Free building report
1516 W Farwell Ave
Winter habitability score Open City violation records are on file — read the list, not just the score
Renter reviews
Firsthand and anonymous. Renter opinions are separate from the city records below.
No renter reviews here yet. If you’ve lived at 1516 W Farwell Ave, yours could be the first.
Do you live here?
One tap helps other renters. The full building record stays right below.
Thanks for looking. The full record is right below.
No problem. The full record is right below.
Thanks, neighbor. Share how it’s really been — one tap on the stars is all it takes.
Thanks. Share how it really was — one tap on the stars is all it takes.
Sure, I’ll share
All open City violation records (8)
No open City violation records dated in the last 24 months (since November 2024). The newest open one is from February 8, 2019. All 8 are collapsed below — still open, still counted.
Show 8 older open City violation records (before November 2024)
- Open
CN190019 — ARRANGE PREMISE INSPECTION
INTERIOR OF BUILDING /REFUSED ENTRY. UNABLE TO VERIFY DETECTORS AND CONDITIONS. UNVERIFIED COMPLAINT OF CEILING LEAKING UNIT 1.
- Open
CN196029 — POST OWNER/MANAGERS NAME/#
BUILDING /NO OWNER'S ID SIGN POSTED.
- Open
NC2021 — PERMIT REQUIRED - CONTRACTOR
REPLACING DRYWALL IN BASEMENT
- Open
NC2022 — BLANK-TEXT MUST CITE CODE SECT
STOP ALL WORK UNTIL PERMIT IS OBTAINEDSECTION 13.12.080, 13.32.035
- Open
CN190019 — ARRANGE PREMISE INSPECTION
INTERIOR OF THE BUILDING - NO RESPONSE, UNVERIFIED DETECTORS AND CONDITIONS.
- Open
CN066034 — REPAIR BALCONY
SOUTH ELEVATION / 2ND FLOOR BALCONY - ROTTING DECK JOISTS. GUARD RAILING SECTIONS - ROTTING, FASTENED TO POSTS AND EXTERIOR WALLS WITH NAILS ONLY. DECK BOARDS - ROTTING, BUCKLED UP. PLANS AND PERMIT REQUIRED FOR BALCONY REPLACEMENT.
- Open
CN070034 — REPLACE D&H PORCH
NORTH ELEVATION / 2-STORY WOOD PORCH - ALL COLUMNS ERECTED ON CONCRETE SLAB, FOUNDATION STATUS UNKNOWN. COLUMNS - OUT OF PLUMB, BOWING AND TWISTING; HAVE INADEQUATE HALF-LAP JOINTS WITH ONLY TWO BOLTS, PULLING APART AND SEPARATING. LEDGER BEAMS FASTENED TO BUILDING EXTERIOR WALLS WITH NAILS ONLY. BEAMS PULLING OUT OF FIRE CUTS. DECK JOISTS FASTENED TO LEDGER BEAMS WITH TOE NAILS ONLY. UPPER AND LOWER ENDS OF STRINGERS INADEQUATELY SUPPORTED AT HEADER JOISTS AND COLUMNS WITH NAILS ONLY. ALL RAILING SECTIONS - LOOSE, WEAK, PULLING; ATTACHED TO COLUMNS AND BUILDING'S WALLS WITH NAILS ONLY. TREADS - WORN OUT, CRACKED AND WEAK. ENTIRE PORCH STRUCTURE - WEAK. PLANS AND PERMIT REQUIRED FOR PORCH REPLACEMENT.
- Open
CN070014 — REPAIR EXTERIOR STAIR
FRONT CONCRETE STAIRS / RETAINING WALLS - BULGING, SHIFTING MASONRY. PERMIT ONLY REQUIRED FOR MASONRY REPAIRS.
About these City violation records
From the City of Chicago Building Violations dataset description: “…informational only and does not necessarily reflect the current condition of the building or property. The dataset contains cases where a respondent has been found to be liable as well as cases where the respondent has been found to be not liable.”
311 complaints (24 months)
No matching 311 complaints in the last 24 months.
Timeline
- Open City violation record — CN196029 POST OWNER/MANAGERS NAME/#
- Open City violation record — CN190019 ARRANGE PREMISE INSPECTION
- Open City violation record — NC2022 BLANK-TEXT MUST CITE CODE SECT
- Open City violation record — NC2021 PERMIT REQUIRED - CONTRACTOR
- Open City violation record — CN070014 REPAIR EXTERIOR STAIR
- Open City violation record — CN070034 REPLACE D&H PORCH
- Open City violation record — CN066034 REPAIR BALCONY
- Open City violation record — CN190019 ARRANGE PREMISE INSPECTION
Recently closed / other violations (sample)
No recent closed violations in the sample.
Around 1516 W Farwell Ave
- Rogers Park building violations and 311 complaints
- Loyola Chicago off-campus housing: Rogers Park renter guide
Nearby buildings with open City violation records
Nearby addresses that also have open City violation records in the City of Chicago Building Violations dataset (22u3-xenr), by distance. Open each one for its current free report.
How the winter score is calculated
- Start at 100 (better = higher).
- Minus up to 40 for open heat/boiler-related building violations (12 pts each).
- Minus up to 45 for other open building violations (2 pts each, plus extras above 20 and 100 open).
- Minus up to 20 for rodent-related open violations and 311 rodent complaints (4 pts each).
- Minus up to 15 for recent 311 building complaints (2 pts each).
- Extra −10 if 3+ open heat-related violations.
- Chicago 311 takes no-heat complaints, but the City's public 311 dataset does not publish them as a separate type, so heat here comes from open Department of Buildings heat-related violations (codes/descriptions, e.g. CN132016 HEAT UNIT ADEQUATELY). 311 building complaints are counted separately, not as heat.
- Public records only — not an inspection, appraisal, or legal advice.
Sources: City of Chicago Building Violations (data.cityofchicago.org/d/22u3-xenr); City of Chicago 311 Service Requests (data.cityofchicago.org/d/v6vf-nfxy). Data: City of Chicago (chicago.gov). Data as of November 21, 2026 at 10:23 AM CT.
ScoutMyBuilding summarizes publicly available City data. It is informational only — not legal advice, not a housing inspection, and not a guarantee of current building conditions. City records may be incomplete, delayed, or inaccurate. Always verify with the City of Chicago Department of Buildings, 311, and your own walkthrough before signing a lease.
“This site provides applications using data that has been modified for use from its original source, www.cityofchicago.org, the official website of the City of Chicago. The City of Chicago makes no claims as to the content, accuracy, timeliness, or completeness of any of the data provided at this site. The data provided at this site is subject to change at any time. It is understood that the data provided at this site is being used at one’s own risk.” Required by the City of Chicago Data Terms of Use.