Free building report
1421 W Chicago Ave
Winter habitability score Some issues on record — read the details
Renter reviews
Firsthand and anonymous. Renter opinions are separate from the city records below.
No renter reviews here yet. If you’ve lived at 1421 W Chicago Ave, yours could be the first.
Do you live here?
One tap helps other renters. The full building record stays right below.
Thanks for looking. The full record is right below.
No problem. The full record is right below.
Thanks, neighbor. Share how it’s really been — one tap on the stars is all it takes.
Thanks. Share how it really was — one tap on the stars is all it takes.
Sure, I’ll share
All open City violation records (18)
No open City violation records dated in the last 24 months (since November 2024). The newest open one is from September 26, 2016. All 18 are collapsed below — still open, still counted.
Show 18 older open City violation records (before November 2024)
- Open
CN131016 — SCREEN OUTER DOORS, WINDOWS
FRONT AND REAR BUILDINGS - MISSING WINDOW AND REAR DOOR SCREENS.
- Open
CN190020 — INSPECT CONSTRUCTION WORK
RECENTLY BUILT STEEL PORCH/PLATFORM. PLANS AND PERMIT #100571686 (ISSUED 12/2/2014) NOT AVAILABLE FOR REVIEW AT TIME OF INSPECTION.
- Open
CN190019 — ARRANGE PREMISE INSPECTION
UNABLE TO INSPECT INTERIOR, STAIRWELL, APARTMENTS, AND BASEMENT. UNVERIFIED DETECTORS AND OCCUPANCY.
- Open
PL164037 — PRV CAST IRON COVER FOR BASIN
BASEMENT LEVEL - COVER MISSING AT NOW DEFUNCT CATCH BASIN; COVERED WITH AUTOMOBILE TIRE.
- Open
CN074014 — SERVICE WALK, PASSAGE, AREAWAY
DANGEROUS AND HAZARDOUS - REAR AREA WAY SERVICE WALK WHICH PROVIDES 2ND MEANS OF EGRESS FOR FRONT AND REAR BUILDINGS HAS COLLAPSED. PLANS AND PERMITS AND STRUCTURAL ENGINEERS REPORT ARE REQUIRED FOR REPAIRS
- Open
NC3022 — ADDITIONAL EXIT
REAR BUILDING, 1ST FLOOR COMMERCIAL SPACE OF FRONT BUILDING AND REAR 3 RESIDENTIAL UNITS OF FRONT BUILDING DO NOT MEET THE REQUIRED MEANS OF EGRESS PER THE CHICAGO BUILDING CODE SECTIONS 13-160-050 AND 13-196-050 CREATING A DANGEROUS AND HAZARDOUS CONDITION FOR ANY INHABITANTS OF THOSE SPACES.AND ANY FIRST RESPONDER AND SHALL REMAIN VACANT UNTIL THE EGRESS ISSUES ARE RESOLVED WITH PROPER AND APPROVED PLANS/ PERMITS AND STRUCTURAL ENGINEERS REPORT.
- Open
CN061024 — SUBMIT 2 COPY STRUCTURAL RPT
PROVIDE A STRUCTURAL ENGINEERS REPORT FOR THE STRUCTURAL STABILITY OF FOUNDATIONS OF FRONT AND REAR BUILDINGS AND OVER ALL STRUCTURAL STABILITY OF FRONT AND REAR BUILDINGS AND FOR REPAIRS OF REAR AREA WAY TO RESTORE EGRESS TO AFFECTED UNITS.
- Open
NC2011 — PLANS & PERMITS REQ - CONTRCTR
PROVIDE PLAN AND ALL REQUIRED PERMITS TO MAKE REPAIRS TO REAR AREA WAY AND TO RESTORE 2NED MEANS OF EGRESS TO AFFECTED AREAS.
- Open
CN065014 — REPAIR LINTELS
ROTTED AND UNSTABLE LINTEL ABOVE GRONT BASEMENT WINDOW
- Open
CN061014 — REPAIR EXTERIOR WALL
WASHED-OUT AND ERODED MORTAR JOINTS THRU-OUT
- Open
CN197019 — INSTALL SMOKE DETECTORS
MISSING SMOKE DETECTORS.
- Open
CN197087 — CARB MONOX DETECT IN RESID
MISSING CARBON MONOXIDE DETECTOR
- Open
CN194019 — REPAIR OR REPLACE
1ST FLOOR SYSTEM DOES NOT MEET THE LOAD REQUIREMENTS OF SECTION (16(13-52-090) DUE TO ROTTED JOIST,UNDER SIZED JOIST AND ROTTED AND UNDERSIZED BEAM AND COLUMN SYSTEM
- Open
NC2011 — PLANS & PERMITS REQ - CONTRCTR
PROVIDE PLANS AND ALL REQUIRED PERMITS TO MAKE REPAIRS TO BUILDING.
- Open
IR0055 — PROTECT METAL MEMBERS
PROTECT METAL MEMBERS
- Open
IR0000 — SEND EX. METAL LETTER
EXPOSED METAL LETTER
- Open
CN190019 — ARRANGE PREMISE INSPECTION
NO ENTRY FOR ANNUAL INSPECTION
- Open
CN190019 — ARRANGE PREMISE INSPECTION
ARRANGE FOR INTERIOR INSPECTION TO VERIFY OCCUPANCY
About these City violation records
From the City of Chicago Building Violations dataset description: “…informational only and does not necessarily reflect the current condition of the building or property. The dataset contains cases where a respondent has been found to be liable as well as cases where the respondent has been found to be not liable.”
311 complaints (24 months)
No matching 311 complaints in the last 24 months.
Timeline
- Open City violation record — CN131016 SCREEN OUTER DOORS, WINDOWS
- Open City violation record — PL164037 PRV CAST IRON COVER FOR BASIN
- Open City violation record — CN190019 ARRANGE PREMISE INSPECTION
- Open City violation record — CN190020 INSPECT CONSTRUCTION WORK
- Open City violation record — NC2011 PLANS & PERMITS REQ - CONTRCTR
- Open City violation record — CN194019 REPAIR OR REPLACE
- Open City violation record — CN197087 CARB MONOX DETECT IN RESID
- Open City violation record — CN197019 INSTALL SMOKE DETECTORS
- Open City violation record — CN061014 REPAIR EXTERIOR WALL
- Open City violation record — CN065014 REPAIR LINTELS
- Open City violation record — NC2011 PLANS & PERMITS REQ - CONTRCTR
- Open City violation record — CN061024 SUBMIT 2 COPY STRUCTURAL RPT
- Open City violation record — NC3022 ADDITIONAL EXIT
- Open City violation record — CN074014 SERVICE WALK, PASSAGE, AREAWAY
- Open City violation record — IR0000 SEND EX. METAL LETTER
- Open City violation record — IR0055 PROTECT METAL MEMBERS
- Open City violation record — CN190019 ARRANGE PREMISE INSPECTION
- Open City violation record — CN190019 ARRANGE PREMISE INSPECTION
Recently closed / other violations (sample)
- Closed / other
EL0023 INSTALL COVERS
- Closed / other
CN010012 1-HR HEATING PLANT ENCLOSURE
- Closed / other
CN101015 REPAIR INTERIOR WALLS/CEILING
- Closed / other
CN031023 FIRE EXTNGSHR RECHARGE & TAG
- Closed / other
IR0000 SEND EX. METAL LETTER
- Closed / other
CN061034 FLAKY INTERIOR PAINT
- Closed / other
CN198019 FILE BLDG REGISTRATION
- Closed / other
CN061014 REPAIR EXTERIOR WALL
- Closed / other
CN196029 POST OWNER/MANAGERS NAME/#
Around 1421 W Chicago Ave
Nearby buildings with open City violation records
Nearby addresses that also have open City violation records in the City of Chicago Building Violations dataset (22u3-xenr), by distance. Open each one for its current free report.
How the winter score is calculated
- Start at 100 (better = higher).
- Minus up to 40 for open heat/boiler-related building violations (12 pts each).
- Minus up to 45 for other open building violations (2 pts each, plus extras above 20 and 100 open).
- Minus up to 20 for rodent-related open violations and 311 rodent complaints (4 pts each).
- Minus up to 15 for recent 311 building complaints (2 pts each).
- Extra −10 if 3+ open heat-related violations.
- Chicago 311 takes no-heat complaints, but the City's public 311 dataset does not publish them as a separate type, so heat here comes from open Department of Buildings heat-related violations (codes/descriptions, e.g. CN132016 HEAT UNIT ADEQUATELY). 311 building complaints are counted separately, not as heat.
- Public records only — not an inspection, appraisal, or legal advice.
Sources: City of Chicago Building Violations (data.cityofchicago.org/d/22u3-xenr); City of Chicago 311 Service Requests (data.cityofchicago.org/d/v6vf-nfxy). Data: City of Chicago (chicago.gov). Data as of November 21, 2026 at 7:03 PM CT.
ScoutMyBuilding summarizes publicly available City data. It is informational only — not legal advice, not a housing inspection, and not a guarantee of current building conditions. City records may be incomplete, delayed, or inaccurate. Always verify with the City of Chicago Department of Buildings, 311, and your own walkthrough before signing a lease.
“This site provides applications using data that has been modified for use from its original source, www.cityofchicago.org, the official website of the City of Chicago. The City of Chicago makes no claims as to the content, accuracy, timeliness, or completeness of any of the data provided at this site. The data provided at this site is subject to change at any time. It is understood that the data provided at this site is being used at one’s own risk.” Required by the City of Chicago Data Terms of Use.