1502 W POLK ST
Winter habitability score Some issues on record — read the details
Renter reviews
Firsthand and anonymous. Renter opinions are separate from the city records below.
No renter reviews here yet. If you’ve lived at 1502 W Polk St, yours could be the first.
Do you live here?
One tap helps other renters. The full building record stays right below.
Thanks for looking. The full record is right below.
No problem. The full record is right below.
Thanks, neighbor. Share how it’s really been — one tap on the stars is all it takes.
Thanks. Share how it really was — one tap on the stars is all it takes.
Sure, I’ll share
All open City violation records (12)
No open City violation records dated in the last 24 months (since November 2024). The newest open one is from January 22, 2022. All 12 are collapsed below — still open, still counted.
Show 12 older open City violation records (before November 2024)
- Open
CN104075 — WINDOW REPAIR FOR AIR SEEPAGE
1502 W. / 2ND FLOOR / REAR BEDROOM - OUTSIDE AIR SEEPING IN THROUGH CRACKS/GAPS AROUND THE WINDOW. (14X-3-303.13 AND 14X-12-1202.4.3.3)
- Open
CN197019 — INSTALL SMOKE DETECTORS
1502 W / 2ND FLOOR / SMOKE DETECTOR MISSING - FRONT BEDROOM & HALL WAY. (14X-5-504.8, 14X-5-504.8.4, 14B-9-907.2.10.1 THROUGH 14B-9-907.2.10.7, AND 14R-11-1104)
- Open
CN070034 — REPLACE D&H PORCH
REAR 3-STORY WOOD PORCH: 6X6 COLUMNS RESTING ON CONCRETE SLAB, FOUNDATION STATUS UNKNOWN. UNDERSIZED 2X8 JOIST SPAN 13'. RAIL SYSTEM LOOSE AND PULLING. GUARD RAILS ONLY 37" HIGH. HAND RAILS ONLY 32" HIGH. RIGHT SIDE HAND RAIL FROM 1ST TO 3RD MISSING PICKETS. 4X4 COLUMNS OVER NOTCHED. UNDERSIZED 2X6 ROOF JOISTS SPAN 12'. STRINGERS NOT ADEQUATELY SUPPORTED. ROOF JOIST, TREADS, AND RISERS CRACKED AND ROTTED. STAIRS FROM 1ST TO 3RD FLOOR STARTING TO SWAY. PORCH ONLY NAILED.PLANS AND PERMIT REQUIRED TO REPLACE REAR 3-STORY WOOD PORCH.
- Open
CN190029 — ARRANGE FOR REINSPECTION REGAR
INTERIOR OF BUILDING - NO RESPONSE, UNVERIFIED DETECTORS, CONDITIONS, OCCUPANCY AND BUILDING DATA.
- Open
CN062034 — REPAIR COPING
FRONT ELEVATION / COPING STONES - WASHED OUT MORTAR.
- Open
CN061014 — REPAIR EXTERIOR WALL
FRONT ELEVATION / SOUTH-EAST CORNER / ABOVE 3RD FLOOR WINDOW / SECTION OF STONEWORK - CRACKED AND SHIFTING. PERMIT ONLY REQUIRED FOR MASONRY REPAIRS.FRONT ELEVATION / BAY WINDOWS / ABOVE 3RD FLOOR WINDOWS / STONEWORK - WASHED OUT MORTAR. PERMIT ONLY REQUIRED FOR MASONRY REPAIRS.FRONT ELEVATION / EXTERIOR WALL / GRADE TO 3RD FLOOR / MULTIPLE LOCATIONS - WASHED OUT MORTAR. PERMIT ONLY REQUIRED FOR MASONRY REPAIRS.
- Open
CN070024 — REPAIR PORCH SYSTEM
REAR 3-STORY WOOD PORCH - ALL COLUMNS ERECTED ON CONCRETE SLAB, FOUNDATION STATUS UNKNOWN; 4X4 COLUMNS STACKED UP ON TOP OF 4X4 COLUMNS AND FASTENED WITH NAILS ONLY; ONE COLUMNS - SITS ON EDGE OF CATCH BASIN. BEAMS PULLING OUT OF FIRE CUTS. ALL DECKING - WEAK; LARGE SECTIONS CUT OUT. 1ST FLOOR JOINSTS - TOE NAILED ONLY. UPPER AND LOWER ENDS OF STRINGERS INADEQUATELY SUPPORTED AT HEADER JOISTS AND AT COLUMNS WITH NAILS ONLY; PULLING AWAY FROM HEADER JOINTS. ALL RAILING SECTIONS - LOOSE, WEAK, PULLING; ATTACHED TO COLUMNS WITH NAILS ONLY. TREADS - WORN OUT, CRACKED AND WEAK. PLANS AND PERMIT REQUIRED FOR REAR PORCH REPAIRS.
- Open
CN065034 — REPAIR WINDOW SILLS
FRONT ELEVATION / 1ST TO 3RD FLOORS / WINDOW SILLS - WASHED OUT MORTAR. PERMIT ONLY REQUIRED FOR MASONRY REPAIRS.
- Open
CN190019 — ARRANGE PREMISE INSPECTION
INTERIOR OF THE BUILDING - NO RESPONSE, UNVERIFIED DETECTORS AND CONDITIONS.
- Open
CN196029 — POST OWNER/MANAGERS NAME/#
BUILDING MANAGEMENT'S ID SIGN - NOT POSTED.
- Open
CN070014 — REPAIR EXTERIOR STAIR
FRONT ELEVATION / GRADE TO BASEMENT / EXTERIOR STAIRWAY / HANDRAILS - MISSING.
- Open
NC2071 — WORK NOT ALLOWED
EXCAVATED FRONT YARD AND ERECTED 10' BY 10' FOUNDATION UP TO PUBLIC WALKNOT ALLOWED PER ZONING ORDINANCE 17-2-0305
About these City violation records
From the City of Chicago Building Violations dataset description: “…informational only and does not necessarily reflect the current condition of the building or property. The dataset contains cases where a respondent has been found to be liable as well as cases where the respondent has been found to be not liable.”
311 complaints (24 months)
No matching 311 complaints in the last 24 months.
Timeline
- Open City violation record — CN197019 INSTALL SMOKE DETECTORS
- Open City violation record — CN104075 WINDOW REPAIR FOR AIR SEEPAGE
- Open City violation record — CN190029 ARRANGE FOR REINSPECTION REGAR
- Open City violation record — CN070034 REPLACE D&H PORCH
- Open City violation record — CN070014 REPAIR EXTERIOR STAIR
- Open City violation record — CN196029 POST OWNER/MANAGERS NAME/#
- Open City violation record — CN190019 ARRANGE PREMISE INSPECTION
- Open City violation record — CN065034 REPAIR WINDOW SILLS
- Open City violation record — CN070024 REPAIR PORCH SYSTEM
- Open City violation record — CN061014 REPAIR EXTERIOR WALL
- Open City violation record — CN062034 REPAIR COPING
- Open City violation record — NC2071 WORK NOT ALLOWED
Recently closed / other violations (sample)
No recent closed violations in the sample.
Around 1502 W Polk St
- Near West Side building violations and 311 complaints
- UIC off-campus housing: University Village renter guide
Nearby buildings with open City violation records
Nearby addresses that also have open City violation records in the City of Chicago Building Violations dataset (22u3-xenr), by distance. Open each one for its current free report.
How the winter score is calculated
- Start at 100 (better = higher).
- Minus up to 40 for open heat/boiler-related building violations (12 pts each).
- Minus up to 45 for other open building violations (2 pts each, plus extras above 20 and 100 open).
- Minus up to 20 for rodent-related open violations and 311 rodent complaints (4 pts each).
- Minus up to 15 for recent 311 building complaints (2 pts each).
- Extra −10 if 3+ open heat-related violations.
- Chicago 311 takes no-heat complaints, but the City's public 311 dataset does not publish them as a separate type, so heat here comes from open Department of Buildings heat-related violations (codes/descriptions, e.g. CN132016 HEAT UNIT ADEQUATELY). 311 building complaints are counted separately, not as heat.
- Public records only — not an inspection, appraisal, or legal advice.
Sources: City of Chicago Building Violations (data.cityofchicago.org/d/22u3-xenr); City of Chicago 311 Service Requests (data.cityofchicago.org/d/v6vf-nfxy). Data: City of Chicago (chicago.gov). Data as of November 21, 2026 at 9:13 AM CT.
ScoutMyBuilding summarizes publicly available City data. It is informational only — not legal advice, not a housing inspection, and not a guarantee of current building conditions. City records may be incomplete, delayed, or inaccurate. Always verify with the City of Chicago Department of Buildings, 311, and your own walkthrough before signing a lease.
“This site provides applications using data that has been modified for use from its original source, www.cityofchicago.org, the official website of the City of Chicago. The City of Chicago makes no claims as to the content, accuracy, timeliness, or completeness of any of the data provided at this site. The data provided at this site is subject to change at any time. It is understood that the data provided at this site is being used at one’s own risk.” Required by the City of Chicago Data Terms of Use.