Free building report

128 N Hoyne Ave

Winter habitability score Some issues on record — read the details

Download a PDF of this report

Renter reviews

Firsthand and anonymous. Renter opinions are separate from the city records below.

No renter reviews here yet. If you’ve lived at 128 N Hoyne Ave, yours could be the first.

A Chicago three-flat

Do you live here?

One tap helps other renters. The full building record stays right below.

Sure, I’ll share
How’s it been living here? Required

Tap a star — 1 is rough, 5 is great.

Add more detail (optional — heat, pests, repairs, noise, management)

Tap 1 to 5 for any you want. 1 is rough, 5 is great. Skip the rest.

Heat Warm enough when it counts?
Pests Have pests been a problem?
Maintenance responsiveness When something broke, how fast did it get fixed?
Noise How noisy was it, day to day?
Management How they treated you and answered you
Would you rent here again?

Your own experience only — no fake or paid reviews. Shown anonymously after you confirm and a person approves it. Review policy · Terms

11Open City violation records
0Open heat-related City records
0311 rodent (24 mo)
0311 building (24 mo)

What rat complaints mean →

All open City violation records (11)

No open City violation records dated in the last 24 months (since November 2024). The newest open one is from August 8, 2016. All 11 are collapsed below — still open, still counted.

Show 11 older open City violation records (before November 2024)
  • Open

    CN076044 — REPAIR DOWNSPOUT

    REAR OF BUILDING/BETWEEN TWO REAR PORCHES ¿ MISSING DOWNSPOUT SECTION FROM ROOF GUTTER TO 1ST FLOOR.

  • Open

    CN070034 — REPLACE D&H PORCH

    WEST ELEVATION - SOUTH 2-STORY REAR WOOD PORCH ¿ SOME 4X4 AND 6X6 COLUMNS ERECTED ON CONCRETE SLAB, WITHOUT BASES AND WITH FOUNDATION STATUS UNKNOWN, OTHERS ¿ ON BASES, WITH CRUMBLING CONCRETE. NORTHWEST 6X6 COLUMN ¿ OUT OF PLUMB AND BOWED. UNDERSIZED 2X10 SECOND FLOOR DECK JOISTS SPAN 11 FEET. UPPER AND LOWER ENDS OF STRINGERS INADEQUATELY SUPPORTED. LANDING ¿ UNSTABLE, PULLING, AND SWAYING. RAILING SECTIONS LOOSE AND PULLING. PICKETS ¿ CRACKED, LOOSE, BROKEN, AND SOME MISSING. LARGE SECTION OF 2ND FLOOR DECK NEAR 128 N./REAR EXIT DOOR - BURNED OUT AND HAS MISSING DECK SECTION AND MISSING RAILING SECTIONS (FALL HAZARD), BURNED OUT AND MISSING SECTIONS OF RIM AND DECK JOISTS. REMAINING DECK BOARDS AND TREADS ¿ WORN OUT, CRACKED, WARPED, AND LOOSE. NORTH 2-STORY REAR WOOD PORCH ¿ SOME 6X6 COLUMNS ERECTED ON BASES, WITH CRUMBLING CONCRETE. TRIPLED RIM JOISTS INADEQUATELY SUPPORTED AT COLUMNS. SOME RIM JOISTS DO NOT REST ON SEAT ANGLES HAVING GAPS BETWEEN THEM. SOME SEAT ANGLES HAVE LOOSE NUTS ON FASTENING BOLTS, AND MOVE. UPPER AND LOWER ENDS OF STRINGERS INADEQUATELY SUPPORTED. LANDING ¿ UNSTABLE, PULLING, AND SWAYING. RAILING SECTIONS LOOSE AND PULLING. PICKETS ¿ CRACKED, LOOSE, BROKEN, AND SOME MISSING. DECK BOARDS AND TREADS ¿ WORN OUT, CRACKED, WARPED, AND LOOSE. PLANS AND PERMIT REQUIRED TO REPLACE BOTH DANGEROUS AND HAZARDOUS REAR PORCHES.

  • Rodent-related

    CN136016 — ROACHES

    APT. 130B - KITCHEN ROACH INFESTATION.

  • Open

    CN070014 — REPAIR EXTERIOR STAIR

    EAST ELEVATIOIN, 130B, 132B, 134B AND 136B STAIRS - BRICK AND BLOCK CRACKED, SPALLED AND FALLING APART WITH A LARGE FRACTURE AT NORTH AND SOUTH SIDES OF STAIRS. ALL STAIRS WASHED OUT MORTAR.

  • Open

    CN065034 — REPAIR WINDOW SILLS

    EAST ELEVATION, 3RD FLOOR WINDOWS - OPEN SILL JOINTS.

  • Open

    CN131026 — REPAIR SCREENS

    EAST ELEVATION, MULTIPLE FLOORS - RIPPED AND BROKEN WINDOW SCREENS.

  • Open

    CN073014 — REPAIR EXTERIOR DOOR

    EAST ELEVATION, APT. 136B - MISSING GLASS PANNEL IN SCREEN DOOR.

  • Open

    CN101015 — REPAIR INTERIOR WALLS/CEILING

    APT 130B - FOYER ENTRY CEILING LEAKING CEILING WATER DAMAGED.

  • Open

    CN104045 — WINDOW OPEN EASILY, STAY OPEN

    APT. 130B - MULTIPLE WINDOW S VERY DIFFICUT TO OPEN.

  • Open

    CN104015 — REPLCE WINDOW PANES, PLEXGLAS

    WEST ELEVATION, 2ND FLOOR - BROKEN WINDOW.

  • Open

    CN065014 — REPAIR LINTELS

    EAST ELEVATION, 3RD FLOOR WINDOW LINTELS - MINOR RUSTING.

About these City violation records

From the City of Chicago Building Violations dataset description: “…informational only and does not necessarily reflect the current condition of the building or property. The dataset contains cases where a respondent has been found to be liable as well as cases where the respondent has been found to be not liable.”

↑ Back to renter reviews

311 complaints (24 months)

No matching 311 complaints in the last 24 months.

Timeline

  1. Open City violation record — CN065014 REPAIR LINTELS
  2. Open City violation record — CN104015 REPLCE WINDOW PANES, PLEXGLAS
  3. Open City violation record — CN104045 WINDOW OPEN EASILY, STAY OPEN
  4. Open City violation record — CN101015 REPAIR INTERIOR WALLS/CEILING
  5. Open City violation record — CN073014 REPAIR EXTERIOR DOOR
  6. Open City violation record — CN131026 REPAIR SCREENS
  7. Open City violation record — CN065034 REPAIR WINDOW SILLS
  8. Open City violation record — CN070014 REPAIR EXTERIOR STAIR
  9. Open City violation record — CN136016 ROACHES
  10. Open City violation record — CN070034 REPLACE D&H PORCH
  11. Open City violation record — CN076044 REPAIR DOWNSPOUT

Recently closed / other violations (sample)

No recent closed violations in the sample.

Around 128 N Hoyne Ave

Nearby buildings with open City violation records

Nearby addresses that also have open City violation records in the City of Chicago Building Violations dataset (22u3-xenr), by distance. Open each one for its current free report.

How the winter score is calculated
  1. Start at 100 (better = higher).
  2. Minus up to 40 for open heat/boiler-related building violations (12 pts each).
  3. Minus up to 45 for other open building violations (2 pts each, plus extras above 20 and 100 open).
  4. Minus up to 20 for rodent-related open violations and 311 rodent complaints (4 pts each).
  5. Minus up to 15 for recent 311 building complaints (2 pts each).
  6. Extra −10 if 3+ open heat-related violations.
  7. Chicago 311 takes no-heat complaints, but the City's public 311 dataset does not publish them as a separate type, so heat here comes from open Department of Buildings heat-related violations (codes/descriptions, e.g. CN132016 HEAT UNIT ADEQUATELY). 311 building complaints are counted separately, not as heat.
  8. Public records only — not an inspection, appraisal, or legal advice.

Sources: City of Chicago Building Violations (data.cityofchicago.org/d/22u3-xenr); City of Chicago 311 Service Requests (data.cityofchicago.org/d/v6vf-nfxy). Data: City of Chicago (chicago.gov). Data as of November 21, 2026 at 9:35 AM CT.

ScoutMyBuilding summarizes publicly available City data. It is informational only — not legal advice, not a housing inspection, and not a guarantee of current building conditions. City records may be incomplete, delayed, or inaccurate. Always verify with the City of Chicago Department of Buildings, 311, and your own walkthrough before signing a lease.

“This site provides applications using data that has been modified for use from its original source, www.cityofchicago.org, the official website of the City of Chicago. The City of Chicago makes no claims as to the content, accuracy, timeliness, or completeness of any of the data provided at this site. The data provided at this site is subject to change at any time. It is understood that the data provided at this site is being used at one’s own risk.” Required by the City of Chicago Data Terms of Use.

Check another address