Free building report

1134 W Granville Ave

Winter habitability score Multiple habitability signals in public records

Download a PDF of this report

Renter reviews

Firsthand and anonymous. Renter opinions are separate from the city records below.

No renter reviews here yet. If you’ve lived at 1134 W Granville Ave, yours could be the first.

A Chicago three-flat

Do you live here?

One tap helps other renters. The full building record stays right below.

Sure, I’ll share
How’s it been living here? Required

Tap a star — 1 is rough, 5 is great.

Add more detail (optional — heat, pests, repairs, noise, management)

Tap 1 to 5 for any you want. 1 is rough, 5 is great. Skip the rest.

Heat Warm enough when it counts?
Pests Have pests been a problem?
Maintenance responsiveness When something broke, how fast did it get fixed?
Noise How noisy was it, day to day?
Management How they treated you and answered you
Would you rent here again?

Your own experience only — no fake or paid reviews. Shown anonymously after you confirm and a person approves it. Review policy · Terms

21Open City violation records
0Open heat-related City records
0311 rodent (24 mo)
2311 building (24 mo)

What rat complaints mean →

All open City violation records (21)

3 of 21 open City violation records are from the last 24 months (since November 2024), shown newest first. 18 older ones are collapsed below — still open, still counted.

  • Open

    EV1110 — MAINTAIN OR REPAIR ELECT ELEVA

    PROPERLY REPAIR AND MAINTAIN #2 PASSENGER ELEVATOR AND KEEP IN A SAFE OPERATING CONDITION. CURRENTLY OUT OF SERVICE.

  • Open

    EV1110 — MAINTAIN OR REPAIR ELECT ELEVA

    PROPERLY REPAIR AND MAINTAIN BOTH PASSENGER ELEVATORS #1 &2. KEEP IN A SAFE OPERATING CONDITION. BOTH ELEVATORS KEEP GOING OUT OF SERVICE AND ARE NOT BEING PROPERLY MAINTAINED.

  • Open

    EV1110 — MAINTAIN OR REPAIR ELECT ELEVA

    PROPERLY REPAIR AND MAINTAIN PASSENGER ELEVATOR #1 AND KEEP IN A SAFE OPERRATING CONDITION. CURRENTLY OUT OF SERVICE.

Show 18 older open City violation records (before November 2024)
  • Open

    CN101015 — REPAIR INTERIOR WALLS/CEILING

    UNIT 807 / BATHROOM AND BEDROOM CLOSET / CEILING - SMALL CRACKS IN PLASTER.

  • Open

    CN197079 — REPAIR/REPLACE SMOKE DETECTORS

    UNIT 807 / SMOKE DETECTOR - MISSING.

  • Open

    CN060001 — SUBMIT 2 COPIES CRITICAL EXAM

    SUBMIT CRITICAL EXAM REPORT FOR ENTIRE EXTERIOR OF BUILDING FOR THE EXISTING HIGH-RISE BY A REGISTERED DESIGN PROFESSIONAL. THE EXAM IS A CLOSE-UP VISUAL EXAMINATION OF THE ENTIRE EXTERIOR ENVELOPE IS TO IDENTIFYING DEFICIENCIES AND DETERMINE IF REPAIR IS REQUIRED. EXTERIOR ENVELOPE TO INCLUDE BUT NOT LIMITED TO ROOF, EXTERIOR WALLS, WINDOWS, DOORS, BALCONIES, FIRE ESCAPES, CHIMNEYS, MECHANICAL EQUIPMENT, MARQUEES, CANOPIES, SIGNS, FLAG POLES AND EXTERIOR MAINTENANCE SYSTEMS. A SIGNED AND SEALED REPORT, DETAILING THE SCOPE AND FINDINGS OF THE EXAMINATION, TOGETHER WITH RECOMMENDATIONS FOR REPAIR WHERE DEFICIENCIES ARE FOUND, SHALL BE PROVIDED TO THE OWNER, AND FILED WITH THE BUILDING DEPARTMENT. IT IS THE OWNER'S RESPONSIBILITY TO OBTAIN REQUIRED PERMITS, ACCOMPANIED BY SUPPORTING DOCUMENTS AND CONSTRUCTION DOCUMENT PLANS. THE OWNER MUST KEEP A COPY OF THE MOST RECENT REPORT, PERMIT AND CONSTRUCTION DOCUMENTS ON FILE AT THE PREMISES AND MAKE AVAILABLE FOR INSPECTION REVIEW AND APPROVAL. SEE MAINTENANCE OF HIGH-RISE EXTERIOR WALLS AND ENCLOSURES RULES AND REGULATIONS. SUBMIT TO DEPARTMENT OF BUILDINGS, ATTENTION: EXTERIOR WALL PROGRAM 3RD FLOOR, 2045 W. WASHINGTON BLVD. 60612 (14A-6-603.2 THROUGH 14A-6-603.2.6, 14A-4-401.1 AND 14A-4-411.1)

  • Open

    CN061024 — SUBMIT 2 COPY STRUCTURAL RPT

    CN061024 - SUBMIT CONDITION ASSESSMENT REPORT FOR THE PARKING GARAGE STRUCTURE, WITH NUMEROUS CRACKS AT ALL ELEVATIONS. REPORT SHALL BE SIGNED AND SEALED BY A REGISTERED DESIGN PROFESSIONAL, AND BASED ON A CRITICAL, COMPREHENSIVE, AND DETAILED PHYSICAL INSPECTION OF THE PREMISES IDENTIFIED AND DETAILED IN THE VIOLATION. THE CONDITION REPORT MUST IDENTIFY THE DATE, NATURE, SCOPE, FINDINGS, AND DEFICIENCIES OF THE INSPECTION/INVESTIGATION. THE REPORT MUST IDENTIFY EACH TECHNICAL PRINCIPLE OR STANDARD THAT IS THE BASIS OF ANY PROFESSIONAL JUDGMENT AND COMPREHENSIVE RECOMMENDATIONS FOR REPAIRS EXPRESSED IN THE REPORT. RECOMMENDATION OF REPAIRS MUST INCLUDE PHOTOS, DRAWINGS, DETAILS, AND CALCULATIONS WHICH CAN BE SUBMITTED FOR A REPAIR PERMIT IF NECESSARY. THE CONDITION REPORT, PERMIT, AND CONSTRUCTION DOCUMENTS MUST BE KEPT ON FILE AT THE PREMISES AND MADE AVAILABLE FOR FIELD INSPECTION REVIEW AND APPROVAL BY ALL RELATED TRADES. SUBMIT ELECTRONIC REPORT FOR REVIEW AND APPROVAL TO: DOB_CAR@CITYOFCHICAGO.ORG (14X-1-104.1 THRU 14X-1-104.4, 14A-6-603.5, AND 14A-4-411.1)

  • Open

    CN197087 — CARB MONOX DETECT IN RESID

    UNIT 807 / LAUNDRY ROOM / CARBON MONOXIDE DETECTOR - MISSING.

  • Open

    EV1110 — MAINTAIN OR REPAIR ELECT ELEVA

    SEAL PENETRATIONS BETWEEN MACHINE ROOM AND HOISTWAYS.

  • Open

    EV1110 — MAINTAIN OR REPAIR ELECT ELEVA

    LABEL CARTOPS AND PIT EQUIPMENT WITH CAR NUMBERS.

  • Open

    EV1110 — MAINTAIN OR REPAIR ELECT ELEVA

    CHECK FIRE SERVICE LIGHT AT PHASE 1 KEY SWITCH.

  • Open

    EV1110 — MAINTAIN OR REPAIR ELECT ELEVA

    SECURE CAB INTERIOR HAND RAILS.

  • Open

    EV1110 — MAINTAIN OR REPAIR ELECT ELEVA

    INSTALL CAUTION SIGNS ON CARTOP HAND RAILS (PINCH POINT)

  • Open

    EV1110 — MAINTAIN OR REPAIR ELECT ELEVA

    INSTALL ROPE DATA TAGS.

  • Open

    EV1110 — MAINTAIN OR REPAIR ELECT ELEVA

    TEST AUTOMATIC FIRE RECALL PRIOR TO FINAL.

  • Open

    EV1110 — MAINTAIN OR REPAIR ELECT ELEVA

    THE SWITCH FOR THE OVERHEAD MACHINE SPACE LIGHT MUST BE ACCESSIBLE FROM THE TOP LANDING.

  • Open

    EV1110 — MAINTAIN OR REPAIR ELECT ELEVA

    COVER ESCUTCHEON HOLES IN LANDING DOORS THAT ARE NO LONGER IN USE.BOTH ELEVATORS

  • Open

    EV1110 — MAINTAIN OR REPAIR ELECT ELEVA

    THE SWITCH FOR THE OVERHEAD MACHINE SPACE LIGHT MUST BE ACCESSIBLE FROM THE TOP LANDING.BOTH ELEVATORS.

  • Open

    EV1110 — MAINTAIN OR REPAIR ELECT ELEVA

    COVER ESCUTCHEON HOLES IN LANDING DOORS THAT ARE NO LONGER IN USE.

  • Open

    EV1110 — MAINTAIN OR REPAIR ELECT ELEVA

    SIGN ON MACHINE ROOM DOOR REQUIRED.

  • Open

    EV1110 — MAINTAIN OR REPAIR ELECT ELEVA

    A CURRENT FIRE SERVICE MONTHLY TEST LOG IS REQUIRED ON SITE.

About these City violation records

From the City of Chicago Building Violations dataset description: “…informational only and does not necessarily reflect the current condition of the building or property. The dataset contains cases where a respondent has been found to be liable as well as cases where the respondent has been found to be not liable.”

↑ Back to renter reviews

311 complaints (24 months)

  • building

    Building Violation

  • building

    Building Violation

Timeline

  1. Open City violation record — EV1110 MAINTAIN OR REPAIR ELECT ELEVA
  2. 311 building — Building Violation
  3. Open City violation record — EV1110 MAINTAIN OR REPAIR ELECT ELEVA
  4. Open City violation record — EV1110 MAINTAIN OR REPAIR ELECT ELEVA
  5. 311 building — Building Violation
  6. Open City violation record — CN197087 CARB MONOX DETECT IN RESID
  7. Open City violation record — CN061024 SUBMIT 2 COPY STRUCTURAL RPT
  8. Open City violation record — CN060001 SUBMIT 2 COPIES CRITICAL EXAM
  9. Open City violation record — CN197079 REPAIR/REPLACE SMOKE DETECTORS
  10. Open City violation record — CN101015 REPAIR INTERIOR WALLS/CEILING
  11. Open City violation record — EV1110 MAINTAIN OR REPAIR ELECT ELEVA
  12. Open City violation record — EV1110 MAINTAIN OR REPAIR ELECT ELEVA
  13. Open City violation record — EV1110 MAINTAIN OR REPAIR ELECT ELEVA
  14. Open City violation record — EV1110 MAINTAIN OR REPAIR ELECT ELEVA
  15. Open City violation record — EV1110 MAINTAIN OR REPAIR ELECT ELEVA
  16. Open City violation record — EV1110 MAINTAIN OR REPAIR ELECT ELEVA
  17. Open City violation record — EV1110 MAINTAIN OR REPAIR ELECT ELEVA
  18. Open City violation record — EV1110 MAINTAIN OR REPAIR ELECT ELEVA
  19. Open City violation record — EV1110 MAINTAIN OR REPAIR ELECT ELEVA
  20. Open City violation record — EV1110 MAINTAIN OR REPAIR ELECT ELEVA
  21. Open City violation record — EV1110 MAINTAIN OR REPAIR ELECT ELEVA
  22. Open City violation record — EV1110 MAINTAIN OR REPAIR ELECT ELEVA
  23. Open City violation record — EV1110 MAINTAIN OR REPAIR ELECT ELEVA

Recently closed / other violations (sample)

  • Closed / other

    EV1111 MAINTAIN OR REPAIR HYDRO ELEVA

  • Closed / other

    EV1110 MAINTAIN OR REPAIR ELECT ELEVA

  • Closed / other

    EV1110 MAINTAIN OR REPAIR ELECT ELEVA

  • Closed / other

    EV1111 MAINTAIN OR REPAIR HYDRO ELEVA

  • Closed / other

    EV1111 MAINTAIN OR REPAIR HYDRO ELEVA

  • Closed / other

    EV1110 MAINTAIN OR REPAIR ELECT ELEVA

  • Closed / other

    EV1110 MAINTAIN OR REPAIR ELECT ELEVA

  • Closed / other

    EV1111 MAINTAIN OR REPAIR HYDRO ELEVA

  • Closed / other

    EV1111 MAINTAIN OR REPAIR HYDRO ELEVA

Around 1134 W Granville Ave

Nearby buildings with open City violation records

Nearby addresses that also have open City violation records in the City of Chicago Building Violations dataset (22u3-xenr), by distance. Open each one for its current free report.

How the winter score is calculated
  1. Start at 100 (better = higher).
  2. Minus up to 40 for open heat/boiler-related building violations (12 pts each).
  3. Minus up to 45 for other open building violations (2 pts each, plus extras above 20 and 100 open).
  4. Minus up to 20 for rodent-related open violations and 311 rodent complaints (4 pts each).
  5. Minus up to 15 for recent 311 building complaints (2 pts each).
  6. Extra −10 if 3+ open heat-related violations.
  7. Chicago 311 takes no-heat complaints, but the City's public 311 dataset does not publish them as a separate type, so heat here comes from open Department of Buildings heat-related violations (codes/descriptions, e.g. CN132016 HEAT UNIT ADEQUATELY). 311 building complaints are counted separately, not as heat.
  8. Public records only — not an inspection, appraisal, or legal advice.

Sources: City of Chicago Building Violations (data.cityofchicago.org/d/22u3-xenr); City of Chicago 311 Service Requests (data.cityofchicago.org/d/v6vf-nfxy). Data: City of Chicago (chicago.gov). Data as of November 21, 2026 at 12:48 PM CT.

ScoutMyBuilding summarizes publicly available City data. It is informational only — not legal advice, not a housing inspection, and not a guarantee of current building conditions. City records may be incomplete, delayed, or inaccurate. Always verify with the City of Chicago Department of Buildings, 311, and your own walkthrough before signing a lease.

“This site provides applications using data that has been modified for use from its original source, www.cityofchicago.org, the official website of the City of Chicago. The City of Chicago makes no claims as to the content, accuracy, timeliness, or completeness of any of the data provided at this site. The data provided at this site is subject to change at any time. It is understood that the data provided at this site is being used at one’s own risk.” Required by the City of Chicago Data Terms of Use.

Check another address

Help: hello@scoutmybuilding.com