Free building report

1419 W TAYLOR ST

Winter habitability score Some issues on record — read the details

Download a PDF of this report

Renter reviews

Firsthand and anonymous. Renter opinions are separate from the city records below.

No renter reviews here yet. If you’ve lived at 1419 W Taylor St, yours could be the first.

A Chicago three-flat

Do you live here?

One tap helps other renters. The full building record stays right below.

Sure, I’ll share
How’s it been living here? Required

Tap a star — 1 is rough, 5 is great.

Add more detail (optional — heat, pests, repairs, noise, management)

Tap 1 to 5 for any you want. 1 is rough, 5 is great. Skip the rest.

Heat Warm enough when it counts?
Pests Have pests been a problem?
Maintenance responsiveness When something broke, how fast did it get fixed?
Noise How noisy was it, day to day?
Management How they treated you and answered you
Would you rent here again?

Your own experience only — no fake or paid reviews. Shown anonymously after you confirm and a person approves it. Review policy · Terms

7Open City violation records
1Open heat-related City records
0311 rodent (24 mo)
0311 building (24 mo)

What rat complaints mean →

All open City violation records (7)

No open City violation records dated in the last 24 months (since November 2024). The newest open one is from November 3, 2023. All 7 are collapsed below — still open, still counted.

Show 7 older open City violation records (before November 2024)
  • Open

    CN012022 — 1HR FLR OVER BSMT, 1 OR 2 DU

    THE BASEMENT CEILING IS NOT FIRE SEPARATED WITH FIRE RESISTIVE MATERIAL. DANGEROUS AND HAZARDOUS. PLANS / PERMITS REQUIRED TO INSTALL FIRE RATED MATERIAL ACCROSS THE BASEMENT CEILING IN ITS' ENTIRETY.SECTION 14B-6-605.4

  • Open

    CN197019 — INSTALL SMOKE DETECTORS

    THE BASEMENT, 1ST AND 2CD FLOORS HAVE NO SMOKE DETECTORS. DANGEROUS AND HAZARDOUS.SECTION 14X-5-504.8

  • Open

    PL157047 — STOP LEAKING WATER

    THE BASEMENT BELOW THE LICENSED RESTARAUNT HAS A SIGNIFICANT FLOODING PROBLEM. THERE IS STANDING WATER COVERING 75% OF THE BASEMENT FLOOR. UNSANITARY AND DANGEROUS / HAZARDOUS.SECTION 14X-9-902 / 903 / 905 / 908.

  • Heat-related

    CN010012 — 1-HR HEATING PLANT ENCLOSURE

    THE BASEMENT GAS FIRED FURNACE AND WATER HEATER ARE NOT ENCLOSED WITH FIRE RATED MATERIAL OR A FIRE RATED DOOR. DANGEROUS AND HAZARDOUS. PLANS / PERMIT REUIRED TO CONSTRUCT THIS ENCLOSURE.SECTION 14B-5-509

  • Open

    NC2011 — PLANS & PERMITS REQ - CONTRCTR

    THE 1ST FLOOR IS A LICENSED RESTARAUNT. THERE ARE 2 STAIR FLIGHTS THAT CONNECT THE 1ST FLOOR TO A 2CD FLOOR SPACE THAT HAS BEEN ALTERED INTO A NOW EXISTING UNLICENSED EVENT SPACE. TICKETS ARE BEING SOLD ONLINE AS WELL AS FOOD / ALCOHOL SERVED / SOLD. THERE ARE NO PLANS / PERMITS / APPLICATIONS TO OPERATE A 2CD FLOOR PPA EVENT SPACE. THERE ARE NO PLANS / PERMITS ON FILE FOR THE RENOVATION OF THIS 2CD FLOOR SPACE. THERE ARE NEW PLUMBING / ELECTRICAL FIXTURES WITH ASSOCIATED PIPING / WIRING. BOTH DOB AND BACP HAVE ISSUED CLOSYRES FOR THIS UNLICENSED 2CD FLOOR SPACE.SECTION 14A-4-401.1

  • Open

    CN071014 — REPAIR EXTERIOR PLATFORM

    THE ROOF AREA HAS HAD A PLATFORM STRUCTURE BUILT TO SUPPORT VARIOUS (HEAVY) HVAC EQUIPMENT. THE PLATFORM ITSELF HAS A ROOF. THIS PLATFORM ROOF STRUCTURE HAS ROTTED ROOF SHEATHING AND ROTTED ROOF RAFTERS. A MAKE SHIFT 4"X4" COLUMN WITHOUT A PROPER FOOTING HAS BEEN INSTALLED TO SHORE UP THIS FAILING STRUCTURE. THERE IS A STRUCTURAL LEDGER BEAM ASSOCIATED WITH THIS ROOF STRUCTURE THAT IS ATTACHED TO THE MAIN BUILDING WITH NAILS AND NOT SHEAR RESISTANT STRUCTURAL BOLTS. DANGEROUS AND HAZARDOUS. PLANS / PERMITS REQUIRED TO REPAIR OR REPLACE THIS EXTERIOR STRUCTURE.SECTIONJ 14X-3-303.1

  • Open

    CN197089 — CARB MONOX DETECT IN ASSEMBLY

    THE BASEMENT, 1ST AND 2CD FLOORS HAVE NO CARBON MONOXIDE DETECTORS. DANGEROUS AND HAZARDOUS.SECTION 14X-5-504.9

About these City violation records

From the City of Chicago Building Violations dataset description: “…informational only and does not necessarily reflect the current condition of the building or property. The dataset contains cases where a respondent has been found to be liable as well as cases where the respondent has been found to be not liable.”

↑ Back to renter reviews

311 complaints (24 months)

No matching 311 complaints in the last 24 months.

Timeline

  1. Open City violation record — CN197089 CARB MONOX DETECT IN ASSEMBLY
  2. Open City violation record — CN071014 REPAIR EXTERIOR PLATFORM
  3. Open City violation record — NC2011 PLANS & PERMITS REQ - CONTRCTR
  4. Open heat-related City violation record — CN010012 1-HR HEATING PLANT ENCLOSURE
  5. Open City violation record — PL157047 STOP LEAKING WATER
  6. Open City violation record — CN197019 INSTALL SMOKE DETECTORS
  7. Open City violation record — CN012022 1HR FLR OVER BSMT, 1 OR 2 DU

Recently closed / other violations (sample)

  • Closed / other

    NC2021 PERMIT REQUIRED - CONTRACTOR

  • Closed / other

    NC2022 BLANK-TEXT MUST CITE CODE SECT

  • Closed / other

    CN039013 POST APPROVED OCCUPANCY CARD

Around 1419 W Taylor St

Nearby buildings with open City violation records

Nearby addresses that also have open City violation records in the City of Chicago Building Violations dataset (22u3-xenr), by distance. Open each one for its current free report.

How the winter score is calculated
  1. Start at 100 (better = higher).
  2. Minus up to 40 for open heat/boiler-related building violations (12 pts each).
  3. Minus up to 45 for other open building violations (2 pts each, plus extras above 20 and 100 open).
  4. Minus up to 20 for rodent-related open violations and 311 rodent complaints (4 pts each).
  5. Minus up to 15 for recent 311 building complaints (2 pts each).
  6. Extra −10 if 3+ open heat-related violations.
  7. Chicago 311 takes no-heat complaints, but the City's public 311 dataset does not publish them as a separate type, so heat here comes from open Department of Buildings heat-related violations (codes/descriptions, e.g. CN132016 HEAT UNIT ADEQUATELY). 311 building complaints are counted separately, not as heat.
  8. Public records only — not an inspection, appraisal, or legal advice.

Sources: City of Chicago Building Violations (data.cityofchicago.org/d/22u3-xenr); City of Chicago 311 Service Requests (data.cityofchicago.org/d/v6vf-nfxy). Data: City of Chicago (chicago.gov). Data as of November 21, 2026 at 7:59 AM CT.

ScoutMyBuilding summarizes publicly available City data. It is informational only — not legal advice, not a housing inspection, and not a guarantee of current building conditions. City records may be incomplete, delayed, or inaccurate. Always verify with the City of Chicago Department of Buildings, 311, and your own walkthrough before signing a lease.

“This site provides applications using data that has been modified for use from its original source, www.cityofchicago.org, the official website of the City of Chicago. The City of Chicago makes no claims as to the content, accuracy, timeliness, or completeness of any of the data provided at this site. The data provided at this site is subject to change at any time. It is understood that the data provided at this site is being used at one’s own risk.” Required by the City of Chicago Data Terms of Use.

Check another address

Help: hello@scoutmybuilding.com