Free building report

1235 W North Shore Ave

Winter habitability score Multiple habitability signals in public records

Download a PDF of this report

Renter reviews

Firsthand and anonymous. Renter opinions are separate from the city records below.

No renter reviews here yet. If you’ve lived at 1235 W North Shore Ave, yours could be the first.

A Chicago three-flat

Do you live here?

One tap helps other renters. The full building record stays right below.

Sure, I’ll share
How’s it been living here? Required

Tap a star — 1 is rough, 5 is great.

Add more detail (optional — heat, pests, repairs, noise, management)

Tap 1 to 5 for any you want. 1 is rough, 5 is great. Skip the rest.

Heat Warm enough when it counts?
Pests Have pests been a problem?
Maintenance responsiveness When something broke, how fast did it get fixed?
Noise How noisy was it, day to day?
Management How they treated you and answered you
Would you rent here again?

Your own experience only — no fake or paid reviews. Shown anonymously after you confirm and a person approves it. Review policy · Terms

41Open City violation records
0Open heat-related City records
0311 rodent (24 mo)
0311 building (24 mo)

What rat complaints mean →

All open City violation records (41)

No open City violation records dated in the last 24 months (since November 2024). The newest open one is from August 14, 2024. All 41 are collapsed below — still open, still counted.

Show 41 older open City violation records (before November 2024)
  • Open

    CN061014 — REPAIR EXTERIOR WALL

    REAR ELEVATION /EXTERIOR WALL - CRACKED, CRUMBLING PARGE COAT NEAR GRADE; SPALLED BRICK SECTIONS WITH WASHED OUT MORTAR JOINTS THROUGHOUT.

  • Open

    CN190029 — ARRANGE FOR REINSPECTION REGAR

    INTERIOR OF BUILDING - NO RESPONSE. UNVERIFIED DETECTORS AND CONDITIONS. UNABLE TO INSPECT INTERIOR STAIRWAY SYSTEMS. UNABLE TO CONFIRM INTERIOR COMPLAINT OF RODENT INFESTATION.

  • Open

    CN103015 — REPAIR FLOOR

    1237 W. AND 1239 W. ENTRY FOYERS , LOOSE AND MISSING FLOOR TILE SECTIONS , EXPOSED , ROUGH CONCRETE .

  • Open

    CN190019 — ARRANGE PREMISE INSPECTION

    INTERIOR OF BUILDING - NO RESPONSE , UNVERIFIED CONDITIONS , OCCUPANCY AND DETECTORS . NO ENTRY FOR 2014 ANNUAL INSPECTION AND TO VIEW PREVIOUS VIOLATIONS .

  • Open

    CN196029 — POST OWNER/MANAGERS NAME/#

    BUILDING - POSTED OWNER'S I.D. SIGN INCOMPLETE INFORMATION . MISSING COMPLETE MAILING ADDRESS AND COMPLETE PHONE NUMBER .

  • Open

    CN106015 — REPAIR INTERIOR STAIR SYSTEM

    SOUTHWEST BASEMENT LAUNDRY ROOM - CONCRETE FRONT AND REAR ENTRY STAIRS MISSING HANDRAILS AND GUARDRAILS .

  • Open

    CN138066 — DEMO DEBRIS

    SOUTHWEST BASEMENT LAUNDRY ROOM - BROKEN , DILAPIDATED AND PILED WOOD TENANT STORAGE SHEDS .

  • Open

    CN012022 — 1HR FLR OVER BSMT, 1 OR 2 DU

    SOUTHWEST BASEMENT LAUNDRY ROOM - CEILING BROKEN AND LOOSE PLASTER , HOLES WITH EXPOSED WOOD FLOOR FRAMING .

  • Open

    CN105085 — PROVIDE DEADLOCK FOR ENTRANCE

    ALL NORTH FRONT ENTRY DOORS , MISSING DEADBOLT LOCKS , FRONT ENTRY FOYERS NOT SECURE .

  • Open

    CN065024 — MAINTAIN PROJECTIONS

    NORTH ELEVATION , WINDOW IRON BALCONETTE RAILS AT FIRST THROUGH THIRD FLOOR RUSTED, DETERIORATED , WITH FLAKING PAINT

  • Open

    CN061014 — REPAIR EXTERIOR WALL

    NORTH ELEVATION FROM GRADE TO FIRST FLOOR , OPEN MORTAR FRACTURES BETWEEN BRICK AND STONES , OPEN MORTAR JOINTS . NORTH AND SOUTH ELEVATIONS , LOOSE AND TANGLED PHONE AND CABLE LINES . BROKEN AND LOOSE RACEWAYS AND OPEN CABINETS .

  • Open

    CN067014 — REPAIR ROOF

    NORTH ELEVATION AND NORTH CENTER AREAWAY , ROOF SECTIONS WITH CLAY TILES AND SHINGLES , RAFTER TAILS AND WOOD ROOF DECKING ROTTED , DETERIORATED WITH FLAKING PAINT .

  • Open

    CN062024 — PARAPET

    EAST AT NORTH , PARAPET WALL SPALLED BRICKS AND OPEN MORTAR JOINTS .

  • Open

    CN073024 — REPAIR EXTERIOR DOOR FRAME

    NORTHEAST AND NORTHWEST AREAWAYS , ENTRY DOOR FRAMES , ROTTED WITH FALKING PAINT .

  • Open

    CN069034 — REPAIR AREAWAY WALL

    NORTHEAST AREAWAY CEILING , HOLES WITH BROKEN PLASTER .

  • Open

    CN074024 — PROVIDE GUARD RAIL 42 IN HIGH

    NORTH AT CENTER AREAWAY , AT FIRST THROUGH THIRD FLOORS . IRON BALCONY GUARDRAILS FOR PATIO DOORS , UNDERSIZED ( APPROXIMATELY 30 INCHES TALL ) , RUSTED , DETERIORATED WITH FLAKING PAINT . FALL HAZARD TO TENANTS AND OCCUPANTS . PERMIT REQUIRED FOR GUARDRAIL REPAIRS .

  • Open

    CN104015 — REPLCE WINDOW PANES, PLEXGLAS

    1237 W. -NORTH CENTER AREAWAY , BROKEN WINDOW GLASS PANE .

  • Open

    CN104025 — MAINTAIN WINDOW SASH

    WOOD WINDOW SASHES AND WOOD WINDOW SASHES BEHIND STORM WINDOWS , ROTTED WITH FLAKING PAINT AND PUTTY .

  • Open

    CN104035 — MAINTAIN WINDOW

    WOOD WINDOW FRAMES , ROTTED WITH FLAKING PAINT AND PUTTY .

  • Open

    CN065014 — REPAIR LINTELS

    NORTH AREAWAY , WINDOW LINTELS RUSTED , DETERIORATED , WAVY METAL , FLAKING PAINT , OPEN SAG GAP FILLED WITH MORTAR . PERMITS REQUIRED FOR LINTEL REPAIRS .

  • Open

    CN073054 — REPAIR EXTERIOR DOOR, RESET

    1235 W. AND 1241 W. FRONT ENTRY DOORS RUB ON FRAMES , SAGGING AND WILL NOT CLOSE .

  • Open

    CN073014 — REPAIR EXTERIOR DOOR

    FRONT ENTRY DOORS AND FRAMES WORN AND WEATHERED FINISH , FRAMES ROTTED AT BASE .

  • Open

    CN076024 — REPAIR GUTTER & DOWNSPOUT

    SOUTHEAST AND SOUTHWEST PORCH ROOF GUTTERS AND DOWNSPOUTS , RUSTED , LEAKING WITH FLAKING PAINT .

  • Open

    CN190019 — ARRANGE PREMISE INSPECTION

    INTERIOR OF BUILDING - NO RESPONSE, UNVERIFIED DETECTORS AND CONDITIONS. NO ENTRY TO 1239 APARTMENT 3F TO VERIFY COMPLAINT OF BEDBUGS.

  • Open

    CN061014 — REPAIR EXTERIOR WALL

    SOUTH ELEVATION VARIOUS LOCATIONS THROUGHOUT - SPALLING BRICKS AND WASHED OUT MORTAR.

  • Open

    CN198019 — FILE BLDG REGISTRATION

    BUILDING - NOT REGISTERED FOR 2011 AND 2012.

  • Open

    CN065014 — REPAIR LINTELS

    NORTH ELEVATION,FRONT COURTYARD,LINTALS RUSTY AT VARIOUS LOCATIONS.

  • Open

    CN076024 — REPAIR GUTTER & DOWNSPOUT

    EAST ELEVATION AT REAR,RUSTY GUTTERS WITH HOLES AND DOWNSPOUT IS LOOSE AND HANGING.

  • Open

    CN061014 — REPAIR EXTERIOR WALL

    EAST AND WEST ELEVATION WASHED OUT MORTAR AT GRADE,SOUTH ELEVATION GRADE TO 3RD WASHED OUT MORTAR.

  • Open

    CN190029 — ARRANGE FOR REINSPECTION REGAR

    UNABLE TO VERIFY DETECTORS,CONDITION,AND OCCUPANCY BSMT,1ST,2ND AND 3RD,NO ENTRY REAR PORCH

  • Open

    CN061034 — FLAKY INTERIOR PAINT

    ALL LOCATION LINTELS RUSTED AND PEELING PAINT

  • Open

    CN076024 — REPAIR GUTTER & DOWNSPOUT

    EAST AND WEST ELEVATION GUTTERS RUSTED WITH HOLES,DOWNSPOUT MISSING

  • Open

    CN076024 — REPAIR GUTTER & DOWNSPOUT

    EAST AND WEST ELEVATION GUTTERS RUSTED WITH HOLES,DOWNSPOUT MISSING

  • Open

    CN197019 — INSTALL SMOKE DETECTORS

    1239 APT 2F AND 3F MISSING SMOKE DETECTORS.

  • Open

    CN104035 — MAINTAIN WINDOW

    1239 WEST ELEVATION WINDOWS FRAME ROTTED.

  • Open

    CN140036 — PIGEONS-UNSANITARY HOUSING

    REAR NORTH EXTERIOR STAIRWAY - PIGEONS HOUSE.

  • Open

    CN070024 — REPAIR PORCH SYSTEM

    REAR WEST PORCH SYSTEM - STRINGERS NOT BOLTED TO WALL AND COLUMNS. GUARDRAIL HEIGHT LESS THAN 42". SIMILAR DEFECT EXIT IN REAR NORTH PORCH SYSTEM. COLUMN ON 3RD FLOOR LEVEL IS LOOSE STAIR RISERS AND TREADS UNEVEN. COLUMN BASE RESTING ON SMALL PIECES OF BRICK. ALL MEMBERS OF THE PORCH SYSTEMS 1239-1245 ARE SEVERELY ROTTED.

  • Open

    CN190019 — ARRANGE PREMISE INSPECTION

    NO ENTRY TO 1235-37 STAIRWAY SYSTEM TO CONDUCT INSPECTIONS.

  • Open

    NC2011 — PLANS & PERMITS REQ - CONTRCTR

    PROVIDE PLANS AND PERMIT FOR ALL PORCH REPAIRS.

  • Open

    CN196029 — POST OWNER/MANAGERS NAME/#

    BUILDING NOT REG 2005 (L.S.F)

  • Open

    CN074014 — SERVICE WALK, PASSAGE, AREAWAY

    1239 REAR SERVICE WALKWAY BROKEN.

About these City violation records

From the City of Chicago Building Violations dataset description: “…informational only and does not necessarily reflect the current condition of the building or property. The dataset contains cases where a respondent has been found to be liable as well as cases where the respondent has been found to be not liable.”

↑ Back to renter reviews

311 complaints (24 months)

No matching 311 complaints in the last 24 months.

Timeline

  1. Open City violation record — CN190029 ARRANGE FOR REINSPECTION REGAR
  2. Open City violation record — CN061014 REPAIR EXTERIOR WALL
  3. Open City violation record — CN076024 REPAIR GUTTER & DOWNSPOUT
  4. Open City violation record — CN073014 REPAIR EXTERIOR DOOR
  5. Open City violation record — CN073054 REPAIR EXTERIOR DOOR, RESET
  6. Open City violation record — CN065014 REPAIR LINTELS
  7. Open City violation record — CN104035 MAINTAIN WINDOW
  8. Open City violation record — CN104025 MAINTAIN WINDOW SASH
  9. Open City violation record — CN104015 REPLCE WINDOW PANES, PLEXGLAS
  10. Open City violation record — CN074024 PROVIDE GUARD RAIL 42 IN HIGH
  11. Open City violation record — CN069034 REPAIR AREAWAY WALL
  12. Open City violation record — CN073024 REPAIR EXTERIOR DOOR FRAME
  13. Open City violation record — CN062024 PARAPET
  14. Open City violation record — CN067014 REPAIR ROOF
  15. Open City violation record — CN061014 REPAIR EXTERIOR WALL
  16. Open City violation record — CN065024 MAINTAIN PROJECTIONS
  17. Open City violation record — CN105085 PROVIDE DEADLOCK FOR ENTRANCE
  18. Open City violation record — CN012022 1HR FLR OVER BSMT, 1 OR 2 DU
  19. Open City violation record — CN138066 DEMO DEBRIS
  20. Open City violation record — CN106015 REPAIR INTERIOR STAIR SYSTEM
  21. Open City violation record — CN196029 POST OWNER/MANAGERS NAME/#
  22. Open City violation record — CN190019 ARRANGE PREMISE INSPECTION
  23. Open City violation record — CN103015 REPAIR FLOOR
  24. Open City violation record — CN198019 FILE BLDG REGISTRATION
  25. Open City violation record — CN061014 REPAIR EXTERIOR WALL
  26. Open City violation record — CN190019 ARRANGE PREMISE INSPECTION
  27. Open City violation record — CN061014 REPAIR EXTERIOR WALL
  28. Open City violation record — CN076024 REPAIR GUTTER & DOWNSPOUT
  29. Open City violation record — CN065014 REPAIR LINTELS
  30. Open City violation record — CN076024 REPAIR GUTTER & DOWNSPOUT
  31. Open City violation record — CN076024 REPAIR GUTTER & DOWNSPOUT
  32. Open City violation record — CN061034 FLAKY INTERIOR PAINT
  33. Open City violation record — CN190029 ARRANGE FOR REINSPECTION REGAR
  34. Open City violation record — CN074014 SERVICE WALK, PASSAGE, AREAWAY
  35. Open City violation record — CN196029 POST OWNER/MANAGERS NAME/#
  36. Open City violation record — NC2011 PLANS & PERMITS REQ - CONTRCTR
  37. Open City violation record — CN190019 ARRANGE PREMISE INSPECTION
  38. Open City violation record — CN070024 REPAIR PORCH SYSTEM
  39. Open City violation record — CN140036 PIGEONS-UNSANITARY HOUSING
  40. Open City violation record — CN104035 MAINTAIN WINDOW

Recently closed / other violations (sample)

  • Closed / other

    CN061034 FLAKY INTERIOR PAINT

  • Closed / other

    CN073014 REPAIR EXTERIOR DOOR

  • Closed / other

    CN140046 PIGEONS-NESTING

  • Closed / other

    CN106015 REPAIR INTERIOR STAIR SYSTEM

Around 1235 W North Shore Ave

Nearby buildings with open City violation records

Nearby addresses that also have open City violation records in the City of Chicago Building Violations dataset (22u3-xenr), by distance. Open each one for its current free report.

How the winter score is calculated
  1. Start at 100 (better = higher).
  2. Minus up to 40 for open heat/boiler-related building violations (12 pts each).
  3. Minus up to 45 for other open building violations (2 pts each, plus extras above 20 and 100 open).
  4. Minus up to 20 for rodent-related open violations and 311 rodent complaints (4 pts each).
  5. Minus up to 15 for recent 311 building complaints (2 pts each).
  6. Extra −10 if 3+ open heat-related violations.
  7. Chicago 311 takes no-heat complaints, but the City's public 311 dataset does not publish them as a separate type, so heat here comes from open Department of Buildings heat-related violations (codes/descriptions, e.g. CN132016 HEAT UNIT ADEQUATELY). 311 building complaints are counted separately, not as heat.
  8. Public records only — not an inspection, appraisal, or legal advice.

Sources: City of Chicago Building Violations (data.cityofchicago.org/d/22u3-xenr); City of Chicago 311 Service Requests (data.cityofchicago.org/d/v6vf-nfxy). Data: City of Chicago (chicago.gov). Data as of November 21, 2026 at 9:39 AM CT.

ScoutMyBuilding summarizes publicly available City data. It is informational only — not legal advice, not a housing inspection, and not a guarantee of current building conditions. City records may be incomplete, delayed, or inaccurate. Always verify with the City of Chicago Department of Buildings, 311, and your own walkthrough before signing a lease.

“This site provides applications using data that has been modified for use from its original source, www.cityofchicago.org, the official website of the City of Chicago. The City of Chicago makes no claims as to the content, accuracy, timeliness, or completeness of any of the data provided at this site. The data provided at this site is subject to change at any time. It is understood that the data provided at this site is being used at one’s own risk.” Required by the City of Chicago Data Terms of Use.

Check another address

Help: hello@scoutmybuilding.com