1434 W Flournoy St
Winter habitability score Multiple habitability signals in public records
Renter reviews
Firsthand and anonymous. Renter opinions are separate from the city records below.
No renter reviews here yet. If you’ve lived at 1434 W Flournoy St, yours could be the first.
Do you live here?
One tap helps other renters. The full building record stays right below.
Thanks for looking. The full record is right below.
No problem. The full record is right below.
Thanks, neighbor. Share how it’s really been — one tap on the stars is all it takes.
Thanks. Share how it really was — one tap on the stars is all it takes.
Sure, I’ll share
All open City violation records (31)
No open City violation records dated in the last 24 months (since November 2024). The newest open one is from April 21, 2021. All 31 are collapsed below — still open, still counted.
Show 31 older open City violation records (before November 2024)
- Open
CN032013 — FLAMMABLE LIQUIDS 10-GAL LIMIT
BASEMENT 7 PROPANE TANKS DANGEROUS AND HAZARDOUS
- Open
CN015062 — OBSTRUCTIONS IN EXIT WAY
REAR ENCLOSED PORCH-JUNK CONSTRUCTION DEBRIS AND SUPPLIES BLOCKING EMERGENCY EGRESS AT 2 AND 3 SLIP, TRIP AND FALL HAZARD-DANGEROUS HAZARDOUS
- Open
CN104015 — REPLCE WINDOW PANES, PLEXGLAS
REAR PORCH WINDOW SASHES, FRAMES AND GLAZING REMOVED CREATING FALL HAZARD-DANGEROUS AND HAZARDOUS
- Open
NC4012 — 1-HR STAIR ENCLOSURE, <3 STORY
SOUTH/WEST STAIRS TO 3 MISSING/BROKEN DRYWALL AND PLASTER
- Open
CN012022 — 1HR FLR OVER BSMT, 1 OR 2 DU
BASEMENT MISSING BROKEN DRYWALL AND PLASTER
- Open
CN138106 — STOP/REMOVE NUISANCE
1ST FLOOR FRONT/REAR 2ND FLOOR FRONT 3RD FLOOR FRONT AND REAR SOUTH AND WEST INTERIOR STAIRS EXCESSIVE DUST DUE TO INTERIOR DEMOLITION
- Open
NC2022 — BLANK-TEXT MUST CITE CODE SECT
STOP WORK ON PREMISES UNTIL PERMIT IS OBTAINED 14A-3-306-1 14A-4-411 14A-4-401-1
- Open
NC2011 — PLANS & PERMITS REQ - CONTRCTR
INTERIOR ALTERATIONS TO AN EXISTING 3 STORY MASONRY MULTI DWELLING UNIT BUILDING INCLUDING BUT NOT LIMITED TO 1. INSTALLATION OF BEAMS AND COLUMNS AT BASEMENT 2. ERECTION OF INTERIOR PARTITIONS AT 1ST FLOOR, 2ND FLOOR FRONT, 3RD FLOOR FRONT AND REAR AND AT BASEMENT 3.REMOVAL OF PLASTER, LATHE AND DRYWALL AT SOUTH AND WEST INTERIOR STAIRWAYS
- Open
NC8012 — 1HR SEP-D.U. AND REST OF BLDG
1ST FLOOR FRONT, 2ND FLOOR FRONT, 3RD FLOOR FRONT AND REAR PENETRATIONS AT WALLS AND CEILINGS NOT PROPERLY SEALED WITH FIRE CAULK/PLASTER OPEN PENETRATIONS
- Open
VT1010 — ARRANGE COMPLETED PERMIT INSP.
18-28-106-1 INSPECTION REQUIRED ARRANGE FOR COMPLETE PERMIT INSPECTION AND OBTAIN PERMIT FOR WARM AIR HEATING SYSTEMS
- Open
VT3020 — MAINTAIN MECH. VENT SYSTEM
18-28-102 APPLICALILITY MAINTAIN MECHANICAL VENTILATION EQUIPMENT IN GOOD REPAIR AND OPERATE TO PROVIDE ADEQUITE VENTILATION REAR BASEMENT FURNACE IS HANGING FROM MOVING STRAPS MOUNTED TO CEILING JOIST VERY DANGEROUS AND HAZARDOUS ALSO THE FURNACE IS IMPROPERLY VENTED VERY DANGEROUS AND HAZARDOUS
- Open
VT2010 — SUBMIT PLANS/GET VENT PERMIT
13-32-010 PERMIT REQUIRED 13-32-130 OPERATIONS WITHOUT PERMIT #1 SUBMIT PLANS AND OBTAIN VENTILATING SYSTEM PERMIT NO PLANS SUBMITTED FOR ALL NOW HVAC WORK THROUGHTOUT
- Open
CN199029 — Violation
13-32-010 PERMIT REQUIRED WORK CANNOT PROCEED WITHOUT FIRST OBTAINING A PERMIT (VT2051)IS INCORRECT
- Open
PL171027 — LICENSED BONDED PLMBG CONTRCTR
EMPLOY LICENSED AND BONDED PLUMBER TO PERFORM PLUMBING WORK 18-29-106-1 THRU 106-2
- Open
CN197019 — INSTALL SMOKE DETECTORS
WEST/SOUTH STAIRWAYS AT TOP AND BASEMENT, NORTH ENCLOSED PORCH UNIT 1 NORTH NO SMOKE DETECTORS
- Open
PL232040 — RMV PLBFIX INSTALLD W/0 PERMIT
REMOVE PLUMBING FIXTURES WATER SUPPLY SOIL WASTE AND VENT PIPING INSTALLED WITHOUT PERMIT ABOVE GROUND AND UNDERGROUND 13-12-050 13-32-010
- Open
PL157047 — STOP LEAKING WATER
STOP LEAKING WATER PIPES FROM 1 FRONT IS LEAKING IN GARDEN FLAT 1ST BATHROOM 18-29-102-3
- Open
PL161027 — SEAL DRAIN OPENING UNUSD FIXTR
SEAL OPEN DRAINS FROM REMOVAL OF PLUMBING FIXTUR THROUGHOUT ENTIRE BUILDING AND STOP AND ODORS
- Open
EL1805 — DEFECTIVE DISTRIBUTION
DISTRIBUTION HAS BRANCH CIRCUITS AND FEEDER MIXED DANGEROUS HAZARDOUS
- Open
EL1823 — INSTALL COVERS
INSTALL COVERS IN ALL OPENINGS IN PANELS AND DISTRIBUTIONS
- Open
EL1829 — EXPOSED WIRING
REMOVE ALL EXPOSED WIRING IN BASEMENT AND ALL OTHER AREAS
- Open
EL1845 — REMOVE TEMPS
REMOVE ALL EXPOSED NON GFC1 PROTECTED TEMP WIRING DANGEROUS AND HAZARDOUS
- Open
EL1836 — PANEL SCHEDULES
PROVIDE PANEL SCHEDULES IN BASEMENT AND IN UNITS
- Open
EL1824 — INSTALL ILLUMINATION
PROVIDE LIGHTING TO ALL HALLWAY FRONT AND REAR DANGEROUS AND HAZARDOUS
- Open
EL1857 — SMOKE & CARBON DETECTORS
INSTALL REQUIRIED SMOKE AND CARBON MONOXIDE DETECTORS INSTALL UNITS AND HALLWAYS DANGEROUS AND HAZARDOUS
- Open
EL1830 — ARMORED CABLE
REMOVE DEFECTIVE ARMORED CABLE IN THE BASEMENT AND THOUGH OUT BUILDING
- Open
EL1875 — INSTALL GFCI'S
INSTALL GFCI PROTECTION IN UNFINISH BASEMENT AND ALL OTHER REQUIRED LOCATIONS
- Open
EL1825 — SYSTEM III
INSTALL SYSTEM 3 EM LIGHTING IN ALL HALLWAYS AND BASEMENTS DANGEROUS AND HAZARDOUS
- Open
EL1817 — CONTINUITY OF RACEWAYS
REPAIR ALL INCOMPLETE CONDUIT RUNS THROUGHOUT BUILDING SPECIFICALLY FEEDER FOR UNIT 3F DANGEROUS AND HAZARDOUS
- Open
PL171017 — OBTN PERMIT FOR PLUMBING WORK
OBTAIN PERMIT FOR PLUMBING WORK BEFORE UNDERTAKING WORK 18-29-106-1
- Open
CN197087 — CARB MONOX DETECT IN RESID
UNIT 1 NORTH, BASEMENT NO CARBON MONOXIDE DETECTORS
About these City violation records
From the City of Chicago Building Violations dataset description: “…informational only and does not necessarily reflect the current condition of the building or property. The dataset contains cases where a respondent has been found to be liable as well as cases where the respondent has been found to be not liable.”
311 complaints (24 months)
No matching 311 complaints in the last 24 months.
Timeline
- Open City violation record — CN197087 CARB MONOX DETECT IN RESID
- Open City violation record — PL171017 OBTN PERMIT FOR PLUMBING WORK
- Open City violation record — EL1817 CONTINUITY OF RACEWAYS
- Open City violation record — EL1825 SYSTEM III
- Open City violation record — EL1875 INSTALL GFCI'S
- Open City violation record — EL1830 ARMORED CABLE
- Open City violation record — EL1857 SMOKE & CARBON DETECTORS
- Open City violation record — EL1824 INSTALL ILLUMINATION
- Open City violation record — EL1836 PANEL SCHEDULES
- Open City violation record — EL1845 REMOVE TEMPS
- Open City violation record — EL1829 EXPOSED WIRING
- Open City violation record — EL1823 INSTALL COVERS
- Open City violation record — EL1805 DEFECTIVE DISTRIBUTION
- Open City violation record — PL161027 SEAL DRAIN OPENING UNUSD FIXTR
- Open City violation record — PL157047 STOP LEAKING WATER
- Open City violation record — PL232040 RMV PLBFIX INSTALLD W/0 PERMIT
- Open City violation record — CN197019 INSTALL SMOKE DETECTORS
- Open City violation record — PL171027 LICENSED BONDED PLMBG CONTRCTR
- Open City violation record — CN199029
- Open City violation record — VT2010 SUBMIT PLANS/GET VENT PERMIT
- Open City violation record — VT3020 MAINTAIN MECH. VENT SYSTEM
- Open City violation record — VT1010 ARRANGE COMPLETED PERMIT INSP.
- Open City violation record — NC8012 1HR SEP-D.U. AND REST OF BLDG
- Open City violation record — NC2011 PLANS & PERMITS REQ - CONTRCTR
- Open City violation record — NC2022 BLANK-TEXT MUST CITE CODE SECT
- Open City violation record — CN138106 STOP/REMOVE NUISANCE
- Open City violation record — CN012022 1HR FLR OVER BSMT, 1 OR 2 DU
- Open City violation record — NC4012 1-HR STAIR ENCLOSURE, <3 STORY
- Open City violation record — CN104015 REPLCE WINDOW PANES, PLEXGLAS
- Open City violation record — CN015062 OBSTRUCTIONS IN EXIT WAY
- Open City violation record — CN032013 FLAMMABLE LIQUIDS 10-GAL LIMIT
Recently closed / other violations (sample)
- Closed / other
VT1010 ARRANGE COMPLETED PERMIT INSP.
- Closed / other
PL151137 OPEN
Around 1434 W Flournoy St
- Near West Side building violations and 311 complaints
- UIC off-campus housing: University Village renter guide
Nearby buildings with open City violation records
Nearby addresses that also have open City violation records in the City of Chicago Building Violations dataset (22u3-xenr), by distance. Open each one for its current free report.
How the winter score is calculated
- Start at 100 (better = higher).
- Minus up to 40 for open heat/boiler-related building violations (12 pts each).
- Minus up to 45 for other open building violations (2 pts each, plus extras above 20 and 100 open).
- Minus up to 20 for rodent-related open violations and 311 rodent complaints (4 pts each).
- Minus up to 15 for recent 311 building complaints (2 pts each).
- Extra −10 if 3+ open heat-related violations.
- Chicago 311 takes no-heat complaints, but the City's public 311 dataset does not publish them as a separate type, so heat here comes from open Department of Buildings heat-related violations (codes/descriptions, e.g. CN132016 HEAT UNIT ADEQUATELY). 311 building complaints are counted separately, not as heat.
- Public records only — not an inspection, appraisal, or legal advice.
Sources: City of Chicago Building Violations (data.cityofchicago.org/d/22u3-xenr); City of Chicago 311 Service Requests (data.cityofchicago.org/d/v6vf-nfxy). Data: City of Chicago (chicago.gov). Data as of November 21, 2026 at 9:23 AM CT.
ScoutMyBuilding summarizes publicly available City data. It is informational only — not legal advice, not a housing inspection, and not a guarantee of current building conditions. City records may be incomplete, delayed, or inaccurate. Always verify with the City of Chicago Department of Buildings, 311, and your own walkthrough before signing a lease.
“This site provides applications using data that has been modified for use from its original source, www.cityofchicago.org, the official website of the City of Chicago. The City of Chicago makes no claims as to the content, accuracy, timeliness, or completeness of any of the data provided at this site. The data provided at this site is subject to change at any time. It is understood that the data provided at this site is being used at one’s own risk.” Required by the City of Chicago Data Terms of Use.