Free building report
1115 W Oakdale Ave
Winter habitability score Multiple habitability signals in public records
Renter reviews
Firsthand and anonymous. Renter opinions are separate from the city records below.
No renter reviews here yet. If you’ve lived at 1115 W Oakdale Ave, yours could be the first.
Do you live here?
One tap helps other renters. The full building record stays right below.
Thanks for looking. The full record is right below.
No problem. The full record is right below.
Thanks, neighbor. Share how it’s really been — one tap on the stars is all it takes.
Thanks. Share how it really was — one tap on the stars is all it takes.
Sure, I’ll share
All open City violation records (18)
4 of 18 open City violation records are from the last 24 months (since November 2024), shown newest first. 14 older ones are collapsed below — still open, still counted.
- Open
CN061014 — REPAIR EXTERIOR WALL
FRONT ELEVATION AND COURTYARD ELEVATIONS /EXTERIOR WALL - MASONRY DEFLECTIONS AT MULTIPLE LOCATIONS; LOOSE, CRUMBLING MORTAR AT VARIOUS LOCATIONS ESPECIALLY NEAR WINDOW LOCATIONS. EAST ELEVATION /EXTERIOR WALL - STEP FRACTURES. (14X-3-303.6)
- Open
CN190029 — ARRANGE FOR REINSPECTION REGAR
INTERIOR OF BUILDING - NO RESPONSE. UNVERIFIED DETECTORS AND CONDITIONS. UNABLE TO INSPECT INTERIOR STAIRWAY SYSTEMS. (14A-1-104.7)
- Open
CN065014 — REPAIR LINTELS
FRONT ELEVATION /LINTELS AT GRADE - RUSTED AND SAGGING; GAPS AT TOP PACKED WITH EXCESSIVE AMOUNT OF MORTAR. PLANS AND PERMIT REQUIRED FOR LINTEL REPLACEMENT OVER 6FT. ALL WORK SUBJECT TO FIELD INSPECTION AND APPROVAL.
- Open
CN065034 — REPAIR WINDOW SILLS
EAST ELEVATION /WINDOW SILLS - OPEN MORTAR JOINTS. (14X-3-303.13)
Show 14 older open City violation records (before November 2024)
- Open
CN070024 — REPAIR PORCH SYSTEM
THIS WRITE UP APPLIES FOR ALL (3) THREE PORCH(S) COLUMNS ERECTED ON TOP OF CONCRETE SLAB, WITH NO BASES: FOUNDATION STATUS UNKNOWN, SOME FOUNDATION BASES FORM BY POURING CONCRETE IN AROUND COLUMNS. COLUMNS ARE OUT OF PLUMB, BOWING AND TWISTING, COLUMNS HAVE INADEQUATE HALF - LAP JOINTS FASTENED WITH ( 2 ) 1/4¿ BOLTS ONLY SPLICE IS LESS THE 12¿, 4X4 COLUMNS HAVE INADEQUATE HALF-LAP JOINTS FASTENED WITH NAILS ONLY, LEDGER BEAMS FASTENED TO BUILDING EXTERIOR WALLS WITH NAILS ONLY, UPPER AND LOWER STAIR STRINGERS INADEQUATELY SUPPORTED AT HEADER JOIST, AT ROOF CONNECTION BETWEEN BEAM AND COLUMN CONNECTIONS ARE MISSING STEEL ANGLES - BRACKETS, - GUARD RAILS ARE LESS THEN 42" IN HEIGHT, THIS IS A PARTIAL INSPECTION ONLY, UNABLE TO PERFORM A FULL INSPECTION TO ALL THREE (3) PORCH(S) SINCE THEY ARE FENCE.
- Open
CN190029 — ARRANGE FOR REINSPECTION REGAR
INTERIOR OF BUILDING - NO RESPONSE, UNVERIFIED DETECTORS OCCUPANCY AND CONDITIONS.UNABLE TO INSPECT PORCH(S) PARTIAL INSPECTION DONE FROM ALLEY , - UNABLE TO GAIN ENTRY, FRONT SECURITY DOOR, REAR IRON GATE, UNABLE TO PERFORM 2016 ANNUAL INSPECTION
- Open
CN061014 — REPAIR EXTERIOR WALL
1115 W - NORTH COURT YARD - AT 3RD - LOOSE AND SHIFTING STONE SECTIONS WITH WASHED OUT MORTAR ABOVE WINDOWS. EAST WALL UNDER WINDOWS - WASHED OUT MORTAR WITH STEP CRACKS.
- Open
CN063014 — CHIMNEY
SOUTH CHIMNEY - WASHED OUT MORTAR.
- Open
CN138106 — STOP/REMOVE NUISANCE
SOUTHEAST PORCH UNDER STAIRS - ACCUMULATION OF BRICKS 2' TO 3' HIGH.
- Open
CN065034 — REPAIR WINDOW SILLS
EAST STONE WINDOW SILLS - WASHED OUT MORTAR.
- Open
CN073014 — REPAIR EXTERIOR DOOR
1125 W ENTRY DOOR - RUBS SILL WITH LOOSE FRAME SECTION ON INTERIOR AT HEAD WITH LOOSE CLOSER.
- Open
CN070024 — REPAIR PORCH SYSTEM
4 - 3 STORY OPEN WOOD PORCHES AT REAR OF BUILDING - COLUMNS ERECTED ON CONCRETE SLABS AND CONCRETE BASES - FOUNDATIONS UNKNOWN. SOME BEAMS ONLY NAILED TO COLUMNNS. 6 X 6 BEAM COLUMN NOTCHES AND 2 X 8 RIM JOISTS COLUMN NOTCHES IN CLOSE PROXIMITY OF EACH OTHER . SOME 2 X 8 DECK JOISTS SPAN 14' TO 16' . STRINGERS ONLY NAILED TO HEADER JOISTS AND COLUMNS. GUARDRAILS AND HANDRAILS ONLY NAILED TO COLUMNS AND BUILDING. PLANS AND PERMIT REQUIRED FOR PORCH REPAIRS.
- Open
CN106015 — REPAIR INTERIOR STAIR SYSTEM
1127 W - FRONT INTERIOR STAIRWAY AT 3RD - GUARDRAIL - MISSING BALUSTERS . 1ST TO 3RD LEVEL - HANDRAILS - LOOSE AND BROKEN BALUSTERS.
- Open
CN190019 — ARRANGE PREMISE INSPECTION
BUILDING INTERIOR - NO RESPONSE - UNVERIFIED DETECTORS AND CONDITIONS. UNABLE TO INSPECT ALL INTERIOR STAIRWAYS OR VERIFY COMPLAINT OF BUGS AND RODENTS.
- Open
CN198019 — FILE BLDG REGISTRATION
BUILDING NOT REGISTERED FROM 2008 THROUGH 2013.
- Open
CN196029 — POST OWNER/MANAGERS NAME/#
BUILDING OWNER'S ID SIGN - INCOMPLETE INFORMATION - MAILING ADDRESS - MISSING.
- Open
CN076034 — REPAIR GUTTER
EAST GUTTER - BENT.
- Open
CN070024 — REPAIR PORCH SYSTEM
REAR PORCH & EXTERIOR STAIR SYSTEMS WITH STRINGERS NOT BOLTED TO WALL 7 POSTS .2.GUARD RAILS LOW, UNDER 36".3.FRONT HEADER HOISTS NOT BOLTED
About these City violation records
From the City of Chicago Building Violations dataset description: “…informational only and does not necessarily reflect the current condition of the building or property. The dataset contains cases where a respondent has been found to be liable as well as cases where the respondent has been found to be not liable.”
311 complaints (24 months)
- rodent
Rodent Baiting/Rat Complaint
- rodent
Rodent Baiting/Rat Complaint
- building
Building Violation
Timeline
- 311 rodent — Rodent Baiting/Rat Complaint
- Open City violation record — CN065034 REPAIR WINDOW SILLS
- Open City violation record — CN065014 REPAIR LINTELS
- Open City violation record — CN190029 ARRANGE FOR REINSPECTION REGAR
- Open City violation record — CN061014 REPAIR EXTERIOR WALL
- 311 rodent — Rodent Baiting/Rat Complaint
- 311 building — Building Violation
- Open City violation record — CN190029 ARRANGE FOR REINSPECTION REGAR
- Open City violation record — CN070024 REPAIR PORCH SYSTEM
- Open City violation record — CN076034 REPAIR GUTTER
- Open City violation record — CN196029 POST OWNER/MANAGERS NAME/#
- Open City violation record — CN198019 FILE BLDG REGISTRATION
- Open City violation record — CN190019 ARRANGE PREMISE INSPECTION
- Open City violation record — CN106015 REPAIR INTERIOR STAIR SYSTEM
- Open City violation record — CN070024 REPAIR PORCH SYSTEM
- Open City violation record — CN073014 REPAIR EXTERIOR DOOR
- Open City violation record — CN065034 REPAIR WINDOW SILLS
- Open City violation record — CN138106 STOP/REMOVE NUISANCE
- Open City violation record — CN063014 CHIMNEY
- Open City violation record — CN061014 REPAIR EXTERIOR WALL
- Open City violation record — CN070024 REPAIR PORCH SYSTEM
Recently closed / other violations (sample)
- Closed / other
CN070024 REPAIR PORCH SYSTEM
- Closed / other
CN061014 REPAIR EXTERIOR WALL
- Closed / other
CN190029 ARRANGE FOR REINSPECTION REGAR
- Closed / other
CN190029 ARRANGE FOR REINSPECTION REGAR
- Closed / other
CN104055 REPUTTY WINDOW PANES
- Closed / other
CN061034 FLAKY INTERIOR PAINT
Around 1115 W Oakdale Ave
- Lake View building violations and 311 complaints
- DePaul off-campus housing: Lakeview and Lincoln Park renter guide
Nearby buildings with open City violation records
Nearby addresses that also have open City violation records in the City of Chicago Building Violations dataset (22u3-xenr), by distance. Open each one for its current free report.
How the winter score is calculated
- Start at 100 (better = higher).
- Minus up to 40 for open heat/boiler-related building violations (12 pts each).
- Minus up to 45 for other open building violations (2 pts each, plus extras above 20 and 100 open).
- Minus up to 20 for rodent-related open violations and 311 rodent complaints (4 pts each).
- Minus up to 15 for recent 311 building complaints (2 pts each).
- Extra −10 if 3+ open heat-related violations.
- Chicago 311 takes no-heat complaints, but the City's public 311 dataset does not publish them as a separate type, so heat here comes from open Department of Buildings heat-related violations (codes/descriptions, e.g. CN132016 HEAT UNIT ADEQUATELY). 311 building complaints are counted separately, not as heat.
- Public records only — not an inspection, appraisal, or legal advice.
Sources: City of Chicago Building Violations (data.cityofchicago.org/d/22u3-xenr); City of Chicago 311 Service Requests (data.cityofchicago.org/d/v6vf-nfxy). Data: City of Chicago (chicago.gov). Data as of November 21, 2026 at 12:37 PM CT.
ScoutMyBuilding summarizes publicly available City data. It is informational only — not legal advice, not a housing inspection, and not a guarantee of current building conditions. City records may be incomplete, delayed, or inaccurate. Always verify with the City of Chicago Department of Buildings, 311, and your own walkthrough before signing a lease.
“This site provides applications using data that has been modified for use from its original source, www.cityofchicago.org, the official website of the City of Chicago. The City of Chicago makes no claims as to the content, accuracy, timeliness, or completeness of any of the data provided at this site. The data provided at this site is subject to change at any time. It is understood that the data provided at this site is being used at one’s own risk.” Required by the City of Chicago Data Terms of Use.