1307 W Addison St
Winter habitability score Some issues on record — read the details
Renter reviews
Firsthand and anonymous. Renter opinions are separate from the city records below.
No renter reviews here yet. If you’ve lived at 1307 W Addison St, yours could be the first.
Do you live here?
One tap helps other renters. The full building record stays right below.
Thanks for looking. The full record is right below.
No problem. The full record is right below.
Thanks, neighbor. Share how it’s really been — one tap on the stars is all it takes.
Thanks. Share how it really was — one tap on the stars is all it takes.
Sure, I’ll share
All open City violation records (12)
2 of 12 open City violation records are from the last 24 months (since November 2024), shown newest first. 10 older ones are collapsed below — still open, still counted.
- Open
CN190019 — ARRANGE PREMISE INSPECTION
ARRANGE FOR INSPECTION / UNABLE TO VERIFY INTERIOR CONDITIONS, DETECTORS AND OR CONCERNS REGARDING TO UNIT 3A WINDOW DAMAGE.
- Open
CN061014 — REPAIR EXTERIOR WALL
1307 W. FRONT OF BUILDING / EXTERIOR WALL - STEP FRACTURED MORTAR AT WEST AND EAST SECTIONS OF 3RD FLOOR.
Show 10 older open City violation records (before November 2024)
- Open
CN062024 — PARAPET
AT NORTH ELEVATION PARAPET, - PARAPET AND WALL BELOW ARE OUT OF PLUMB AND DANGEROUSLY LEANING OVER THE PUBLIC SIDEWALK, MASONRY IS BULGING LEANING OUTWARD WITH THE RISK OF COLLAPSE AT ANY TIME. - SOLDIER COURSE ABOVE 3RD FLOOR WINDOW IS READY TO COLLAPSE. PERMIT IS REQUIRED TO REPAIR PARAPET.
- Open
CN065014 — REPAIR LINTELS
STEEL LINTELS ABOVE 3RD FLOOR WINDOWS ARE SEVERELY RUSTED AND DELAMINATED, LINTELS ARE DEFLECTING WITH GAPS ABOVE, AND PERMIT IS REQUIRED FOR REPAIRS.
- Open
CN060002 — PROVIDE SIDEWALK SHED F/PROTCT
PROVIDE SAFETY CANOPY AT MAIN ENTRANCE 1307 W ADDISON SIDE.
- Open
CN070024 — REPAIR PORCH SYSTEM
SOUTH EAST PORCH-ROTTING STRINGER AT EAST 4X4 AFTER 1ST LEVEL. WEST STRINGER NO BOLTED AT WINDER. 2X8 JOISTS SPAN 11'7"-UNDERSIZED FOR SPAN UNDERSIZED GUARD RAIL AT 3 INSUFFICIENT GUARD RAIL ANCHORS, HAND RAIL ANCHORS. NORTHEAST PORCH WORN AND ROUNDED TREADS. INNER GUARD RAILS NOT 42" TALL. OUTSIDE RAILS IMPROPER HORIZONTAL DESIGN WITH SPACING AS MUCH AS 7 1/2". JOIST HANGERS FOR 2ND FLOOR ARE UNDERSIZED, WOOD RAILS WITH INSUFFICIENT ANCHORS. REAR CENTER PORCH INSUFFICIENT ANCHORING FOR WEST STRINGER TO 1ST FLOOR. IMPROPER HANDRAIL DESIGN WITH GAPS UP TO B" GUARDRAIL AT 3 NOT 42" IN HEIGHT. SOUTHWEST PORCH UNDERSIZED 2X8 JOISTS SPAN 11'5' SEVERAL STRINGERS NOT BOLTED TO OTHER WOOD MEMBERS OBTAIN COMPLETE PLANS AND PERMITS
- Open
CN012022 — 1HR FLR OVER BSMT, 1 OR 2 DU
BASEMENT STORAGE EXPOSED JOISTS AND MISSING DRYWALL/PLASTER LATH- HOLE AT PENETRATIONS.
- Open
CN070034 — REPLACE D&H PORCH
NORTH WEST PORCH SOME RAILS WITH HORIZONTAL DESIGN WITH GAPS AS MUCH AS 11'/2". SOME UNDERSIZED GUARDRAILS. 3RD FLOOR DECK WITH SEVERAL SEVERELY ROTTED JOISTS. ROTTING HEAD BEFORE 3RD FLOOR SOME ROUNDED AND WORN TREADS. DEFLECTING GUARD RAIL AT 3 ROTTING PORCH ROOF DECKING UNDERSIZED JOIST HANGERS FOR 3RD FLOOR. OBTAIN COMPLETE PLANS AND PERMITS.
- Open
CN197087 — CARB MONOX DETECT IN RESID
MISSING CO DETECTOR LAUNDRY ROOM AND HOT WATER BOILER ROOM
- Open
CN070024 — REPAIR PORCH SYSTEM
NORTH EAST PORCH UNDERSIZED GUARD RAILS. SEVERAL MISSING JOIST HANGERS WHERE JOIST CHANGE DIRECTION MISSING JOIST HANGERS AT LEDGER FOR 2. SOUTH-EAST PORCH UNDERSIZED GUARD RAIL AT 3. SEPARATING & LOOSE HAND RAILS TO 2 & 3. REAR SOUTH PORCH LOOSE TREAD AT WINDER TO 3 & ROTTING RISER AT SAME LOCATION-INSUFFICIENT ANCHORING. ROTTING PORCH ROOF DECKING-DETERIORATED, SAGGING SECTIONS UNDER 1-LEDGER NOT BOLTED. NO ACCESS WEST PORCHES-ARRANGE FOR WEST PORCH INSPECTION & OBTAIN PERMIT FOR PORCH WORK AS CITED. (PLANS NOT REQUIRED-NOT INCLUDING WEST PORCHES WHICH HAVE UNKNOWN STAIRS.)
- Open
NC2021 — PERMIT REQUIRED - CONTRACTOR
PERMIT FOR REAPIRS.
- Open
CN070034 — REPLACE D&H PORCH
REAR PORCH SYSTEMS STRINGERS NOT BOLTED TO EXTERIOR WALLS 1315 6X6 COLUMN NOT ENCASED AND RESTING ON BROKEN CONCRETE 1 TO 3 BROKEN AND ROTTED HAND RAILING D&H JOIST NOT PROPERLY NOTCHED INTO EXTERIOR WALL. GRADE TO 1ST VOLTED 4X4 POST 1311-17 2ND TO 3RD LARGE GAP BETWEEN TOP AND BOTTOM HAND RAILING MORE THAN 2 FEET. EXCESSIVE SCABBING ON 4X4 POST.
About these City violation records
From the City of Chicago Building Violations dataset description: “…informational only and does not necessarily reflect the current condition of the building or property. The dataset contains cases where a respondent has been found to be liable as well as cases where the respondent has been found to be not liable.”
311 complaints (24 months)
No matching 311 complaints in the last 24 months.
Timeline
- Open City violation record — CN061014 REPAIR EXTERIOR WALL
- Open City violation record — CN190019 ARRANGE PREMISE INSPECTION
- Open City violation record — CN060002 PROVIDE SIDEWALK SHED F/PROTCT
- Open City violation record — CN065014 REPAIR LINTELS
- Open City violation record — CN062024 PARAPET
- Open City violation record — CN197087 CARB MONOX DETECT IN RESID
- Open City violation record — CN070034 REPLACE D&H PORCH
- Open City violation record — CN012022 1HR FLR OVER BSMT, 1 OR 2 DU
- Open City violation record — CN070024 REPAIR PORCH SYSTEM
- Open City violation record — CN070024 REPAIR PORCH SYSTEM
- Open City violation record — CN070034 REPLACE D&H PORCH
- Open City violation record — NC2021 PERMIT REQUIRED - CONTRACTOR
Recently closed / other violations (sample)
- Closed / other
CN061014 REPAIR EXTERIOR WALL
- Closed / other
CN065034 REPAIR WINDOW SILLS
- Closed / other
CN061014 REPAIR EXTERIOR WALL
Around 1307 W Addison St
- Lake View building violations and 311 complaints
- DePaul off-campus housing: Lakeview and Lincoln Park renter guide
Nearby buildings with open City violation records
Nearby addresses that also have open City violation records in the City of Chicago Building Violations dataset (22u3-xenr), by distance. Open each one for its current free report.
How the winter score is calculated
- Start at 100 (better = higher).
- Minus up to 40 for open heat/boiler-related building violations (12 pts each).
- Minus up to 45 for other open building violations (2 pts each, plus extras above 20 and 100 open).
- Minus up to 20 for rodent-related open violations and 311 rodent complaints (4 pts each).
- Minus up to 15 for recent 311 building complaints (2 pts each).
- Extra −10 if 3+ open heat-related violations.
- Chicago 311 takes no-heat complaints, but the City's public 311 dataset does not publish them as a separate type, so heat here comes from open Department of Buildings heat-related violations (codes/descriptions, e.g. CN132016 HEAT UNIT ADEQUATELY). 311 building complaints are counted separately, not as heat.
- Public records only — not an inspection, appraisal, or legal advice.
Sources: City of Chicago Building Violations (data.cityofchicago.org/d/22u3-xenr); City of Chicago 311 Service Requests (data.cityofchicago.org/d/v6vf-nfxy). Data: City of Chicago (chicago.gov). Data as of November 21, 2026 at 10:09 AM CT.
ScoutMyBuilding summarizes publicly available City data. It is informational only — not legal advice, not a housing inspection, and not a guarantee of current building conditions. City records may be incomplete, delayed, or inaccurate. Always verify with the City of Chicago Department of Buildings, 311, and your own walkthrough before signing a lease.
“This site provides applications using data that has been modified for use from its original source, www.cityofchicago.org, the official website of the City of Chicago. The City of Chicago makes no claims as to the content, accuracy, timeliness, or completeness of any of the data provided at this site. The data provided at this site is subject to change at any time. It is understood that the data provided at this site is being used at one’s own risk.” Required by the City of Chicago Data Terms of Use.