1315 E 52nd St
Winter habitability score Many open City violation records and/or complaint activity
Renter reviews
Firsthand and anonymous. Renter opinions are separate from the city records below.
No renter reviews here yet. If you’ve lived at 1315 E 52nd St, yours could be the first.
Do you live here?
One tap helps other renters. The full building record stays right below.
Thanks for looking. The full record is right below.
No problem. The full record is right below.
Thanks, neighbor. Share how it’s really been — one tap on the stars is all it takes.
Thanks. Share how it really was — one tap on the stars is all it takes.
Sure, I’ll share
All open City violation records (39)
13 of 39 open City violation records are from the last 24 months (since November 2024), shown newest first. 26 older ones are collapsed below — still open, still counted.
- Open
CN101015 — REPAIR INTERIOR WALLS/CEILING
#1315/UNIT #1W/FRONT BATHROOM - LARGE HOLE IN CEILING; PLUMBING PIPES EXPOSED; WATER LEAKING; LOOSE FALLING DRYWALL/PLASTER; PAINT PEELINGREAR BATHROOM - HOLE IN CEILING; WATER LEAKING; BLACK SUBSTANCE ON CEILING;DININGROOM - WATER DAMAGE AT CEILING CROWN; SATURATED THROUGHOUT; LIVINGROOM - PAINT BUBBLING BELOW WINDOW; BASEBOARDS DAMAGED BY WATER - ROTTING; BUCKLING, CRACKED WALLS AND CEILINGS THROUGHOUT UNIT;#1315/INTERIOR STAIRWELL/WALLS, CEILINGS - CRACKED, BUCKLING AT 3RD FLOOR; HOLE AT 3RD FLOOR (14X-3-304.3)
- Open
CN031023 — FIRE EXTNGSHR RECHARGE & TAG
#1315 INTERIOR STAIRWELL/FIRE EXTINGUISHERS - MAINTENANCE TAG MISSING AT 1ST & 2ND FLOOR; EXTINGUISHER MISSING AT 3RD FLOOR (14X-5-504.5)
- Open
CN197079 — REPAIR/REPLACE SMOKE DETECTORS
#1315 INTERIOR STAIRWELL/2ND FLOOR/SMOKE DETECTOR - NOT WORKING AT TIME OF INSPECTION; BEEPING (14X-5-504.8)
- Open
CN015062 — OBSTRUCTIONS IN EXIT WAY
UNIT #1315-1W/HALLWAYS - EXCESSIVE STORAGE THROUGHOUT UNIT OBSTRUCTING PASSAGEWAYS (14X-5-505.1.2)
- Open
CN103015 — REPAIR FLOOR
UNIT #1315-1W/LIVINGROOM - HARDWOOD FLOOR - BUCKLING; TRIP HAZARD (14X-3-304.4)
- Open
CN102015 — INT WALL/CEILING PEELING PAINT
#1315-UNIT 1W/REAR BATHROOM - BLACK SUBSTANCE ON CEILING; ROTTING CEILING CROWN AND BASEBAORDS THROUGHOUT (14X-3-304.3)
- Open
CN061034 — FLAKY INTERIOR PAINT
#1315/UNIT #1W - PAINT PEELING, BUBBLING THROUGHOUT UNIT (14X-3-303.2)
- Open
PL157047 — STOP LEAKING WATER
#1315/UNIT #1W/BATHROOMS, LIVINGROOM, DININGROOM - WATER LEAKING AT CEILING THROUGHOUT;#1315/INTERIOR STAIRWELL - WATER LEAKING AT 3RD FLOOR CEILING (14X-9-904.1)
- Open
CN061064 — BUILDING IN DISREPAIR
#1315/UNIT #1W/FRONT BATHROOM - LARGE HOLE IN CEILING; PLUMBING PIPES EXPOSED; WATER LEAKING; LOOSE FALLING DRYWALL/PLASTER; PAINT PEELING (14A-3-315)
- Open
CN138106 — STOP/REMOVE NUISANCE
REAR PORCH DECKS ARE STORING GARBAGE, HOUSEHOLD BELONGINGS AND BBQ GRILLS. 14X-1-103
- Open
CN190019 — ARRANGE PREMISE INSPECTION
INTERIOR OF UNITS - NO ENTRY, UNVERIFIED DETECTORS AND CONDITIONS. UNABLE TO VERIFY COMPLAINT FOR BEDBUG INFESTATION THROUGHOUT THE BUILDING. 14A-1-104.7
- Open
CN061014 — REPAIR EXTERIOR WALL
REAR ELEVATION AT PORCH STAIRS / 2ND FLOOR EXTERIOR WALL HAS MASONRY FRACTURES AT WOOD BEAM LOCATION. 14X-3-303.6
- Open
CN070024 — REPAIR PORCH SYSTEM
SOUTH ELEVATION / 3 STORY WOOD PORCH / LEDGER BOARD AT 1ST FLOOR IS FASTENED WITH NAILS ONLY. DECKING IS WEATHERED, WARPED WITH POPPED NAILS AND GAPS AT TOP JOISTS. STAIR LANDING GUARDRAIL IS MISSING PICKET. 14X-3-303.11
Show 26 older open City violation records (before November 2024)
- Open
NC2021 — PERMIT REQUIRED - CONTRACTOR
OBTAIN PERMIT FOR MASONRY WORK
- Open
CN070024 — REPAIR PORCH SYSTEM
REAR PORCH GUARDRAILS LESS THAN 42 HAND RAILS UNDER 34. 42 FOUNDATIONS REQ WITH POSTIVE ATTACHMENT TO COLUMNS. INSUFFICENT LEDGER BOLTS AT LANDINGS. JOIST OVERSPANNED ANDGLE BRACES SUPPORTING JOISTS RUSTED. STRINGERS UNDERSIZED WEAK CONNECTIONS AT LANDINGS. OBTAIN PLANS AND PERMITS TO REPAIR PORCH.
- Open
CN065014 — REPAIR LINTELS
NORTH ELEVATION LINTELS RUSTED DETERIORATED
- Open
CN061014 — REPAIR EXTERIOR WALL
NORTH LOOSE BRICKS ABOVE LINTELS
- Open
CN061034 — FLAKY INTERIOR PAINT
WINDOW FRAMES PEELING PAINT
- Open
CN104055 — REPUTTY WINDOW PANES
CRACKED MISSING PUTTY LOOSE PANES
- Open
CN065034 — REPAIR WINDOW SILLS
LIMESTONE SILLS MISISNG MORTAR
- Open
CN104025 — MAINTAIN WINDOW SASH
SOUTH EAST WEST ROTTED SASH
- Open
CN190019 — ARRANGE PREMISE INSPECTION
ARRANGE INTERIROR INSPECTION
- Open
CN062024 — PARAPET
NORTH PARAPET WITH BULGING MASONRY
- Open
CN070024 — REPAIR PORCH SYSTEM
REAR PORCH SYSTEM: GUARDRAILS AND HEADRAILS TOO LOW, NO ANGLE BRACKETS AT BEAMS, TREADS NOT 10 1/2", STRINGERS NOT BOLTED, 3/8" BOLTS AT LEDGERS TOO SMALL, ONLY 2 AT LANDING, NO FOOTINGS, NO ANCHOR BRACKETS, NO BOLTS AT SPLICE
- Open
PL153017 — REPLACE DEFECTIVE FAUCET
LAUNDRY ROOM SINK COLD WATER FAUCET INOPERABLE
- Open
CN101015 — REPAIR INTERIOR WALLS/CEILING
INTERIOR CEILINGS COLLAPSED AND DAMAGED, 1315, BASEMENT, 2 LOCATIONS, 1319, 2ND FLOOR, FRONT ROOM, BATHROOM, & 1321, 3RD FLOOR KITCHEN
- Open
PL154027 — SUPPLY HOT WTR MIN TEMP 120DEG
1321, 3RD FLOOR APT, FRONT & REAR BATHROOM SINKS, NO HOT WATER
- Open
NC2011 — PLANS & PERMITS REQ - CONTRCTR
PLANS NEEDED FOR PORCH(MAY BE AVAILABLE ONLINE AT WWW.CITYOFCHICAGO.ORG)
- Open
CN077014 — REPAIR FENCE
FENCE COLLAPSED, UNMOUNTED TOP RAIL:REAR YARD
- Open
CN065014 — REPAIR LINTELS
RUSTED, BOWING, OR DETERIORATING LINTELS, ALL LEVELS, NORTH ELEVATIONS
- Heat-related
PL155027 — PROVIDE HOT WATER TO FIXTURES
1321, 3RD FLOOR APT, FRONT & REAR BATHROOM SINK, NO COLD WATER
- Open
CN197019 — INSTALL SMOKE DETECTORS
NO SMOKE DETECTORS TOP OF STAIRWELL, 1321
- Open
CN108015 — REPAIR SKYLIGHT
TORN OR MISSING SCREENS: ALL LEVELS, ALL ELEVATIONS
- Open
CN104035 — MAINTAIN WINDOW
ROTTED FRAMES: ALL WINDOWS
- Open
CN104025 — MAINTAIN WINDOW SASH
ROTTED SASHES: ALL WINDOWS
- Open
CN198019 — FILE BLDG REGISTRATION
REGISTER BUILDING WITH DOB , ALL YEARS
- Open
CN065034 — REPAIR WINDOW SILLS
ROTTED SILLS: ALL WINDOWS
- Open
CN104055 — REPUTTY WINDOW PANES
DRIED, LOOSE, MISSING PUTTY: ALL WINDOWS
- Open
CN061034 — FLAKY INTERIOR PAINT
ALL EXTERIOR TRIM, WINDOW FRAMES, SASHES, SILLS:LOOSE PAINT
About these City violation records
From the City of Chicago Building Violations dataset description: “…informational only and does not necessarily reflect the current condition of the building or property. The dataset contains cases where a respondent has been found to be liable as well as cases where the respondent has been found to be not liable.”
311 complaints (24 months)
- building
Buildings - Plumbing Violation
- building
Building Violation
- building
Building Violation
- rodent
Rodent Baiting/Rat Complaint
Timeline
- Open City violation record — CN061064 BUILDING IN DISREPAIR
- Open City violation record — PL157047 STOP LEAKING WATER
- Open City violation record — CN061034 FLAKY INTERIOR PAINT
- Open City violation record — CN102015 INT WALL/CEILING PEELING PAINT
- Open City violation record — CN103015 REPAIR FLOOR
- Open City violation record — CN015062 OBSTRUCTIONS IN EXIT WAY
- Open City violation record — CN197079 REPAIR/REPLACE SMOKE DETECTORS
- Open City violation record — CN031023 FIRE EXTNGSHR RECHARGE & TAG
- Open City violation record — CN101015 REPAIR INTERIOR WALLS/CEILING
- 311 building — Building Violation
- 311 building — Buildings - Plumbing Violation
- Open City violation record — CN070024 REPAIR PORCH SYSTEM
- Open City violation record — CN061014 REPAIR EXTERIOR WALL
- Open City violation record — CN190019 ARRANGE PREMISE INSPECTION
- Open City violation record — CN138106 STOP/REMOVE NUISANCE
- 311 building — Building Violation
- 311 rodent — Rodent Baiting/Rat Complaint
- Open City violation record — CN062024 PARAPET
- Open City violation record — CN190019 ARRANGE PREMISE INSPECTION
- Open City violation record — CN104025 MAINTAIN WINDOW SASH
- Open City violation record — CN065034 REPAIR WINDOW SILLS
- Open City violation record — CN104055 REPUTTY WINDOW PANES
- Open City violation record — CN061034 FLAKY INTERIOR PAINT
- Open City violation record — CN061014 REPAIR EXTERIOR WALL
- Open City violation record — CN065014 REPAIR LINTELS
- Open City violation record — CN070024 REPAIR PORCH SYSTEM
- Open City violation record — NC2021 PERMIT REQUIRED - CONTRACTOR
- Open City violation record — CN061034 FLAKY INTERIOR PAINT
- Open City violation record — CN104055 REPUTTY WINDOW PANES
- Open City violation record — CN065034 REPAIR WINDOW SILLS
- Open City violation record — CN198019 FILE BLDG REGISTRATION
- Open City violation record — CN104025 MAINTAIN WINDOW SASH
- Open City violation record — CN104035 MAINTAIN WINDOW
- Open City violation record — CN108015 REPAIR SKYLIGHT
- Open City violation record — CN197019 INSTALL SMOKE DETECTORS
- Open heat-related City violation record — PL155027 PROVIDE HOT WATER TO FIXTURES
- Open City violation record — CN065014 REPAIR LINTELS
- Open City violation record — CN077014 REPAIR FENCE
- Open City violation record — NC2011 PLANS & PERMITS REQ - CONTRCTR
- Open City violation record — PL154027 SUPPLY HOT WTR MIN TEMP 120DEG
Recently closed / other violations (sample)
No recent closed violations in the sample.
Around 1315 E 52nd St
- Hyde Park building violations and 311 complaints
- UChicago off-campus housing: Hyde Park renter guide
- No heat in your Chicago apartment? The heat ordinance and what to do
Nearby buildings with open City violation records
Nearby addresses that also have open City violation records in the City of Chicago Building Violations dataset (22u3-xenr), by distance. Open each one for its current free report.
How the winter score is calculated
- Start at 100 (better = higher).
- Minus up to 40 for open heat/boiler-related building violations (12 pts each).
- Minus up to 45 for other open building violations (2 pts each, plus extras above 20 and 100 open).
- Minus up to 20 for rodent-related open violations and 311 rodent complaints (4 pts each).
- Minus up to 15 for recent 311 building complaints (2 pts each).
- Extra −10 if 3+ open heat-related violations.
- Chicago 311 takes no-heat complaints, but the City's public 311 dataset does not publish them as a separate type, so heat here comes from open Department of Buildings heat-related violations (codes/descriptions, e.g. CN132016 HEAT UNIT ADEQUATELY). 311 building complaints are counted separately, not as heat.
- Public records only — not an inspection, appraisal, or legal advice.
Sources: City of Chicago Building Violations (data.cityofchicago.org/d/22u3-xenr); City of Chicago 311 Service Requests (data.cityofchicago.org/d/v6vf-nfxy). Data: City of Chicago (chicago.gov). Data as of November 21, 2026 at 10:09 AM CT.
ScoutMyBuilding summarizes publicly available City data. It is informational only — not legal advice, not a housing inspection, and not a guarantee of current building conditions. City records may be incomplete, delayed, or inaccurate. Always verify with the City of Chicago Department of Buildings, 311, and your own walkthrough before signing a lease.
“This site provides applications using data that has been modified for use from its original source, www.cityofchicago.org, the official website of the City of Chicago. The City of Chicago makes no claims as to the content, accuracy, timeliness, or completeness of any of the data provided at this site. The data provided at this site is subject to change at any time. It is understood that the data provided at this site is being used at one’s own risk.” Required by the City of Chicago Data Terms of Use.