Free building report
1501 W Superior St
Winter habitability score Multiple habitability signals in public records
Renter reviews
Firsthand and anonymous. Renter opinions are separate from the city records below.
No renter reviews here yet. If you’ve lived at 1501 W Superior St, yours could be the first.
Do you live here?
One tap helps other renters. The full building record stays right below.
Thanks for looking. The full record is right below.
No problem. The full record is right below.
Thanks, neighbor. Share how it’s really been — one tap on the stars is all it takes.
Thanks. Share how it really was — one tap on the stars is all it takes.
Sure, I’ll share
All open City violation records (23)
No open City violation records dated in the last 24 months (since November 2024). The newest open one is from March 7, 2013. All 23 are collapsed below — still open, still counted.
Show 23 older open City violation records (before November 2024)
- Open
CN196029 — POST OWNER/MANAGERS NAME/#
REAR BUILDING - MISSING OWNER'S ID. SIGN.
- Open
CN196019 — NO POSTED ADDRESS
REAR BUILDING - ADDRESS NOR POSTED.
- Open
CN190019 — ARRANGE PREMISE INSPECTION
INTERIOR OF BUILDING - NO ENTRY, NO RESPONSE, UNABLE TO VERIFY DETECTORS AND INTERIOR CONDITIONS.UNABLE TO INSPECT WEST BALCONIES.
- Open
CN061014 — REPAIR EXTERIOR WALL
REAR BUILDING, SOUTH AND WEST ELEVATION - WASHED OUT MORTAR.
- Open
CN064014 — REPAIR CORNICE
REAR BUILDING, EAST METAL CORNICE - RUSTED WITH HOLES AND PEELING PAINT.
- Open
CN062034 — REPAIR COPING
REAR BUILDING, WEST ELEVATION - MISSING COPING TILES.
- Open
CN072014 — SCRAPE/PAINT FIRE ESCAPE
REAR BUILDING, WEST FIRE ESCAPE - RUSTED.
- Open
CN076044 — REPAIR DOWNSPOUT
REAR BUILDING, SOUTH DOWNSPOUT - NOT CONNECTED TO GUTTER AND RUSTED.
- Open
CN104035 — MAINTAIN WINDOW
REAR BUILDING,EAST WINDOW UNITS - PEELING PAINT.EAST WINDOW FRAMES - MISSING SEALANT.
- Open
CN104055 — REPUTTY WINDOW PANES
REAR BUILDING, EAST WINDOW UNITS - DETERIORATED AND MISSING PUTTY.
- Open
CN073014 — REPAIR EXTERIOR DOOR
REAR BUILDING, EAST ENTRY DOOR - PEELING PAINT; DOOR FRAME - MISSING SEALANT.
- Open
CN073044 — REPAIR EXTERIOR DOOR HARDWARE
REAR BUILDING, EAST ENTRY DOOR - LOOSE DOOR KNOB.
- Open
CN066034 — REPAIR BALCONY
REAR BUILDING, WEST BALCONIES, GUARDRAILS ARE OF LADDER TYPE DESIGN.(OBSERVED FROM ALLEY).
- Open
CN190019 — ARRANGE PREMISE INSPECTION
NO ENTRY TO BASEMENT TO VERIFY DETECTORS
- Open
CN062024 — PARAPET
WEST ELEVATION PARAPET WALL ERODED MORTAR JOINTS AND LEANING IN TOWARDS ROOF. MASONARY PERMIT REQUIRED
- Open
CN198019 — FILE BLDG REGISTRATION
NO REGISTRATION ON FILE 1990 - 2009
- Open
CN104035 — MAINTAIN WINDOW
FLAKING AND PEELING PAINT ON ALL WINDOW FRAMES (ALL ELEVATIONS)
- Open
CN104055 — REPUTTY WINDOW PANES
WINDOW PUTTY MISSING ON MOST WINDOWS
- Open
CN104015 — REPLCE WINDOW PANES, PLEXGLAS
THREE BROKEN GLASS PANE WINDOWS WEST ELEVATION, TWO BROKEN PANE WINDOWS ON EAST ELEVATION
- Open
CN066024 — REPAIR BAY WALL
THREE BAYWALLS METAL CLAD RUSTING AND HAS HOLES
- Open
CN066034 — REPAIR BALCONY
TWO WOODEN BALCONIES ON THE WEST ELEVATION OF BUILDING ROTTED 2X10'S, ROTTED DECKING, ROTTEN GUARDRAILS, GUARD RAILS AT 32" MUST BE AT 42"
- Open
CN061014 — REPAIR EXTERIOR WALL
ERODED MORTAR JOINTS NORTH AND EAST ELEVATIONS, SEVERE STEP FRACTURES, EAST ELEVATION CENTER OF BUILDING AT GRADE
- Open
CN197019 — INSTALL SMOKE DETECTORS
NO WORKING SMOKE DETECTORS PRESENT IN STAIRWAYS
About these City violation records
From the City of Chicago Building Violations dataset description: “…informational only and does not necessarily reflect the current condition of the building or property. The dataset contains cases where a respondent has been found to be liable as well as cases where the respondent has been found to be not liable.”
311 complaints (24 months)
No matching 311 complaints in the last 24 months.
Timeline
- Open City violation record — CN066034 REPAIR BALCONY
- Open City violation record — CN073044 REPAIR EXTERIOR DOOR HARDWARE
- Open City violation record — CN073014 REPAIR EXTERIOR DOOR
- Open City violation record — CN104055 REPUTTY WINDOW PANES
- Open City violation record — CN104035 MAINTAIN WINDOW
- Open City violation record — CN076044 REPAIR DOWNSPOUT
- Open City violation record — CN072014 SCRAPE/PAINT FIRE ESCAPE
- Open City violation record — CN062034 REPAIR COPING
- Open City violation record — CN064014 REPAIR CORNICE
- Open City violation record — CN061014 REPAIR EXTERIOR WALL
- Open City violation record — CN190019 ARRANGE PREMISE INSPECTION
- Open City violation record — CN196019 NO POSTED ADDRESS
- Open City violation record — CN196029 POST OWNER/MANAGERS NAME/#
- Open City violation record — CN197019 INSTALL SMOKE DETECTORS
- Open City violation record — CN061014 REPAIR EXTERIOR WALL
- Open City violation record — CN066034 REPAIR BALCONY
- Open City violation record — CN066024 REPAIR BAY WALL
- Open City violation record — CN104015 REPLCE WINDOW PANES, PLEXGLAS
- Open City violation record — CN104055 REPUTTY WINDOW PANES
- Open City violation record — CN104035 MAINTAIN WINDOW
- Open City violation record — CN198019 FILE BLDG REGISTRATION
- Open City violation record — CN062024 PARAPET
- Open City violation record — CN190019 ARRANGE PREMISE INSPECTION
Recently closed / other violations (sample)
- Closed / other
IR0055 PROTECT METAL MEMBERS
- Closed / other
CN196029 POST OWNER/MANAGERS NAME/#
- Closed / other
IR0057 REPAIR EX. MET.
- Closed / other
IR0000 SEND EX. METAL LETTER
- Closed / other
RF301051 ARRANGE FOR RE-INSPECTION
- Closed / other
CN194019 REPAIR OR REPLACE
- Closed / other
VT1010 ARRANGE COMPLETED PERMIT INSP.
- Closed / other
IR0055 PROTECT METAL MEMBERS
- Closed / other
IR0057 REPAIR EX. MET.
- Closed / other
CN196029 POST OWNER/MANAGERS NAME/#
- Closed / other
IR0000 SEND EX. METAL LETTER
- Closed / other
IR0022 REPAIR/REPLACE LANDING SHOE
- Closed / other
IR0033 TUCK POINT RAILINGS
- Closed / other
CN062024 PARAPET
Around 1501 W Superior St
Nearby buildings with open City violation records
Nearby addresses that also have open City violation records in the City of Chicago Building Violations dataset (22u3-xenr), by distance. Open each one for its current free report.
How the winter score is calculated
- Start at 100 (better = higher).
- Minus up to 40 for open heat/boiler-related building violations (12 pts each).
- Minus up to 45 for other open building violations (2 pts each, plus extras above 20 and 100 open).
- Minus up to 20 for rodent-related open violations and 311 rodent complaints (4 pts each).
- Minus up to 15 for recent 311 building complaints (2 pts each).
- Extra −10 if 3+ open heat-related violations.
- Chicago 311 takes no-heat complaints, but the City's public 311 dataset does not publish them as a separate type, so heat here comes from open Department of Buildings heat-related violations (codes/descriptions, e.g. CN132016 HEAT UNIT ADEQUATELY). 311 building complaints are counted separately, not as heat.
- Public records only — not an inspection, appraisal, or legal advice.
Sources: City of Chicago Building Violations (data.cityofchicago.org/d/22u3-xenr); City of Chicago 311 Service Requests (data.cityofchicago.org/d/v6vf-nfxy). Data: City of Chicago (chicago.gov). Data as of November 21, 2026 at 4:36 PM CT.
ScoutMyBuilding summarizes publicly available City data. It is informational only — not legal advice, not a housing inspection, and not a guarantee of current building conditions. City records may be incomplete, delayed, or inaccurate. Always verify with the City of Chicago Department of Buildings, 311, and your own walkthrough before signing a lease.
“This site provides applications using data that has been modified for use from its original source, www.cityofchicago.org, the official website of the City of Chicago. The City of Chicago makes no claims as to the content, accuracy, timeliness, or completeness of any of the data provided at this site. The data provided at this site is subject to change at any time. It is understood that the data provided at this site is being used at one’s own risk.” Required by the City of Chicago Data Terms of Use.