Free building report

1527 W Superior St

Winter habitability score Multiple habitability signals in public records

Download a PDF of this report

Renter reviews

Firsthand and anonymous. Renter opinions are separate from the city records below.

No renter reviews here yet. If you’ve lived at 1527 W Superior St, yours could be the first.

A Chicago three-flat

Do you live here?

One tap helps other renters. The full building record stays right below.

Sure, I’ll share
How’s it been living here? Required

Tap a star — 1 is rough, 5 is great.

Add more detail (optional — heat, pests, repairs, noise, management)

Tap 1 to 5 for any you want. 1 is rough, 5 is great. Skip the rest.

Heat Warm enough when it counts?
Pests Have pests been a problem?
Maintenance responsiveness When something broke, how fast did it get fixed?
Noise How noisy was it, day to day?
Management How they treated you and answered you
Would you rent here again?

Your own experience only — no fake or paid reviews. Shown anonymously after you confirm and a person approves it. Review policy · Terms

48Open City violation records
0Open heat-related City records
0311 rodent (24 mo)
0311 building (24 mo)

What rat complaints mean →

All open City violation records (48)

No open City violation records dated in the last 24 months (since November 2024). The newest open one is from September 1, 2017. All 48 are collapsed below — still open, still counted.

Show 48 older open City violation records (before November 2024)
  • Open

    CN061014 — REPAIR EXTERIOR WALL

    REAR ELEVATION / ENCLOSED REAR PORCH / MULTIPLE SECTIONS OF SIDING - MISSING.

  • Open

    CN070014 — REPAIR EXTERIOR STAIR

    FRONT 1-STORY EXTERIOR MASONRY STAIRWAY - SEVERELY CRACKED AND SPALLING CONCRETE. PERMIT ONLY REQUIRED FOR REPAIRS OF FRONT EXTERIOR STAIRWAY.

  • Open

    CN190019 — ARRANGE PREMISE INSPECTION

    INTERIOR OF THE BUILDING - NO RESPONSE, UNVERIFIED DETECTORS AND CONDITIONS. REAR YARD - LOCKED GATES, UNABLE TO INSPECT ENCLOSED REAR PORCH.

  • Open

    PL151137 — OPEN

  • Open

    ELX0001 — EXAMINER'S COMMENTS:

    NEED MOGUL TYPE LB`S 18-27-370.16

  • Open

    ELX023 — INSTALL COVERS

  • Open

    ELSW02 — WORKMANLIKE MANNER

  • Open

    EL0084 — SEE INSPECTOR COMMENTS

    SEE DEFECT NOTICE

  • Open

    CN067024 — REPAIR EAVES

    EAVES AND FASCIA - SOUTH, WEST, NORTH AND EAST ELEVATION ROTTED, PEELING PAINT AND HOLES.

  • Open

    CN076024 — REPAIR GUTTER & DOWNSPOUT

    DOWNSPOUT AND GUTTERS - EAST AND WEST ELEVATION GUTTERS AND DOWNSPOUTS RUSTED. GUTTERS DAMAGED AND LOOSE.

  • Open

    CN074014 — SERVICE WALK, PASSAGE, AREAWAY

    REAR SERVICE WALK - BROKEN AND UNEVEN CONCRETE.

  • Open

    CN104035 — MAINTAIN WINDOW

    WINDOW FRAMES ROTTED WEST AND EAST ELEVATION, 1ST AND 2ND FLOOR.

  • Open

    CN104035 — MAINTAIN WINDOW

    WINDOW SILLS ROTTED WEST AND EAST ELEVATION, 1ST AND 2ND FLOOR.

  • Open

    CN138106 — STOP/REMOVE NUISANCE

    REAR YARD - 2 ABANDONED CARS, PLATES MISSING.

  • Open

    NC2021 — PERMIT REQUIRED - CONTRACTOR

    PERIMETER FENCE IN EXCESS OF 5 FT. IN HEIGHT, REDUCE OR OBTAIN PERMIT.

  • Open

    CN070024 — REPAIR PORCH SYSTEM

    REAR PORCH - HANDRAIL, LADDER DESIGN EAST HANDRAIL MISSING, RISERS VARYING IN HEIGHT, 1ST FLOOR LANDING PLYWOOD BUCKLING, COLUMN ROTTED, 1ST FLOOR GUARDRAIL SYSTEM HEIGHT LESS THAN 42 INCHES, PICKETS EXCESSIVE SPACING, LEDGER NO VISIBLE FASTENER AT EXTERIOR WALL.

  • Open

    CN073044 — REPAIR EXTERIOR DOOR HARDWARE

    EXTERIOR DOOR HARDWARE - ENTRY DOOR KNOB LOOSE.

  • Open

    CN197019 — INSTALL SMOKE DETECTORS

    SMOKE DETECTORS MISSING - 2ND FLOOR INTERIOR STAIRWAY, BASEMENT SLEEPING AREA, 1ST FLOOR APARTMENT.

  • Open

    CN197087 — CARB MONOX DETECT IN RESID

    CARBON MONOXIDE DETECTORS MISSING - 1ST FLOOR APARTMENT AND BASEMENT.

  • Open

    NC1010 — CONTRARY TO ORIGINAL PLAN

    BASEMENT ORIGINALLY STORAGE NOW BEING USED AS SLEEPING AREA.

  • Open

    NC2011 — PLANS & PERMITS REQ - CONTRCTR

    SUBMIT PLANS AND PERMIT FOR ALTERATIONS IN BASEMENT. WALLS FORMED TO ACCOMMODATE SLEEPING AREA AND BATHROOM.

  • Open

    NC2071 — WORK NOT ALLOWED

    REMOVE ALL NON-LOAD BEARING WALLS ERECTED WITHOUT PERMIT IN BASEMENT.

  • Open

    CN140016 — DWELLING CLEAN AND SANITARY

    UNSANITARY CONDITIONS, BASEMENT FILTHY.

  • Open

    PL234018 — INSTALL VENT PIPE FOR TRAP

    FIRST FLOOR KITCHEN SINK WASTE IS "S" TRAPPED. PROVIDE VENT FOR SINK TRAP.

  • Open

    PL237020 — PROPER MATRL WATER SUPPLY PIPE

    PLASTIC WATER SUPPLIES TO ALL THE PLUMBING FIXTURES.

  • Open

    PL232040 — RMV PLBFIX INSTALLD W/0 PERMIT

    BASEMENT - REMOVE ALL THE PLUMBING FOR POWDER ROOM.

  • Open

    PL239010 — ENGAG LIC & BOND PLMBNG CNTRC

    HIRE A LICENSED PLUMBING CONTRACTOR.

  • Open

    EL0016 — ADD RECEPTACLES

    ADD RECEPTACLES TO EASE EXTENSION CORD USE THROUGHOUT 1ST FLOOR AREA AND BASEMENT AREAS - AND OTHER TYPICAL UNITS THROUGHOUT BUILDING.

  • Open

    EL0017 — CONTINUITY OF RACEWAY

    PROVIDE GROUND CONTINUITY FOR ARMORED CABLE APART AT FITTINGS THROUGHOUT BASEMENT AREAS - DANGEROUS AND HAZARDOUS CONDITION.

  • Open

    EL0019 — DEFECTIVE FIXTURES

    REPLACE ALL DEFECTIVE LIGHTS THROUGHOUT 1ST FLOOR AND BASEMENT AREAS AND OTHER TYPICAL UNITS THROUGHOUT THE BUILDING.

  • Open

    EL0023 — INSTALL COVERS

    PROVIDE PROPER TYPE COVERS FOR OPEN JUNCTION WITH EXPOSED WIRING AND PANELS OPEN WITH EXPOSED LIVE PARTS THROUGHOUT BASEMENT AREAS - DANGEROUS AND HAZARDOUS CONDITION.

  • Open

    EL0030 — ARMORED CABLE

    REPLACE ALL EXCESSIVE USE AND DEFECTIVE ARMORED CABLE THROUGHOUT ALL BASEMENT AREAS - DANGEROUS AND HAZARDOUS CONDITION.

  • Open

    EL0084 — SEE INSPECTOR COMMENTS

    PROVIDE WEATHERPROOF BOXES, LIGHTS, FITTINGS AND APPROVED RACEWAY FOR REAR PORCH AREAS. (18-27-110.11)

  • Open

    EL0085 — Violation

    REPLACE ALL DEFECTIVE AND DETERIORATED WIRING THROUGHOUT BASEMENT, 1ST FLOOR AREAS. (18-27-110.7)

  • Open

    EL0001 — DEFECTIVE LIGHTING SERVICE

    REPLACE DEFECTIVE SERVICE ENTRANCE CABLE RISER.

  • Open

    EL0042 — GROUND EQUIPMENT

    PROVIDE A WATER MAIN GROUND CONDUCTOR TO WITHIN 5 FT. OF WATER METER OR VALVE.

  • Open

    PL171017 — OBTN PERMIT FOR PLUMBING WORK

    PULL A PLUMBING PERMIT.

  • Open

    EL0086 — Violation

    PROVIDE PUBLIC METER AND PANEL FOR SEPARATE LIVING SPACE, COMMON AREAS, BASEMENT AREAS AND GARAGE. (18-27-210.25)

  • Open

    EL0086 — Violation

    OBTAIN ELECTRICAL PERMIT AND CONTRACTOR TO CORRECT VIOLATIONS. (13-12-360)

  • Open

    CN196029 — POST OWNER/MANAGERS NAME/#

    POST OWNERSHIP.

  • Open

    CN015012 — NO KEY TO USE EXIT DOOR

    GATE DOUBLE KEY LOCK.

  • Open

    CN070014 — REPAIR EXTERIOR STAIR

    EXTERIOR STAIR SYSTEM: GRADE TO BASEMENT STAIR SYSTEM - GUARDRAIL AND HANDRAIL MISSING AT NORTH ELEVATION. NORTH ELEVATION GRADE TO 1ST FLOOR - HANDRAILS LESS THAN 32 INCHES IN HEIGHT. CARPET COVERING TREADS AND RISER TORN, TRIPPING HAZARD. NORTHEAST SIDE WALLS CRUMBLING CONCRETE. TREADS AND RISERS VARYING IN HEIGHT AND CRUMBLING CONCRETE NORTHEAST AND CRUMBLING CONCRETE. ROOF OVER EXTERIOR STAIRS - SHINGLES DETERIORATING WITH GREEN MOSS GROWING NORTHEAST. DECK BOARDS - WORN, ALL WOOD COMPONENTS PEELING PAINT. REAR EXTERIOR STAIR SYSTEM - HANDRAIL MISSING. CINDER BLOCK GUARDRAIL SYSTEM - WASHED OUT MORTAR AND MISSING BRICKS. CONCRETE TREADS CRACKED. REPAIR, NO PERMIT REQUIRED.

  • Open

    CN063014 — CHIMNEY

    CHIMNEY WASHED OUT MORTAR.

  • Open

    CN061014 — REPAIR EXTERIOR WALL

    EXTERIOR WALL REPAIR SOUTH AND EAST ELEVATION - 1ST FLOOR EXPOSED WOOD SHEATHING LOOSE, ROTTED DETERIORATING SIDING, HOLES, BULGING AND MISSING SECTIONS.

  • Open

    CN063024 — CHIMNEY CAPPING

    CHIMNEY - MISSING CAPPING.

  • Open

    CN190019 — ARRANGE PREMISE INSPECTION

    INTERIOR OF BUILDING: NO RESPONSE - UNVERIFIED DETECTORS, OCCUPANCY AND CONDITIONS. UNABLE TO INSPECT FRONT AND REAR PORCHES - TWO LOOSE BROWN AND BLACK PITBULLS DOGS SITTING ON FRONT PORCH.

  • Open

    NC2021 — PERMIT REQUIRED - CONTRACTOR

    6 FT. HIGH WROUGHT IRON FENCE AND GATE INSTALLED WITHOUT A PERMIT.

  • Open

    CN196029 — POST OWNER/MANAGERS NAME/#

    BLDG. - OWNER'S I.D SIGN - MISSING

About these City violation records

From the City of Chicago Building Violations dataset description: “…informational only and does not necessarily reflect the current condition of the building or property. The dataset contains cases where a respondent has been found to be liable as well as cases where the respondent has been found to be not liable.”

↑ Back to renter reviews

311 complaints (24 months)

No matching 311 complaints in the last 24 months.

Timeline

  1. Open City violation record — CN190019 ARRANGE PREMISE INSPECTION
  2. Open City violation record — CN070014 REPAIR EXTERIOR STAIR
  3. Open City violation record — CN061014 REPAIR EXTERIOR WALL
  4. Open City violation record — PL151137 OPEN
  5. Open City violation record — ELSW02 WORKMANLIKE MANNER
  6. Open City violation record — ELX023 INSTALL COVERS
  7. Open City violation record — ELX0001 EXAMINER'S COMMENTS:
  8. Open City violation record — EL0084 SEE INSPECTOR COMMENTS
  9. Open City violation record — CN061014 REPAIR EXTERIOR WALL
  10. Open City violation record — CN063014 CHIMNEY
  11. Open City violation record — CN070014 REPAIR EXTERIOR STAIR
  12. Open City violation record — CN015012 NO KEY TO USE EXIT DOOR
  13. Open City violation record — CN196029 POST OWNER/MANAGERS NAME/#
  14. Open City violation record — EL0086
  15. Open City violation record — EL0086
  16. Open City violation record — PL171017 OBTN PERMIT FOR PLUMBING WORK
  17. Open City violation record — EL0042 GROUND EQUIPMENT
  18. Open City violation record — EL0001 DEFECTIVE LIGHTING SERVICE
  19. Open City violation record — EL0085
  20. Open City violation record — EL0084 SEE INSPECTOR COMMENTS
  21. Open City violation record — EL0030 ARMORED CABLE
  22. Open City violation record — EL0023 INSTALL COVERS
  23. Open City violation record — EL0019 DEFECTIVE FIXTURES
  24. Open City violation record — EL0017 CONTINUITY OF RACEWAY
  25. Open City violation record — EL0016 ADD RECEPTACLES
  26. Open City violation record — PL239010 ENGAG LIC & BOND PLMBNG CNTRC
  27. Open City violation record — PL232040 RMV PLBFIX INSTALLD W/0 PERMIT
  28. Open City violation record — PL237020 PROPER MATRL WATER SUPPLY PIPE
  29. Open City violation record — PL234018 INSTALL VENT PIPE FOR TRAP
  30. Open City violation record — CN140016 DWELLING CLEAN AND SANITARY
  31. Open City violation record — NC2071 WORK NOT ALLOWED
  32. Open City violation record — NC2011 PLANS & PERMITS REQ - CONTRCTR
  33. Open City violation record — NC1010 CONTRARY TO ORIGINAL PLAN
  34. Open City violation record — CN197087 CARB MONOX DETECT IN RESID
  35. Open City violation record — CN197019 INSTALL SMOKE DETECTORS
  36. Open City violation record — CN073044 REPAIR EXTERIOR DOOR HARDWARE
  37. Open City violation record — CN070024 REPAIR PORCH SYSTEM
  38. Open City violation record — NC2021 PERMIT REQUIRED - CONTRACTOR
  39. Open City violation record — CN138106 STOP/REMOVE NUISANCE
  40. Open City violation record — CN104035 MAINTAIN WINDOW

Recently closed / other violations (sample)

No recent closed violations in the sample.

Around 1527 W Superior St

Nearby buildings with open City violation records

Nearby addresses that also have open City violation records in the City of Chicago Building Violations dataset (22u3-xenr), by distance. Open each one for its current free report.

How the winter score is calculated
  1. Start at 100 (better = higher).
  2. Minus up to 40 for open heat/boiler-related building violations (12 pts each).
  3. Minus up to 45 for other open building violations (2 pts each, plus extras above 20 and 100 open).
  4. Minus up to 20 for rodent-related open violations and 311 rodent complaints (4 pts each).
  5. Minus up to 15 for recent 311 building complaints (2 pts each).
  6. Extra −10 if 3+ open heat-related violations.
  7. Chicago 311 takes no-heat complaints, but the City's public 311 dataset does not publish them as a separate type, so heat here comes from open Department of Buildings heat-related violations (codes/descriptions, e.g. CN132016 HEAT UNIT ADEQUATELY). 311 building complaints are counted separately, not as heat.
  8. Public records only — not an inspection, appraisal, or legal advice.

Sources: City of Chicago Building Violations (data.cityofchicago.org/d/22u3-xenr); City of Chicago 311 Service Requests (data.cityofchicago.org/d/v6vf-nfxy). Data: City of Chicago (chicago.gov). Data as of November 21, 2026 at 4:04 PM CT.

ScoutMyBuilding summarizes publicly available City data. It is informational only — not legal advice, not a housing inspection, and not a guarantee of current building conditions. City records may be incomplete, delayed, or inaccurate. Always verify with the City of Chicago Department of Buildings, 311, and your own walkthrough before signing a lease.

“This site provides applications using data that has been modified for use from its original source, www.cityofchicago.org, the official website of the City of Chicago. The City of Chicago makes no claims as to the content, accuracy, timeliness, or completeness of any of the data provided at this site. The data provided at this site is subject to change at any time. It is understood that the data provided at this site is being used at one’s own risk.” Required by the City of Chicago Data Terms of Use.

Check another address

Help: hello@scoutmybuilding.com