Free building report
1220 E 54th St
Winter habitability score Multiple habitability signals in public records
Renter reviews
Firsthand and anonymous. Renter opinions are separate from the city records below.
No renter reviews here yet. If you’ve lived at 1220 E 54th St, yours could be the first.
Do you live here?
One tap helps other renters. The full building record stays right below.
Thanks for looking. The full record is right below.
No problem. The full record is right below.
Thanks, neighbor. Share how it’s really been — one tap on the stars is all it takes.
Thanks. Share how it really was — one tap on the stars is all it takes.
Sure, I’ll share
All open City violation records (16)
7 of 16 open City violation records are from the last 24 months (since November 2024), shown newest first. 9 older ones are collapsed below — still open, still counted.
- Open
CN132046 — SAFE WORKING CONDITIONS
1220 APT 1 / RADIATOR NEEDS SERVICING; WATER AND STEAM SPRAYING ALL OVER WOOD WALLS CAUSING THEM TO PEEL IN BEDROOM. 14X-8-804.
- Open
CN196029 — POST OWNER/MANAGERS NAME/#
BUILDING / MANAGEMENT INFORMATION NOT POSTED.
- Open
CN066034 — REPAIR BALCONY
SOUTH ELEVATION / BALCONY CEILINGS - CRACKING, AND CRUMBLING CONCRETE.
- Open
CN190019 — ARRANGE PREMISE INSPECTION
INTERIOR OF BUILDING - NO RESPONSE. UNVERIFIED DETECTORS AND CONDITIONS. UNABLE TO INSPECT INTERIOR STAIRWAY SYSTEMS. UNABLE TO CONFIRM INTERIOR COMPLAINT OF GAS LEAK AND BASEMENT OCCUPANCY.
- Open
CN138106 — STOP/REMOVE NUISANCE
NORTH ELEVATION / 3 STORY WOOD PORCH SYSTEM - FURNITURE, MATTRESS, AND OTHER HOUSEHOLD ITEMS SCATTERED THROUGHOUT.
- Open
CN014012 — NO CLOSET/STORAGE UNDER STAIR
NORTH ELEVATION / FURITURE STORED UNDER PORCH SYSTEM BLOCKING BASEMENT DOORS.
- Open
CN077014 — REPAIR FENCE
WEST ELEVATION / FENCE - BROKEN, AND LOOSE TOP RAIL, MISSING SECTION AND GATE.
Show 9 older open City violation records (before November 2024)
- Open
CN106015 — REPAIR INTERIOR STAIR SYSTEM
1ST FLOOR TO BASEMENT / INTERIOR STAIRWAY HAS BEEN REMOVED AND STEEL SPIRAL STAIRWAY HAS BEEN INSTALLED/ STAIRS ARE NARROW AND HARD TO TRAVEL TO GET TO LAUNDRY ROOM. PLANS AND PERMIT REQUIRED FOR ALL INTERIOR STAIR REPAIRS. SUBJECT TO FIELD INSPECTION AND APPROVAL.
- Open
CN104035 — MAINTAIN WINDOW
BUILDING / WINDOW WOOD FRAMES - FAKING PAINT.
- Open
CN064014 — REPAIR CORNICE
SOUTH ELEVATION / CORNICE - WASHED OUT MORTAR. TOP OF CORNICE HAS TREE BRANCHES GROWING.
- Open
CN070024 — REPAIR PORCH SYSTEM
NORTH ELEVATION / 3 STORRY WOOD PORCH / COLUMNS ERECTED ON CONCRETE BLOCKS. FOUNDATION STATUS - UNKNOWN. COLUMN HALF LAP JOINTS - 12 INCHES WITH ONLY 2 BOLTS. COLUMN TO BEAM CONNECTIONS - SPPERATING AND FASTENED WITH LIGHT GUAGE METAL BRACKETS. STAIR LANDING - CANTILEVERED PASSED COLUMNS UP TO 32 INCHES AND HAVE 4X4 ANGLED AT 45* AND NOTCHED INTO COLUMNS. DECK JOISTS - FASTENED WITH NAILS ONLY. ALL RAILINGS - FASTENED WITH NAILS ONLY. PLANS AND PERMIT REQUIRED TO REPLACE REAR 3 STORY WOOD PORCH.
- Open
CN197019 — INSTALL SMOKE DETECTORS
BASEMENT AT BOILER AND LAUNDRY ROOMS AND 1220 APT 3 / SMOKE DETECTORS - MISSING.
- Open
CN197079 — REPAIR/REPLACE SMOKE DETECTORS
1222 APT 1 SMOKE DETECTOR - OUT OF SERVICE. FRONT STAIRWAY SMOKE DETECTOR - OUT OF DATE.
- Open
CN197087 — CARB MONOX DETECT IN RESID
BASEMENT AND 1222 APT 1 / CARBON MONOXIDE DETECTORS - MISSING.
- Open
CN066034 — REPAIR BALCONY
SOUTH ELEVATION / BALCONIES - SPALLED AND LOOSE CONCRETE WITH EXPOSED RUSTED REBAR. PERMIT REQUIRED FOR ALL BALCONY REPAIRS. SUBJECT TO FIELD INSPECTION AND APROVAL.
- Open
CN138106 — STOP/REMOVE NUISANCE
REAR YARD AND AT REAR PORCH - STORING APPLIANCES, FURNATURES AND HOUSEHOLD BELONGINGS THROUGHOUT.
About these City violation records
From the City of Chicago Building Violations dataset description: “…informational only and does not necessarily reflect the current condition of the building or property. The dataset contains cases where a respondent has been found to be liable as well as cases where the respondent has been found to be not liable.”
311 complaints (24 months)
- building
Building Violation
- rodent
Rodent Baiting/Rat Complaint
- building
Building Violation
- building
Building Violation
- building
Building Violation
Timeline
- 311 rodent — Rodent Baiting/Rat Complaint
- 311 building — Building Violation
- 311 building — Building Violation
- Open City violation record — CN132046 SAFE WORKING CONDITIONS
- 311 building — Building Violation
- 311 building — Building Violation
- Open City violation record — CN077014 REPAIR FENCE
- Open City violation record — CN014012 NO CLOSET/STORAGE UNDER STAIR
- Open City violation record — CN138106 STOP/REMOVE NUISANCE
- Open City violation record — CN190019 ARRANGE PREMISE INSPECTION
- Open City violation record — CN066034 REPAIR BALCONY
- Open City violation record — CN196029 POST OWNER/MANAGERS NAME/#
- Open City violation record — CN138106 STOP/REMOVE NUISANCE
- Open City violation record — CN066034 REPAIR BALCONY
- Open City violation record — CN197087 CARB MONOX DETECT IN RESID
- Open City violation record — CN197079 REPAIR/REPLACE SMOKE DETECTORS
- Open City violation record — CN197019 INSTALL SMOKE DETECTORS
- Open City violation record — CN070024 REPAIR PORCH SYSTEM
- Open City violation record — CN064014 REPAIR CORNICE
- Open City violation record — CN104035 MAINTAIN WINDOW
- Open City violation record — CN106015 REPAIR INTERIOR STAIR SYSTEM
Recently closed / other violations (sample)
No recent closed violations in the sample.
Around 1220 E 54th St
Nearby buildings with open City violation records
Nearby addresses that also have open City violation records in the City of Chicago Building Violations dataset (22u3-xenr), by distance. Open each one for its current free report.
How the winter score is calculated
- Start at 100 (better = higher).
- Minus up to 40 for open heat/boiler-related building violations (12 pts each).
- Minus up to 45 for other open building violations (2 pts each, plus extras above 20 and 100 open).
- Minus up to 20 for rodent-related open violations and 311 rodent complaints (4 pts each).
- Minus up to 15 for recent 311 building complaints (2 pts each).
- Extra −10 if 3+ open heat-related violations.
- Chicago 311 takes no-heat complaints, but the City's public 311 dataset does not publish them as a separate type, so heat here comes from open Department of Buildings heat-related violations (codes/descriptions, e.g. CN132016 HEAT UNIT ADEQUATELY). 311 building complaints are counted separately, not as heat.
- Public records only — not an inspection, appraisal, or legal advice.
Sources: City of Chicago Building Violations (data.cityofchicago.org/d/22u3-xenr); City of Chicago 311 Service Requests (data.cityofchicago.org/d/v6vf-nfxy). Data: City of Chicago (chicago.gov). Data as of November 21, 2026 at 3:30 PM CT.
ScoutMyBuilding summarizes publicly available City data. It is informational only — not legal advice, not a housing inspection, and not a guarantee of current building conditions. City records may be incomplete, delayed, or inaccurate. Always verify with the City of Chicago Department of Buildings, 311, and your own walkthrough before signing a lease.
“This site provides applications using data that has been modified for use from its original source, www.cityofchicago.org, the official website of the City of Chicago. The City of Chicago makes no claims as to the content, accuracy, timeliness, or completeness of any of the data provided at this site. The data provided at this site is subject to change at any time. It is understood that the data provided at this site is being used at one’s own risk.” Required by the City of Chicago Data Terms of Use.