All open City violation records (13)
No open City violation records dated in the last 24 months (since November 2024). The newest open one is from September 17, 2018. All 13 are collapsed below — still open, still counted.
Show 13 older open City violation records (before November 2024)
- Open
CN190029 — ARRANGE FOR REINSPECTION REGAR
INTERIOR OF BUILDING /MOST APTS. - NO RESPONSE. UNABLE TO VERIFY DETECTORS AND CONDITIONS.
- Open
CN074014 — SERVICE WALK, PASSAGE, AREAWAY
REAR CATWALK - RUSTED.
- Open
CN070014 — REPAIR EXTERIOR STAIR
REAR EXTERIOR STAIRS /GRADE TO BASEMENT - RUSTED.
- Open
CN065034 — REPAIR WINDOW SILLS
SOUTH ELEVATION /STONE WINDOW SILLS - FRACTURED, BROKEN, WITH SECTIONS MISSING.
- Open
CN063014 — CHIMNEY
SOUTH ELEVATION /CHIMNEY - SPALLED BRICKS, WITH WASHED OUT MORTAR.
- Open
CN061014 — REPAIR EXTERIOR WALL
SOUTH EXTERIOR WALL @ 3RD FLOOR - SPALLED BRICKS, WITH WASHED OUT MORTAR.NORTH EXTERIOR WALL @ GRADE - CRACKED CONCRETE, WITH WASHED OUT MORTAR.
- Open
CN190019 — ARRANGE PREMISE INSPECTION
INTERIOR OF THE BUILDING - NO RESPONSE, UNVERIFIED DETECTORS AND CONDITIONS. REAR YARD - LOCKED GATES, UNABLE TO INSPECT REAR PORCH.
- Open
VT1010 — ARRANGE COMPLETED PERMIT INSP.
- Open
NC1020 — CONTRARY TO PLANS/OUT OF SCOPE
SR#08-00283872 REMOVE WORK CONTRARY TO APPROVED PLANS AND PERMITS BY LANDMARKS DEPARTMENT AND BUILDING DEPARTMENT INSTALLED VINYL UNAPPROVED WINDOWS ON ALL FLOOR LEVELS ON EAST AND NORTH ELEVATIONS OF LANDMARKED BUILDING
- Open
NC1010 — CONTRARY TO ORIGINAL PLAN
REMOVE WORK CONTRARY TO ORIGINAL PLANS AND CONSTRUCTION (PERMITS) FOR LANDMARKED BUILDING REMOVED LANDMARKED WINDOWS ON ALL FLOOR LEVELS ON EAST AND NORTH ELEVATIONS (NOTE: OWNER SHOULD CONTACT LANDMARKS DEPT., MS. DIJANA CUVALO, 312-744-3238)
- Open
CN070024 — REPAIR PORCH SYSTEM
REAR PORCH SYSTEM - NO VISIBLE FOUNDATION, EXCESSIVE GAP BETWEEN BOLTS AT LEDGERS, DEFICIENT BEAM TO COLUMN CONNECTION, BUTTED COLUMN UPRIGHTS & BOWED, RAILINGS TO LOW & LOOSE & EXCESSIVE STAIRCASE LENGTH FROM GRADE TO 2ND FLOOR.
- Open
199029 — OPEN TYPE VIOLATION
FAILURE TO PERMIT ACCESS FOR ANNUAL INSPECTION 13-20-020. ATTEMPTED INSPECTION 03/24/06. STICKER LEFT ON DOOR. NO ONE CONTACTED DEPT OF BUILDINGS TO ALLOW ACCESS. TO ARRANGE INSPECTION PLEASE CALL (312) 746 - 9797.
- Open
CN104015 — REPLCE WINDOW PANES, PLEXGLAS
FRONT PLATE GLASS WINDOWS - BROKEN & BOARDED.
About these City violation records
From the City of Chicago Building Violations dataset description: “…informational only and does not necessarily reflect the current condition of the building or property. The dataset contains cases where a respondent has been found to be liable as well as cases where the respondent has been found to be not liable.”
311 complaints (24 months)
No matching 311 complaints in the last 24 months.
Timeline
- Open City violation record — CN061014 REPAIR EXTERIOR WALL
- Open City violation record — CN063014 CHIMNEY
- Open City violation record — CN065034 REPAIR WINDOW SILLS
- Open City violation record — CN070014 REPAIR EXTERIOR STAIR
- Open City violation record — CN074014 SERVICE WALK, PASSAGE, AREAWAY
- Open City violation record — CN190029 ARRANGE FOR REINSPECTION REGAR
- Open City violation record — CN190019 ARRANGE PREMISE INSPECTION
- Open City violation record — VT1010 ARRANGE COMPLETED PERMIT INSP.
- Open City violation record — NC1010 CONTRARY TO ORIGINAL PLAN
- Open City violation record — NC1020 CONTRARY TO PLANS/OUT OF SCOPE
- Open City violation record — CN104015 REPLCE WINDOW PANES, PLEXGLAS
- Open City violation record — 199029 OPEN TYPE VIOLATION
- Open City violation record — CN070024 REPAIR PORCH SYSTEM
Recently closed / other violations (sample)
- Closed / other
CN077014 REPAIR FENCE
- Closed / other
CN131016 SCREEN OUTER DOORS, WINDOWS
- Closed / other
CN077014 REPAIR FENCE
- Closed / other
CN131016 SCREEN OUTER DOORS, WINDOWS
- Closed / other
VT1010 ARRANGE COMPLETED PERMIT INSP.
- Closed / other
VT1010 ARRANGE COMPLETED PERMIT INSP.
- Closed / other
CN064014 REPAIR CORNICE
- Closed / other
CN196029 POST OWNER/MANAGERS NAME/#
- Closed / other
CN198019 FILE BLDG REGISTRATION
- Closed / other
CN060002 PROVIDE SIDEWALK SHED F/PROTCT
- Closed / other
CN190019 ARRANGE PREMISE INSPECTION
- Closed / other
NC1010 CONTRARY TO ORIGINAL PLAN
- Closed / other
NC1020 CONTRARY TO PLANS/OUT OF SCOPE
- Closed / other
NC2071 WORK NOT ALLOWED
- Closed / other
NC2011 PLANS & PERMITS REQ - CONTRCTR
- Closed / other
CN199029
- Closed / other
199029 OPEN TYPE VIOLATION
- Closed / other
NC2011 PLANS & PERMITS REQ - CONTRCTR
- Closed / other
199029 OPEN TYPE VIOLATION
- Closed / other
CN061014 REPAIR EXTERIOR WALL
- Closed / other
CN104015 REPLCE WINDOW PANES, PLEXGLAS
Around 1056 N Damen Ave
Nearby buildings with open City violation records
Nearby addresses that also have open City violation records in the City of Chicago Building Violations dataset (22u3-xenr), by distance. Open each one for its current free report.
How the winter score is calculated
- Start at 100 (better = higher).
- Minus up to 40 for open heat/boiler-related building violations (12 pts each).
- Minus up to 45 for other open building violations (2 pts each, plus extras above 20 and 100 open).
- Minus up to 20 for rodent-related open violations and 311 rodent complaints (4 pts each).
- Minus up to 15 for recent 311 building complaints (2 pts each).
- Extra −10 if 3+ open heat-related violations.
- Chicago 311 takes no-heat complaints, but the City's public 311 dataset does not publish them as a separate type, so heat here comes from open Department of Buildings heat-related violations (codes/descriptions, e.g. CN132016 HEAT UNIT ADEQUATELY). 311 building complaints are counted separately, not as heat.
- Public records only — not an inspection, appraisal, or legal advice.
Sources: City of Chicago Building Violations (data.cityofchicago.org/d/22u3-xenr); City of Chicago 311 Service Requests (data.cityofchicago.org/d/v6vf-nfxy). Data: City of Chicago (chicago.gov). Data as of November 22, 2026 at 2:24 AM CT.
ScoutMyBuilding summarizes publicly available City data. It is informational only — not legal advice, not a housing inspection, and not a guarantee of current building conditions. City records may be incomplete, delayed, or inaccurate. Always verify with the City of Chicago Department of Buildings, 311, and your own walkthrough before signing a lease.
“This site provides applications using data that has been modified for use from its original source, www.cityofchicago.org, the official website of the City of Chicago. The City of Chicago makes no claims as to the content, accuracy, timeliness, or completeness of any of the data provided at this site. The data provided at this site is subject to change at any time. It is understood that the data provided at this site is being used at one’s own risk.” Required by the City of Chicago Data Terms of Use.