMN 4X4'S IS WRAPED AND RESTS ON FRACTURED PLINTH BLOCK. GUARD RAIL FROM 1ST THRU-3RD FL ARE UNDERSIZED NORTH EAST PORCH WITH 38 INCH HIGH GUARD RAILS, 9INCH DEEP THREADS. PLANS AND PERMITS REQUIRED
- Open
CN070024 — REPAIR PORCH SYSTEM
AT NORTH WEST CORNER-WOOD PORCH WITH 9 FOOT 6 INCH SPAN FOR 6"X6" BEAM. CENTER COLUMN 4"X4" IS WARPED AND RESTS ON A FRACTURED PLINTH BLOCK. GUARD RAILS FROM 1ST THRU 3RD FLOOR ARE UNDERSIZED NORTH EAST PORCH WITH 38 INCH HIGH GUARDRAILS; 9INCH DEEP TREAD. AT EAST ELEVATION- NORTH PORCH WITH 2"X8" JOISTS SPANNING 15 FEET. CENTER PORCH WITH 2"X8" JOISTS SPANNING 15 FEET; NO VISIBLE FOOTING. SOUTH PORCH LEDGER BEAMS ARE NOT BOLTED TO MASONRY WALL FIRST THRU SECOND FLOOR. NORTHEAST CORNER REAR PORCH: MIDDLE 4X4 COLUMN SPANING 3 FLR. SITTING ON CONCRETE SLAB WITH NO FOUNDATION BASE.PLANS AND PERMITS REQURED FOR REPAIRS.
- Open
CN104015 — REPLCE WINDOW PANES, PLEXGLAS
BROKEN PANE WEST ELEVATION FIRST FLOOR
- Open
CN070024 — REPAIR PORCH SYSTEM
AT NORTH WEST CORNER-WOOD PORCH WITH 9 FOOT 6 INCH SPAN FOR 6"X6" BEAM. CENTER COLUMN 4"X4" IS WARPED AND RESTS ON A FRACTURED PLINTH BLOCK. GUARD RAILS FROM 1ST THRU 3RD FLOOR ARE UNDERSIZED NORTH EAST PORCH WITH 38 INCH HIGH GUARDRAILS; 9INCH DEEP TREAD. AT EAST ELEVATION- NORTH PORCH WITH 2"X8" JOISTS SPANNING 15 FEET. CENTER PORCH WITH 2"X8" JOISTS SPANNING 15 FEET; NO VISIBLE FOOTING. SOUTH PORCH LEDGER BEAMS ARE NOT BOLTED TO MASONRY WALL FIRST THRU SECOND FLOOR. PLANS AND PERMITS NEEDED.
- Open
CN190019 — ARRANGE PREMISE INSPECTION
INTERIOR OF BUILDING- NO RESPONSE, UNVERIFIED DETECTORS, CONDITIONS, UNABLE TO INSPECT INTERIOR STAIRWAYS, REAR YARD-NO ENTRY-UNABLE TO REAR PORCHES, APT.1G-NO ENTRY UNABLE TO VERIFY COMPLAINT OF MICE INFESTATION.
- Open
CN198019 — FILE BLDG REGISTRATION
(SR#07-02058245)BUILDING NOT REGISTERED FOR 2007.
- Open
CN102015 — INT WALL/CEILING PEELING PAINT
LOOSE PAINT LIVING ROOM 3M CEILING BUCKLED.
- Open
CN197019 — INSTALL SMOKE DETECTORS
SMOKE DETECTOR MISSING AT STAIRWELL 1548.
- Open
CN197079 — REPAIR/REPLACE SMOKE DETECTORS
SMOKE DETECTOR NOT FUNCTIONING 3D APT. / APT. 3B RELOCATE NUISANCE ALARMS.
- Open
CN106015 — REPAIR INTERIOR STAIR SYSTEM
INTERIOR STAIRS AT M-N PICKETS MISSING AT 2ND AND 3RD. 1554 PICKETS MISSING.
- Open
CN140046 — PIGEONS-NESTING
PIGEON NUISANCE AT REAR PORCHES VARIOUS LOCATIONS.
- Open
CN131016 — SCREEN OUTER DOORS, WINDOWS
TORN SCREEN AT REAR DOOR VARIOUS LOCATIONS.
- Open
CN070024 — REPAIR PORCH SYSTEM
REAR PORCH: WEAK DECK BOARD (1X3'S), 2ND FLR. 1550. AT1552 & 1/2 RAIL HEIGHT IS 35" AT 1ST FLR., 37" AT 2ND FLR. HAND RAIL IS LOOSE AT GRADE TO 1ST. AT 1556/8 RAIL HEIGHT IS 36", ROOF ROTTING MEMBERS. OBTAIN PERMIT FOR REPAIRS.
- Open
CN107015 — ILLUMINATE PUBLIC STAIR/HALL
INSUFFICIENT LIGHT IN STAIRWELL AT 1548 1ST FLOOR.
About these City violation records
From the City of Chicago Building Violations dataset description: “…informational only and does not necessarily reflect the current condition of the building or property. The dataset contains cases where a respondent has been found to be liable as well as cases where the respondent has been found to be not liable.”
311 complaints (24 months)
- building
Building Violation
Timeline
- Open City violation record — CN190019 ARRANGE PREMISE INSPECTION
- 311 building — Building Violation
- Open City violation record — CN062024 PARAPET
- Open City violation record — CN190019 ARRANGE PREMISE INSPECTION
- Open City violation record — CN190029 ARRANGE FOR REINSPECTION REGAR
- Open City violation record — CN015012 NO KEY TO USE EXIT DOOR
- Open City violation record — CN133016 CARPETING
- Open City violation record — CN061014 REPAIR EXTERIOR WALL
- Open City violation record — CN070024 REPAIR PORCH SYSTEM
- Open City violation record — CN070024 REPAIR PORCH SYSTEM
- Open City violation record — CN104015 REPLCE WINDOW PANES, PLEXGLAS
- Open City violation record — CN070024 REPAIR PORCH SYSTEM
- Open City violation record — CN198019 FILE BLDG REGISTRATION
- Open City violation record — CN190019 ARRANGE PREMISE INSPECTION
- Open City violation record — CN107015 ILLUMINATE PUBLIC STAIR/HALL
- Open City violation record — CN070024 REPAIR PORCH SYSTEM
- Open City violation record — CN131016 SCREEN OUTER DOORS, WINDOWS
- Open City violation record — CN140046 PIGEONS-NESTING
- Open City violation record — CN106015 REPAIR INTERIOR STAIR SYSTEM
- Open City violation record — CN197079 REPAIR/REPLACE SMOKE DETECTORS
- Open City violation record — CN197019 INSTALL SMOKE DETECTORS
- Open City violation record — CN102015 INT WALL/CEILING PEELING PAINT
Recently closed / other violations (sample)
- Closed / other
CN190029 ARRANGE FOR REINSPECTION REGAR
- Closed / other
CN190019 ARRANGE PREMISE INSPECTION
- Closed / other
CN062024 PARAPET
- Closed / other
CN190029 ARRANGE FOR REINSPECTION REGAR
- Closed / other
CN133016 CARPETING
- Closed / other
CN061014 REPAIR EXTERIOR WALL
- Closed / other
CN015012 NO KEY TO USE EXIT DOOR
- Closed / other
CN131016 SCREEN OUTER DOORS, WINDOWS
- Closed / other
CN104015 REPLCE WINDOW PANES, PLEXGLAS
- Closed / other
CN065034 REPAIR WINDOW SILLS
- Closed / other
CN104015 REPLCE WINDOW PANES, PLEXGLAS
- Closed / other
CN061014 REPAIR EXTERIOR WALL
Around 1548 W Juneway Ter
- Rogers Park building violations and 311 complaints
- Loyola Chicago off-campus housing: Rogers Park renter guide
Nearby buildings with open City violation records
Nearby addresses that also have open City violation records in the City of Chicago Building Violations dataset (22u3-xenr), by distance. Open each one for its current free report.
How the winter score is calculated
- Start at 100 (better = higher).
- Minus up to 40 for open heat/boiler-related building violations (12 pts each).
- Minus up to 45 for other open building violations (2 pts each, plus extras above 20 and 100 open).
- Minus up to 20 for rodent-related open violations and 311 rodent complaints (4 pts each).
- Minus up to 15 for recent 311 building complaints (2 pts each).
- Extra −10 if 3+ open heat-related violations.
- Chicago 311 takes no-heat complaints, but the City's public 311 dataset does not publish them as a separate type, so heat here comes from open Department of Buildings heat-related violations (codes/descriptions, e.g. CN132016 HEAT UNIT ADEQUATELY). 311 building complaints are counted separately, not as heat.
- Public records only — not an inspection, appraisal, or legal advice.
Sources: City of Chicago Building Violations (data.cityofchicago.org/d/22u3-xenr); City of Chicago 311 Service Requests (data.cityofchicago.org/d/v6vf-nfxy). Data: City of Chicago (chicago.gov). Data as of November 21, 2026 at 8:41 AM CT.
ScoutMyBuilding summarizes publicly available City data. It is informational only — not legal advice, not a housing inspection, and not a guarantee of current building conditions. City records may be incomplete, delayed, or inaccurate. Always verify with the City of Chicago Department of Buildings, 311, and your own walkthrough before signing a lease.
“This site provides applications using data that has been modified for use from its original source, www.cityofchicago.org, the official website of the City of Chicago. The City of Chicago makes no claims as to the content, accuracy, timeliness, or completeness of any of the data provided at this site. The data provided at this site is subject to change at any time. It is understood that the data provided at this site is being used at one’s own risk.” Required by the City of Chicago Data Terms of Use.